Privacy and Security Notice

End_of_Run_25266


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 13:48:00 on November 6, 2009

    Entry number 297821

    keyword=End_of_Run_25266
    ****************************
     Run Number: 25266
     End of Run Comment:
    Run_type=Pedestal,target_type=LD2, 20cm,targetpol_poldir=Longitudinal,targetpol_pol=87,beam_e0=6.0,beam_raster=off,beam_current=0.0,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=19.0,rightarm_sieve=out,comment_text=ped run on L-HRS, normal config
     
    
    PRESCALE FACTORS:ps1=9999   ps2=99999   ps3=99999   ps4=99999   ps5=65535   ps6=65535   ps7=65535   ps8=2   
    
    EVENTS   : [0]: 23185        
    TIME     : [0]: 0.902 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  16.34%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 0.0/6.3  Hz   T2[0] : 0.0/5.7  Hz   T3[0] : 0.0/1.4  Hz   T4[0] : 0.0/0.3  Hz   T5[0] : 0.0/103.4 Hz   T6[0] : 0.0/100.0 Hz   T7[0] : 0.1/5436.6 Hz   T8[0] :512.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :      0/339      T2[0] :      0/308      T3[0] :      0/76       T4[0] :      0/15       T5[0] :      0/5595     T6[0] :      0/5411     T7[0] :      4/294222   T8[0] :  27709/55418    
    
    AVERAGE CURRENT
    BCM x1 : 0.0033 uA  BCM x3 : -0.0320uA  BCM x10: 0.0036 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:2.242E-07      BCM u3 [0]:-2.552E-06     BCM u10[0]:4.505E-07      
    
    BCM d1 [0]:1.357E-07      BCM d3 [0]:-9.121E-07     BCM d10[0]:-6.611E-08     
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 25266 at Fri Nov 6 13:47:57 EST 2009
    
    Left Arm Top VDC Current : 1.41602
    Left Arm Bottom VDC Current : 1.41602
    Left Arm Top VDC voltage : 0.0180664
    Left Arm Bottom VDC voltage : 0.0180664
    -----
    Right Arm Top VDC Current : -1.5625
    Right Arm Bottom VDC Current : -1.41602
    Right Arm Top VDC voltage : -0.0102539
    Right Arm Bottom VDC voltage : -0.0107422
    -----
    Left Arm Q1 momentum : 3.66029
    Left Arm Q1 power supply : 2753.8
    Left Arm Q1 gauss meter : -0.23216
    Left Arm Q2 gauss meter : 0.8273
    Left Arm Q2 power supply current : 1575.84
    Left Arm Q2 momentum : 3.65964
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.22
    Left Arm D1 momentum : 3.66004
    Left Arm D1 NMR : 1.35576
    Left Arm arm angle : 12.8988
    Left Arm Q3 gauss meter : -0.73461
    Left Arm Q3 power supply current : 1457.21
    Left Arm Q3 momentum : 3.66024
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 2.35968
    Right Arm Q1 power supply : 1774.38
    Right Arm Q1 gauss meter : -0.04407
    Right Arm Q2 power supply current : 299.026
    Right Arm Q2 momentum : 0.69481
    Right Arm Q2 gauss meter : 0.156
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 50.586
    Right Arm D1 momentum : 0.0488513
    Right Arm D1 NMR : 1.43183
    Right Arm arm angle : 20.001
    Right Arm Q3 power supply current : 1212.29
    Right Arm Q3 momentum : 3.0301
    Right Arm Q3 gauss meter : 0.5359
    Right Arm Q3 power supply polarity : disabled
    -----
    Average current of the two cavities : 0.0257545
    Current on Unser monitor : 16.8912
    Current on Upstream bcm : 0.0374384
    Current on Downstream bcm : 0.0140706
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 0.149065
    Hall C Current : 0
    MBSY1c magnet current (amp) : 0.0377197
    MBSY1c Bdl : 1.51764e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.46
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6067.46
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 0.0548645
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Wien angle : 74.7279
    Wien BDL : 1724.8
    Wien field : 49.796
    Laser attenuation Hall A : 60
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    -----
    Target : Empty
    fan frequency loop 1 : 59.5
    fan frequency loop 3 : 0
    Encoder position : 3.20255e+06
    Target type : 3.20255e+06
    temperature loop 1(1) : 21.99
    temperature loop 1(2) : 21.95
    temperature loop 1(3) : 22.26
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.5
    Heat exchange LH2 : 275.3
    HPH H2 loop 1 : 1090.44
    HPH H2 loop 3 : 0.011068