Privacy and Security Notice

End_of_Run_25270


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 22:19:26 on November 6, 2009

    Entry number 297892

    keyword=End_of_Run_25270
    ****************************
     Run Number: 25270
     End of Run Comment:
    Run_type=Check out,target_type=No Target, Empty,targetpol_poldir=Longitudinal,targetpol_pol=87,beam_e0=6.0,beam_raster=off,beam_current=0.0,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=19.0,rightarm_sieve=out,comment_text=detector check out
     
    
    PRESCALE FACTORS:ps1=1   ps2=99999   ps3=99999   ps4=99999   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 88695        
    TIME     : [0]: 85.709 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:   6.86%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :18.4/18.4 Hz   T2[0] : 0.0/9.3  Hz   T3[0] : 0.0/1.8  Hz   T4[0] : 0.0/0.9  Hz   T5[0] : 0.0/102.9 Hz   T6[0] : 0.0/2.0  Hz   T7[0] : 0.1/4556.5 Hz   T8[0] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  94803/94803    T2[0] :      0/47804    T3[0] :      0/9169     T4[0] :      0/4799     T5[0] :      8/528951   T6[0] :      0/10506    T7[0] :    357/23431880  T8[0] :     80/5265933  
    
    AVERAGE CURRENT
    BCM x1 : 0.8839 uA  BCM x3 : -0.0312uA  BCM x10: 0.8959 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.004519       BCM u3 [0]:-0.0002339     BCM u10[0]:0.00459        
    
    BCM d1 [0]:0.004572       BCM d3 [0]:-8.667E-05     BCM d10[0]:0.004624       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 25270 at Fri Nov 6 22:19:22 EST 2009
    Left Arm Q1 momentum : 3.66043
    
    Left Arm Q1 power supply : 2753.86
    Left Arm Top VDC Current : 3.85742
    Left Arm Q2 gauss meter : 0.8273
    Left Arm Bottom VDC Current : 4.24805
    Left Arm Q2 power supply current : 1575.84
    Left Arm Top VDC voltage : 4
    Left Arm Q2 momentum : 3.65963
    Left Arm Bottom VDC voltage : 4.00049
    -----
    Left Arm Q2 power supply polarity : disabled
    Right Arm Top VDC Current : -14.2578
    Left Arm D1 power supply current : 1325.22
    Right Arm Bottom VDC Current : 0.0976562
    Left Arm D1 momentum : 3.66008
    Right Arm Top VDC voltage : 4.00195
    Left Arm D1 NMR : 1.35577
    Right Arm Bottom VDC voltage : 4.00977
    -----
    Left Arm arm angle : 12.8988
    Left Arm Q1 momentum : 3.66043
    Left Arm Q3 gauss meter : -0.73458
    Left Arm Q1 power supply : 2753.86
    Left Arm Q3 power supply current : 1457.2
    Left Arm Q1 gauss meter : -0.23217
    Left Arm Q2 gauss meter : 0.8273
    Left Arm Q3 momentum : 3.66022
    Left Arm Q2 power supply current : 1575.84
    Left Arm Q3 power supply polarity : disabled
    -----
    Left Arm Q2 momentum : 3.65963
    Right Arm Q1 momentum : 2.62972
    Left Arm Q2 power supply polarity : disabled
    Right Arm Q1 power supply : 1977.38
    Left Arm D1 power supply current : 1325.22
    Right Arm Q1 gauss meter : -0.04911
    Left Arm D1 momentum : 3.66008
    Right Arm Q2 power supply current : 1132.11
    Left Arm D1 NMR : 1.35577
    Right Arm Q2 momentum : 2.63057
    Left Arm arm angle : 12.8988
    Left Arm Q3 gauss meter : -0.73458
    Right Arm Q2 gauss meter : 0.5925
    Left Arm Q3 power supply current : 1457.2
    Right Arm Q2 power supply polarity : enabled
    Left Arm Q3 momentum : 3.66022
    Right Arm D1 power supply current : 932.84
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm D1 momentum : 2.62998
    Right Arm Q1 momentum : 2.62972
    Right Arm D1 NMR : 0.975955
    Right Arm Q1 power supply : 1977.38
    Right Arm arm angle : 20.001
    Right Arm Q1 gauss meter : -0.04911
    Right Arm Q3 power supply current : 1046.64
    Right Arm Q2 power supply current : 1132.11
    Right Arm Q3 momentum : 2.63036
    Right Arm Q2 momentum : 2.63057
    Right Arm Q3 gauss meter : 0.4684
    Right Arm Q2 gauss meter : 0.5925
    Right Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q2 power supply polarity : enabled
    Average current of the two cavities : 5.17128
    Right Arm D1 power supply current : 932.841
    Current on Unser monitor : 23.8241
    Current on Upstream bcm : 5.03535
    Right Arm D1 momentum : 2.62998
    Current on Downstream bcm : 5.3072
    Right Arm D1 NMR : 0.975955
    Upstream Cavity Coefficient : 42.6
    Right Arm arm angle : 20.001
    Downstream Cavity Coefficient : 43.8
    Right Arm Q3 power supply current : 1046.64
    Current on IBC0L02 (source) : 5.31894
    Right Arm Q3 momentum : 2.63036
    Hall C Current : 0
    Right Arm Q3 gauss meter : 0.4684
    MBSY1c magnet current (amp) : 254.343
    Right Arm Q3 power supply polarity : disabled
    -----
    MBSY1c Bdl : 1.51764e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6066.56
    Average current of the two cavities : 5.17128
    Hall A momentum orbit correction (dpp) : -0.000147764
    Current on Unser monitor : 23.8241
    Hall A setup momentum (MMSHLAE) : 6067.5
    Current on Upstream bcm : 5.03535
    Current on Downstream bcm : 5.3072
    Hall A energy (halla_MeV) : 6066.56
    Hall C energy (hallc_MeV) : 6070.48
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 5.29999
    Hall C Current : 0
    MBSY1c magnet current (amp) : 254.343
    MBSY1c Bdl : 1.51764e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6066.56
    Delta(E)/E width (MV_AI_DXWID) : 0.0548634
    Hall A momentum orbit correction (dpp) : -0.000147764
    IPM1C12.XPOS : 0.539449
    Hall A setup momentum (MMSHLAE) : 6067.5
    IPM1H04A.XPOS : -1.90382
    Hall A energy (halla_MeV) : 6066.56
    IPM1H04A.YPOS : 1.35392
    IPM1H04B.XPOS : -3.01642
    IPM1H04B.YPOS : 1.63685
    -----
    Hall C energy (hallc_MeV) : 6070.48
    Wien angle : 74.7279
    Wien BDL : 1724.8
    Wien field : 49.796
    Laser attenuation Hall A : 65
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Delta(E)/E width (MV_AI_DXWID) : 0.0548634
    Beam Half-wave plate (off=out) : OUT
    -----
    IPM1C12.XPOS : 0.537596
    Helicity Settle Read : 500
    IPM1H04A.XPOS : -1.90903
    Helicity Delay Read : 8 cycles
    IPM1H04A.YPOS : 1.34641
    Helicity Pattern : Quartet
    -----
    IPM1H04B.XPOS : -3.0158
    Target : Carbon Hole
    IPM1H04B.YPOS : 1.6417
    -----
    fan frequency loop 1 : 60
    Wien angle : 74.7279
    Wien BDL : 1724.8
    fan frequency loop 3 : 0
    Wien field : 49.796
    Encoder position : 9.05468e+06
    Laser attenuation Hall A : 65
    Target type : 9.05468e+06
    Laser power Hall A : 100
    temperature loop 1(1) : 21.99
    Half-wave plate (off=out) : OUT
    temperature loop 1(2) : 21.95
    rotating waveplate : 1200
    temperature loop 1(3) : 22.28
    Beam Half-wave plate (off=out) : OUT
    -----
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    Helicity Settle Read : 500
    temperature loop 3(3) : 29.99
    Helicity Delay Read : 8 cycles
    Heat exchange LH2 : 24.5
    Helicity Pattern : Quartet
    -----
    Heat exchange LH2 : 274.8
    Target : Carbon Hole
    HPH H2 loop 1 : 1008.38
    fan frequency loop 1 : 59.5
    HPH H2 loop 3 : 0.00293052
    fan frequency loop 3 : 0
    Encoder position : 9.05468e+06
    Target type : 9.05468e+06
    temperature loop 1(1) : 21.99
    temperature loop 1(2) : 21.95
    temperature loop 1(3) : 22.28
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.5
    Heat exchange LH2 : 274.9
    HPH H2 loop 1 : 1008.38
    HPH H2 loop 3 : 0.00293052