     Run Number: 4828
     End of Run Comment:
    Run_type=Check out,target_type=LD2, 20cm,targetpol_poldir=Longitudinal,targetpol_pol=87,beam_e0=6.0,beam_raster=on,beam_current=2.0,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=19.0,rightarm_sieve=out,comment_text=spot++
     
    
    PRESCALE FACTORS:ps1=10   ps2=16777215   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 168377       
    TIME     : [0]: 1.175 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  64.39%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :6707.0/67070.3 Hz   T2[0] : 0.0/1805.2 Hz   T3[0] : 0.0/3112.5 Hz   T4[0] : 0.0/3536.8 Hz   T5[0] : 0.1/6507.6 Hz   T6[0] : 0.0/1758.1 Hz   T7[0] : 1.1/71657.1 Hz   T8[0] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 472767/4727672  T2[0] :      0/127248   T3[0] :      0/219397   T4[0] :      0/249301   T5[0] :      6/458709   T6[0] :      1/123927   T7[0] :     77/5050985  T8[0] :      1/72180    
    
    AVERAGE CURRENT
    BCM x1 : 19.0327uA  BCM x3 : 4.8793 uA  BCM x10: 16.5593uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:-1.077E-05     BCM u3 [0]:0.0006891      BCM u10[0]:8.528E-06      
    
    BCM d1 [0]:0.002694       BCM d3 [0]:-1.188E-06     BCM d10[0]:0.002326       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4828 at Sat Nov 7 03:31:33 EST 2009
    
    Left Arm Top VDC Current : 1.46484
    Left Arm Bottom VDC Current : 1.46484
    Left Arm Top VDC voltage : 0.0170898
    Left Arm Bottom VDC voltage : 0.0185547
    -----
    Right Arm Top VDC Current : -1.80664
    Right Arm Bottom VDC Current : -1.41602
    Right Arm Top VDC voltage : -0.00488281
    Right Arm Bottom VDC voltage : -0.0107422
    -----
    Left Arm Q1 momentum : 3.66029
    Left Arm Q1 power supply : 2753.75
    Left Arm Q1 gauss meter : -0.23217
    Left Arm Q2 gauss meter : 0.8273
    Left Arm Q2 power supply current : 1575.84
    Left Arm Q2 momentum : 3.65964
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.22
    Left Arm D1 momentum : 3.66007
    Left Arm D1 NMR : 1.35577
    Left Arm arm angle : 12.8988
    Left Arm Q3 gauss meter : -0.73461
    Left Arm Q3 power supply current : 1457.21
    Left Arm Q3 momentum : 3.66023
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 2.62958
    Right Arm Q1 power supply : 1977.27
    Right Arm Q1 gauss meter : -0.04911
    Right Arm Q2 power supply current : 1132.11
    Right Arm Q2 momentum : 2.63057
    Right Arm Q2 gauss meter : 0.5925
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 932.84
    Right Arm D1 momentum : 2.62999
    Right Arm D1 NMR : 0.975958
    Right Arm arm angle : 20.001
    Right Arm Q3 power supply current : 1046.63
    Right Arm Q3 momentum : 2.63034
    Right Arm Q3 gauss meter : 0.4683
    Right Arm Q3 power supply polarity : disabled
    -----
    Average current of the two cavities : 75.5343
    Current on Unser monitor : 91.1964
    Current on Upstream bcm : 74.7634
    Current on Downstream bcm : 76.3052
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 75.0013
    Hall C Current : 0
    MBSY1c magnet current (amp) : 254.343
    MBSY1c Bdl : 1.51764e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.37
    Hall A momentum orbit correction (dpp) : -1.4457e-05
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6067.37
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 0.0549
    IPM1C12.XPOS : 0.00953281
    IPM1H04A.XPOS : -2.85297
    IPM1H04A.YPOS : 1.92404
    IPM1H04B.XPOS : -2.9802
    IPM1H04B.YPOS : 1.96863
    -----
    Wien angle : 74.7279
    Wien BDL : 1724.8
    Wien field : 49.796
    Laser attenuation Hall A : 111
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    -----
    Target : L1 20cm
    fan frequency loop 1 : 60
    fan frequency loop 3 : 0
    Encoder position : 3.30777e+07
    Target type : 3.30777e+07
    temperature loop 1(1) : 22
    temperature loop 1(2) : 21.96
    temperature loop 1(3) : 22.46
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.7
    Heat exchange LH2 : 274
    HPH H2 loop 1 : 457.224
    HPH H2 loop 3 : 0.00634721