Privacy and Security Notice

End_of_Run_4818


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 22:35:02 on November 6, 2009

    Entry number 297907

    keyword=End_of_Run_4818
    ****************************
     Run Number: 4818
     End of Run Comment:
    Run_type=Check out,target_type=Holey C12,targetpol_poldir=Longitudinal,targetpol_pol=87,beam_e0=6.0,beam_raster=off,beam_current=0.0,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=19.0,rightarm_sieve=out,comment_text=@Both BPM A =B = (-3.0, 1.5)mm
     
    
    PRESCALE FACTORS:ps1=1   ps2=16777215   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 40813        
    TIME     : [0]: 4.977 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  52.07%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :285.0/285.0 Hz   T2[0] : 0.0/15.6 Hz   T3[0] : 0.0/19.7 Hz   T4[0] : 0.0/16.2 Hz   T5[0] : 0.0/22.3 Hz   T6[0] : 0.0/11.1 Hz   T7[0] : 0.1/6536.6 Hz   T8[0] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  85118/85118    T2[0] :      0/4653     T3[0] :      0/5897     T4[0] :      0/4849     T5[0] :      0/6667     T6[0] :      0/3304     T7[0] :     29/1952059  T8[0] :      4/305803   
    
    AVERAGE CURRENT
    BCM x1 : 1.9475 uA  BCM x3 : 0.4156 uA  BCM x10: 2.0378 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:-4.563E-05     BCM u3 [0]:0.0002533      BCM u10[0]:-5.723E-06     
    
    BCM d1 [0]:0.001209       BCM d3 [0]:-5.033E-06     BCM d10[0]:0.001223       
    
    
    
    ****************************
    Left Arm Q1 gauss meter : -0.23218
    End-of-run EPICS data for Run Number 4818 at Fri Nov 6 22:34:58 EST 2009
    
    Left Arm Q2 gauss meter : 0.8273
    Left Arm Top VDC Current : 5.46875
    1575.84
    Left Arm Q2 momentum : 3.65963
    Left Arm Bottom VDC Current : 4.83398
    Left Arm Q2 power supply polarity : disabled
    Left Arm Top VDC voltage : 4
    Left Arm D1 power supply current : 1325.22
    Left Arm D1 momentum : 3.66009
    Left Arm Bottom VDC voltage : 4.00049
    -----
    Left Arm D1 NMR : 1.35577
    Right Arm Top VDC Current : -24.5605
    Left Arm arm angle : 12.8988
    Right Arm Bottom VDC Current : 0.732422
    Left Arm Q3 gauss meter : -0.73458
    Right Arm Top VDC voltage : 4.00488
    Left Arm Q3 power supply current : 1457.2
    Right Arm Bottom VDC voltage : 4.00488
    -----
    Left Arm Q3 momentum : 3.66022
    Left Arm Q1 momentum : 3.66043
    Left Arm Q3 power supply polarity : disabled
    -----
    Left Arm Q1 power supply : 2753.86
    Right Arm Q1 momentum : 2.62972
    Left Arm Q1 gauss meter : -0.23218
    Right Arm Q1 power supply : 1977.38
    Left Arm Q2 gauss meter : 0.8273
    Right Arm Q1 gauss meter : -0.04912
    Left Arm Q2 power supply current : 1575.84
    Right Arm Q2 power supply current : 1132.11
    Left Arm Q2 momentum : 3.65963
    Right Arm Q2 momentum : 2.63057
    Left Arm Q2 power supply polarity : disabled
    Right Arm Q2 gauss meter : 0.5925
    Left Arm D1 power supply current : 1325.23
    Left Arm D1 momentum : 3.66009
    Right Arm Q2 power supply polarity : enabled
    Left Arm D1 NMR : 1.35577
    Right Arm D1 power supply current : 932.84
    Left Arm arm angle : 12.8988
    Right Arm D1 momentum : 2.62999
    Left Arm Q3 gauss meter : -0.73459
    Right Arm D1 NMR : 0.975958
    Left Arm Q3 power supply current : 1457.2
    Right Arm arm angle : 20.001
    Left Arm Q3 momentum : 3.66022
    Right Arm Q3 power supply current : 1046.64
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q3 momentum : 2.63036
    Right Arm Q1 momentum : 2.62972
    Right Arm Q3 gauss meter : 0.4684
    Right Arm Q1 power supply : 1977.38
    Right Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 gauss meter : -0.04912
    Average current of the two cavities : 5.09834
    Right Arm Q2 power supply current : 1132.11
    Current on Unser monitor : 21.9183
    Current on Upstream bcm : 4.95893
    Right Arm Q2 momentum : 2.63057
    Current on Downstream bcm : 5.23775
    Right Arm Q2 gauss meter : 0.5925
    Upstream Cavity Coefficient : 42.6
    Right Arm Q2 power supply polarity : enabled
    Downstream Cavity Coefficient : 43.8
    Right Arm D1 power supply current : 932.841
    Current on IBC0L02 (source) : 5.22667
    Right Arm D1 momentum : 2.62999
    Hall C Current : 0
    Right Arm D1 NMR : 0.975958
    MBSY1c magnet current (amp) : 254.343
    Right Arm arm angle : 20.001
    MBSY1c Bdl : 1.51764e+06
    Right Arm Q3 power supply current : 1046.64
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.35
    Right Arm Q3 momentum : 2.63036
    Hall A momentum orbit correction (dpp) : -1.71651e-05
    Hall A setup momentum (MMSHLAE) : 6067.5
    Right Arm Q3 gauss meter : 0.4684
    Right Arm Q3 power supply polarity : disabled
    -----
    Hall A energy (halla_MeV) : 6067.35
    Hall C energy (hallc_MeV) : 6070.48
    Average current of the two cavities : 5.09
    Delta(E)/E width (MV_AI_DXWID) : 0.0548468
    Current on Unser monitor : 22.3301
    IPM1C12.XPOS : -0.0030905
    Current on Upstream bcm : 4.95893
    IPM1H04A.XPOS : -2.91746
    Current on Downstream bcm : 5.22106
    IPM1H04A.YPOS : 1.74896
    IPM1H04B.XPOS : -3.04514
    Upstream Cavity Coefficient : 42.6
    IPM1H04B.YPOS : 1.85474
    -----
    Downstream Cavity Coefficient : 43.8
    Wien angle : 74.7279
    Current on IBC0L02 (source) : 5.22667
    Wien BDL : 1724.8
    Hall C Current : 0
    Wien field : 49.796
    Laser attenuation Hall A : 65
    MBSY1c magnet current (amp) : 254.343
    Laser power Hall A : 100
    MBSY1c Bdl : 1.51764e+06
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    -----
    Target : Carbon Hole
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.35
    fan frequency loop 1 : 59.5
    Hall A momentum orbit correction (dpp) : -1.71651e-05
    fan frequency loop 3 : 0
    Hall A setup momentum (MMSHLAE) : 6067.5
    Encoder position : 9.05468e+06
    Hall A energy (halla_MeV) : 6067.35
    Target type : 9.05468e+06
    Hall C energy (hallc_MeV) : 6070.48
    temperature loop 1(1) : 22.01
    Delta(E)/E width (MV_AI_DXWID) : 0.0548446
    temperature loop 1(2) : 21.97
    IPM1C12.XPOS : -0.0116682
    temperature loop 1(3) : 22.29
    IPM1H04A.XPOS : -2.92859
    temperature loop 3(1) : 99.99
    IPM1H04A.YPOS : 1.72646
    temperature loop 3(2) : 99.99
    IPM1H04B.XPOS : -3.05858
    temperature loop 3(3) : 29.99
    IPM1H04B.YPOS : 1.83999
    -----
    Heat exchange LH2 : 24.5
    Wien angle : 74.7279
    Heat exchange LH2 : 274.9
    Wien BDL : 1724.8
    HPH H2 loop 1 : 1043.88
    Wien field : 49.796
    HPH H2 loop 3 : 0.011068