Privacy and Security Notice

End_of_Parity_Run_13779__CODA_Config=Pvdis


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name apar

    Log entry time 04:24:22 on November 7, 2009

    Entry number 298003

    keyword=End_of_Parity_Run_13779__CODA_Config=Pvdis
    ************************************************
     Run Number: 13779
     End of Run Comment:
    
    Run_type=Test,beam_energy=3.4839,beam_polarization=87,beam_raster=on,comment_text=boiling test, Lumi HV adjust, @20uA, LD2 target, fan speed 39Hz, raster size 6x6 (mcc unit),dithering_magnet=off,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=off,parity_ihwp=out,rightarm_p=pi,rightarm_theta=14,target_fanspeed=60,target_type=20cm LD2
    ************************************************
    End-of-Parity-run EPICS data for Run Number 13779 at Sat Nov  7 04:24:12 EST 2009
    CODA Configuration: Pvdis
    
    
    
    Compton Run Number                       : 20887
    -----------------------------------------
    Wien angle                               : 74.7279
    Wien BDL                                 : 1724.8
    Wien field                               : 49.796
    Laser attenuation Hall A                 : 82
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : OUT
    Beam Half-wave plate Read(off=out)       : OUT
    Rotating waveplate                       : 1200
    IA Cell Setpoint  Hall A                 : 4.79
    IA Cell Setpoint  Hall C                 : 4.3
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 4.5
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 7.681
    Gun2: PC (PITA) NEG                      : 7.019
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 1.99267
    Pockels Cell Voltage NEG                 : 1.84371
    Helicity Clock Set                       : Free Clock
    Helicity Delay Set                       : 8 cycles
    Helicity Pattern Set                     : Quartet
    Helicity Clock Read                      : Free Clock
    Helicity Settle Read                     : 500
    Helicity Delay Read                      : 8 cycles
    Helicity Pattern Read                    : Quartet
    Helicity Frequency                       : 29.5596
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : Pwr741mW
    Calculated power in cavity               : 0.231206
    Photodiode on table                      : 381.107
    Laser X position on QPD 1                : 120.486
    Laser Y position on QPD 1                : 517.127
    Laser X position on QPD 2                : 17.7625
    Laser Y position on QPD 2                : -604.842
    QPD 1 sum                                : -1.54184
    QPD 2 sum                                : -1.17561
    Position set point for adjustable 
                   mirror 1 (either x or y)  : -1520[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : -1420[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : +47.2709
    Polarisation in cavity                   : LEFT
    Reflection photodiode                    : 0.841726
    Gain of locking servo                    : 135
    Tracking level (V) of locking servo      : 0.65
    Slow locking signal sent to laser        : 0.148324
    Fast locking signal sent to laser        : 8.63761
    Calculated polarisation in cavity        : 20.9624
    Photodiode 1 after Wollaston prism       : 0.0112718
    Photodiode 2 after Wollaston prism       : 0.00736503
    Step size for RHWP scan                  : 0
    Laser temp slow ramp (1 = on)            : ON
    Extent of laser temp slow ramp (C)       : 0.05
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Left Arm Magnets
    -----------------------------------------
    Left Arm Q1 power supply current         : 2753.8
    Left Arm Q1 momentum                     : 3.66036
    Left Arm Q1 gauss meter                  : -0.23214
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 1575.83
    Left Arm Q2 momentum                     : 3.65961
    Left Arm Q2 gauss meter                  : 0.8272
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : 1325.23
    Left Arm D1 momentum                     : 3.66008
    Left Arm D1 NMR                          : 1.35577
    Left Arm Q3 power supply current         : 1457.2
    Left Arm Q3 momentum                     : 3.66022
    Left Arm Q3 gauss meter                  : -0.73458
    Left Arm Q3 power supply polarity        : disabled
    -----------------------------------------
    Right Arm Magnets
    -----------------------------------------
    Right Arm Q1 power supply current        : 1977.33
    Right Arm Q1 momentum                    : 2.62965
    Right Arm Q1 gauss meter                 : -0.04911
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 1132.11
    Right Arm Q2 momentum                    : 2.63056
    Right Arm Q2 gauss meter                 : 0.5924
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 932.839
    Right Arm D1 momentum                    : 2.62999
    Right Arm D1 NMR                         : 0.975958
    Right Arm Q3 power supply current        : 1046.63
    Right Arm Q3 momentum                    : 2.63034
    Right Arm Q3 gauss meter                 : 0.4684
    Right Arm Q3 power supply polarity       : disabled
    -----------------------------------------
    HallA & Injector BCMs and Energy
    -----------------------------------------
    Average current of the two cavities      : 20.286
    Current on Unser monitor                 : 37.4885
    Current on Upstream bcm                  : 19.7505
    Current on Downstream bcm                : 20.8214
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 20.3713
    Tiefenbach Hall A energy                 : 6067.4
    Tiefenbach Hall C energy                 : 6070.48
    Delta(E)/E width (MV_AI_DXWID)           : 0.0548549
    MBSY1c Hall A Beam energy                : 6081.48
    MBSY3c Hall C Beam energy                : 6090.49
    MBSY1c magnet current (amp)              : 254.343
    MBSY1c Bdl                               : 1.51764e+06
    -----------------------------------------
    ARC stuff and Raster
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Raster X width                                : 6
    Raster Y width                                : 6
    -----------------------------------------
    Target BPMs
    -----------------------------------------
    IPM1C12.XPOS                             : -0.00249863
    IPM1C12.YPOS                             : 0.173723
    IPM1H04A.XPOS                            : -2.9034
    IPM1H04A.YPOS                            : 1.93829
    IPM1H04B.XPOS                            : -3.00365
    IPM1H04B.YPOS                            : 1.99299
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : -0.0028877
    Survey Y offset bpm12                     : 0.185927
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    Target                                   : L1 20cm
    Encoder position                         : 33077688
    fan frequency loop 1                     : 38.5
    fan frequency loop 2                     : 0
    fan frequency loop 3                     : 0
    temperature loop 1-1                     : 22.01
    temperature loop 1-2                     : 21.97
    temperature loop 1-3                     : 22.38
    temperature loop 2-1                     : 100.09
    temperature loop 2-2                     : 95.14
    temperature loop 2-3                     : 119.99
    temperature loop 3-1                     : 99.99
    temperature loop 3-2                     : 99.99
    temperature loop 3-3                     : 29.99
    pressure fill target H2                  : 25.5329
    pressure fill bottle H2                  : 25.5924
    pressure ballast H2                      : 25.832
    pressure exhaust H2                      : 25.9632
    cryogen input temp                       : 219.2
    crogen return flow                       : 0.369902
     JT valve setting                        : -0.390625
    -----------------------------------------
    Parameters used for HAPPEX feedback
    -----------------------------------------
    Parity DAQ Feedback Control (ON=1)        : 0
    No HAPPEX feedback runlog entry for Run #13779
      Was feedback on?