Privacy and Security Notice

End_of_Run_4816


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 22:23:50 on November 6, 2009

    Entry number 297897

    keyword=End_of_Run_4816
    ****************************
     Run Number: 4816
     End of Run Comment:
    Run_type=Check out,target_type=Holey C12,targetpol_poldir=Longitudinal,targetpol_pol=87,beam_e0=6.0,beam_raster=off,beam_current=0.0,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=19.0,rightarm_sieve=out,comment_text=detector check out
     
    
    PRESCALE FACTORS:ps1=1   ps2=16777215   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 40649        
    TIME     : [0]: 4.201 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  52.05%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :336.3/336.3 Hz   T2[0] : 0.0/17.4 Hz   T3[0] : 0.0/23.0 Hz   T4[0] : 0.0/19.6 Hz   T5[0] : 0.0/25.5 Hz   T6[0] : 0.0/12.7 Hz   T7[0] : 0.1/6833.8 Hz   T8[0] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  84752/84752    T2[0] :      0/4378     T3[0] :      0/5805     T4[0] :      0/4940     T5[0] :      0/6419     T6[0] :      0/3210     T7[0] :     26/1722336  T8[0] :      3/258080   
    
    AVERAGE CURRENT
    BCM x1 : 2.3703 uA  BCM x3 : 0.4360 uA  BCM x10: 2.4650 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:-3.851E-05     BCM u3 [0]:0.000224       BCM u10[0]:-4.792E-06     
    
    BCM d1 [0]:0.001233       BCM d3 [0]:-4.248E-06     BCM d10[0]:0.001247       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4816 at Fri Nov 6 22:23:47 EST 2009
    Left Arm Q3 power supply current : 1457.2
    
    Left Arm Q3 momentum : 3.66021
    Left Arm Top VDC Current : 4.29688
    Left Arm Q3 power supply polarity : disabled
    -----
    Left Arm Bottom VDC Current : 4.49219
    Right Arm Q1 momentum : 2.62972
    Left Arm Top VDC voltage : 4.00146
    Right Arm Q1 power supply : 1977.38
    Left Arm Bottom VDC voltage : 4.00098
    -----
    Right Arm Q1 gauss meter : -0.0491
    Right Arm Top VDC Current : -17.5293
    Right Arm Q2 power supply current : 1132.11
    Right Arm Bottom VDC Current : 1.17188
    Right Arm Q2 momentum : 2.63057
    Right Arm Top VDC voltage : 4.00635
    Right Arm Q2 gauss meter : 0.5924
    Right Arm Bottom VDC voltage : 4
    -----
    Right Arm Q2 power supply polarity : enabled
    Left Arm Q1 momentum : 3.66036
    Right Arm D1 power supply current : 932.84
    Left Arm Q1 power supply : 2753.86
    Left Arm Q1 gauss meter : -0.23215
    Right Arm D1 momentum : 2.62998
    Left Arm Q2 gauss meter : 0.8273
    Right Arm D1 NMR : 0.975955
    Left Arm Q2 power supply current : 1575.83
    Right Arm arm angle : 20.001
    Left Arm Q2 momentum : 3.65963
    Right Arm Q3 power supply current : 1046.64
    Left Arm Q2 power supply polarity : disabled
    Right Arm Q3 momentum : 2.63035
    Left Arm D1 power supply current : 1325.22
    Right Arm Q3 gauss meter : 0.4684
    Left Arm D1 momentum : 3.66008
    Right Arm Q3 power supply polarity : disabled
    -----
    Left Arm D1 NMR : 1.35577
    Average current of the two cavities : 5.16493
    Left Arm arm angle : 12.8988
    Current on Unser monitor : 22.4151
    Left Arm Q3 gauss meter : -0.73458
    Current on Upstream bcm : 5.04567
    Current on Downstream bcm : 5.2842
    Left Arm Q3 power supply current : 1457.2
    Upstream Cavity Coefficient : 42.6
    Left Arm Q3 momentum : 3.66021
    Downstream Cavity Coefficient : 43.8
    Left Arm Q3 power supply polarity : disabled
    -----
    Current on IBC0L02 (source) : 5.33796
    Right Arm Q1 momentum : 2.62972
    Hall C Current : 0
    Right Arm Q1 power supply : 1977.38
    MBSY1c magnet current (amp) : 254.343
    Right Arm Q1 gauss meter : -0.04909
    MBSY1c Bdl : 1.51764e+06
    Right Arm Q2 power supply current : 1132.11
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.41
    Right Arm Q2 momentum : 2.63057
    Hall A momentum orbit correction (dpp) : -8.76388e-06
    Right Arm Q2 gauss meter : 0.5925
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6067.41
     enabled
    Right Arm D1 power supply current : 932.841
    Hall C energy (hallc_MeV) : 6070.48
    Right Arm D1 momentum : 2.62998
    Right Arm D1 NMR : 0.975955
    Right Arm arm angle : 20.001
    Right Arm Q3 power supply current : 1046.64
    Right Arm Q3 momentum : 2.63035
    Delta(E)/E width (MV_AI_DXWID) : 0.0548458
    Right Arm Q3 gauss meter : 0.4684
    IPM1C12.XPOS : -0.00255504
    Right Arm Q3 power supply polarity : disabled
    IPM1H04A.XPOS : -2.96748
    -----
    Average current of the two cavities : 5.14921
    IPM1H04A.YPOS : 1.36869
    Current on Unser monitor : 22.4151
    IPM1H04B.YPOS : 1.62561
    -----
    Wien angle : 74.7279
    Current on Upstream bcm : 5.01422
    Wien BDL : 1724.8
    Current on Downstream bcm : 5.2842
    Wien field : 49.796
    Laser attenuation Hall A : 65
    Upstream Cavity Coefficient : 42.6
    Laser power Hall A : 100
    Downstream Cavity Coefficient : 43.8
    Half-wave plate (off=out) : OUT
    Current on IBC0L02 (source) : 5.33673
    rotating waveplate : 1200
    Hall C Current : 0
    MBSY1c magnet current (amp) : 254.343
    -----
    Helicity Settle Read : 500
    MBSY1c Bdl : 1.51764e+06
    Helicity Delay Read : 8 cycles
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.39
    Helicity Pattern : Quartet
    -----
    Hall A momentum orbit correction (dpp) : -1.19221e-05
    Target : Carbon Hole
    Hall A setup momentum (MMSHLAE) : 6067.5
    fan frequency loop 1 : 59.5
    Hall A energy (halla_MeV) : 6067.39
    Hall C energy (hallc_MeV) : 6070.48
    fan frequency loop 3 : 0
    Encoder position : 9.05468e+06
    Target type : 9.05468e+06
    temperature loop 1(1) : 21.99
    Delta(E)/E width (MV_AI_DXWID) : 0.0548683
    temperature loop 1(2) : 21.94
    temperature loop 1(3) : 22.27
    IPM1C12.XPOS : -0.00921869
    temperature loop 3(1) : 99.99
    IPM1H04A.XPOS : -2.9697
    temperature loop 3(2) : 99.99
    IPM1H04A.YPOS : 1.3796
    temperature loop 3(3) : 29.99
    IPM1H04B.XPOS : -3.14775
    Heat exchange LH2 : 274.8
    IPM1H04B.YPOS : 1.63764
    -----
    HPH H2 loop 1 : 1043.88
    Wien angle : 74.7279
    HPH H2 loop 3 : 0.0244217
    Wien BDL : 1724.8