     Run Number: 4817
     End of Run Comment:
    Run_type=Check out,target_type=Holey C12,targetpol_poldir=Longitudinal,targetpol_pol=87,beam_e0=6.0,beam_raster=off,beam_current=0.0,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=19.0,rightarm_sieve=out,comment_text=@Both bpm X =- 3.0mm
     
    
    PRESCALE FACTORS:ps1=1   ps2=16777215   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 42317        
    TIME     : [0]: 4.313 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  52.21%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :342.1/342.1 Hz   T2[0] : 0.0/17.6 Hz   T3[0] : 0.0/23.5 Hz   T4[0] : 0.0/19.7 Hz   T5[0] : 0.0/27.2 Hz   T6[0] : 0.0/13.0 Hz   T7[0] : 0.1/6694.4 Hz   T8[0] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  88522/88522    T2[0] :      0/4562     T3[0] :      0/6083     T4[0] :      0/5087     T5[0] :      0/7034     T6[0] :      0/3370     T7[0] :     26/1732484  T8[0] :      4/265009   
    
    AVERAGE CURRENT
    BCM x1 : 2.3833 uA  BCM x3 : 0.4264 uA  BCM x10: 2.4782 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:-3.954E-05     BCM u3 [0]:0.0002251      BCM u10[0]:-4.915E-06     
    
    BCM d1 [0]:0.001273       BCM d3 [0]:-4.362E-06     BCM d10[0]:0.001288       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4817 at Fri Nov 6 22:29:20 EST 2009
    
    Left Arm Top VDC Current : 5.32227
    Right Arm Bottom VDC voltage : 3.99658
    -----
    Left Arm Bottom VDC Current : 1.5625
    Left Arm Top VDC voltage : 4.00195
    Left Arm Bottom VDC voltage : 4.00049
    -----
    Left Arm Q1 momentum : 3.66043
    Right Arm Top VDC Current : -13.1348
    Left Arm Q1 power supply : 2753.8
    Right Arm Bottom VDC Current : -0.683594
    Left Arm Q1 gauss meter : -0.23218
    Right Arm Top VDC voltage : 4.00537
    Left Arm Q2 gauss meter : 0.8273
    Right Arm Bottom VDC voltage : 3.99658
    -----
    Left Arm Q2 power supply current : 1575.84
    Left Arm Q1 momentum : 3.66043
    Left Arm Q2 momentum : 3.65963
    Left Arm Q1 power supply : 2753.8
    Left Arm Q2 power supply polarity : disabled
    Left Arm Q1 gauss meter : -0.23218
    Left Arm D1 power supply current : 1325.23
    Left Arm Q2 gauss meter : 0.8273
    Left Arm D1 momentum : 3.66009
    Left Arm Q2 power supply current : 1575.84
    Left Arm D1 NMR : 1.35577
    Left Arm Q2 momentum : 3.65963
    Left Arm arm angle : 12.8988
    Left Arm Q2 power supply polarity : disabled
    Left Arm Q3 gauss meter : -0.73459
    Left Arm D1 power supply current : 1325.23
    Left Arm D1 momentum : 3.66009
    Left Arm Q3 power supply current : 1457.2
    Left Arm D1 NMR : 1.35577
    Left Arm Q3 momentum : 3.66022
    Left Arm arm angle : 12.8988
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 2.62972
    Left Arm Q3 gauss meter : -0.73459
    Right Arm Q1 power supply : 1977.38
    Left Arm Q3 power supply current : 1457.2
    Right Arm Q1 gauss meter : -0.04911
    Left Arm Q3 momentum : 3.66022
    Right Arm Q2 power supply current : 1132.11
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q2 momentum : 2.63057
    Right Arm Q1 momentum : 2.62972
    Right Arm Q1 power supply : 1977.38
    Right Arm Q2 gauss meter : 0.5924
    Right Arm Q1 gauss meter : -0.04911
    Right Arm Q2 power supply polarity : enabled
    Right Arm Q2 power supply current : 1132.11
    Right Arm Q2 momentum : 2.63057
    Right Arm D1 power supply current : 932.84
    Right Arm Q2 gauss meter : 0.5925
    Right Arm D1 momentum : 2.62999
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 NMR : 0.975958
    Right Arm D1 power supply current : 932.84
    Right Arm arm angle : 20.001
    Right Arm D1 momentum : 2.62999
    Right Arm Q3 power supply current : 1046.64
    Right Arm D1 NMR : 0.975958
    Right Arm Q3 momentum : 2.63035
    Right Arm arm angle : 20.001
    Right Arm Q3 gauss meter : 0.4683
    Right Arm Q3 power supply current : 1046.64
    Right Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q3 momentum : 2.63035
    Average current of the two cavities : 2.78503
    Right Arm Q3 gauss meter : 0.4683
    Right Arm Q3 power supply polarity : disabled
    -----
    Current on Unser monitor : 22.7994
     : 2.78503
    Current on Upstream bcm : 2.15663
    Current on Unser monitor : 22.7994
    Current on Downstream bcm : 3.41343
    Current on Upstream bcm : 2.15663
    Upstream Cavity Coefficient : 42.6
    Current on Downstream bcm : 3.41343
    Downstream Cavity Coefficient : 43.8
    Upstream Cavity Coefficient : 42.6
    Current on IBC0L02 (source) : 3.37191
    Downstream Cavity Coefficient : 43.8
    Hall C Current : 0
    Current on IBC0L02 (source) : 3.37191
    MBSY1c magnet current (amp) : 254.343
    Hall C Current : 0
    MBSY1c Bdl : 1.51764e+06
    MBSY1c magnet current (amp) : 254.343
    Hall A momentum (Tiefenbach) (HALLA:p) : 6066.41
    MBSY1c Bdl : 1.51764e+06
    Hall A momentum orbit correction (dpp) : -0.000172508
    Hall A momentum (Tiefenbach) (HALLA:p) : 6066.41
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6066.41
    Hall A momentum orbit correction (dpp) : -0.000172508
    Hall C energy (hallc_MeV) : 6070.48
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6066.41
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 0.0548667
    Delta(E)/E width (MV_AI_DXWID) : 0.0548667
    IPM1C12.XPOS : -0.118458
    IPM1C12.XPOS : -0.118458
    IPM1H04A.XPOS : -2.96568
    IPM1H04A.XPOS : -2.96568
    IPM1H04A.YPOS : 0.872196
    IPM1H04A.YPOS : 0.872196
    IPM1H04B.XPOS : -3.14151
    IPM1H04B.XPOS : -3.14151
    IPM1H04B.YPOS : 0.909279
    -----
    IPM1H04B.YPOS : 0.909279
    -----
    Wien angle : 74.7279
    Wien BDL : 1724.8
    Wien angle : 74.7279
    Wien field : 49.796
    Wien BDL : 1724.8
    Laser attenuation Hall A : 68
    Wien field : 49.796
    Laser power Hall A : 100
    Laser attenuation Hall A : 68
    Half-wave plate (off=out) : OUT
    Laser power Hall A : 100
    
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    -----
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Settle Read : 500
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    -----
    Helicity Pattern : Quartet
    -----
    Target : Carbon Hole
    Target : Carbon Hole
    fan frequency loop 1 : 59.5
    fan frequency loop 1 : 59.5
    fan frequency loop 3 : 0
    fan frequency loop 3 : 0
    Encoder position : 9.05468e+06
    Encoder position : 9.05468e+06
    Target type : 9.05468e+06
    Target type : 9.05468e+06
    temperature loop 1(1) : 21.98
    temperature loop 1(1) : 21.98
    temperature loop 1(2) : 21.94
    temperature loop 1(2) : 21.94
    temperature loop 1(3) : 22.26
    temperature loop 1(3) : 22.26
    temperature loop 3(1) : 99.99
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.5
    Heat exchange LH2 : 24.5
    Heat exchange LH2 : 274.8
    Heat exchange LH2 : 274.8
    HPH H2 loop 1 : 1083.48
    HPH H2 loop 1 : 1083.48
    HPH H2 loop 3 : 0.00981605
    HPH H2 loop 3 : 0.00981605