Privacy and Security Notice

End_of_Run_25300


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 07:05:38 on November 7, 2009

    Entry number 298037

    keyword=End_of_Run_25300
    ****************************
     Run Number: 25300
     End of Run Comment:
    Run_type=Check out,target_type=LD2, 20cm,targetpol_poldir=Longitudinal,targetpol_pol=87,beam_e0=6.0,beam_raster=on,beam_current=2.0,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=19.0,rightarm_sieve=out,comment_text=checking timing for PVDIS
     
    
    PRESCALE FACTORS:ps1=1   ps2=99999   ps3=99999   ps4=99999   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 1018362      
    TIME     : [0]: 3.367 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  86.64%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :37728.4/37728.4 Hz   T2[0] : 0.0/398.0 Hz   T3[0] : 0.1/7922.8 Hz   T4[0] : 0.1/7601.7 Hz   T5[0] : 0.1/9209.5 Hz   T6[0] : 0.0/119.9 Hz   T7[0] : 0.6/41785.3 Hz   T8[0] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :7622937/7622937  T2[0] :      0/80407    T3[0] :     16/1600783  T4[0] :     15/1535907  T5[0] :     28/1860756  T6[0] :      0/24234    T7[0] :    128/8442634  T8[0] :      3/206897   
    
    AVERAGE CURRENT
    BCM x1 : 9.4610 uA  BCM x3 : 2.5536 uA  BCM x10: 9.5550 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.001904       BCM u3 [0]:0.001035       BCM u10[0]:0.001921       
    
    BCM d1 [0]:0.00192        BCM d3 [0]:-3.405E-06     BCM d10[0]:0.00194        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 25300 at Sat Nov 7 07:05:33 EST 2009
    
    Left Arm Top VDC Current : 1.46484
    Left Arm Bottom VDC Current : 1.51367
    Left Arm Top VDC voltage : 0.0185547
    Left Arm Bottom VDC voltage : 0.0180664
    -----
    Right Arm Top VDC Current : -1.80664
    Right Arm Bottom VDC Current : -1.41602
    Right Arm Top VDC voltage : -0.00537109
    Right Arm Bottom VDC voltage : -0.0112305
    -----
    Left Arm Q1 momentum : 3.66036
    Left Arm Q1 power supply : 2753.86
    Left Arm Q1 gauss meter : -0.23214
    Left Arm Q2 gauss meter : 0.8272
    Left Arm Q2 power supply current : 1575.84
    Left Arm Q2 momentum : 3.65964
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.23
    Left Arm D1 momentum : 3.66008
    Left Arm D1 NMR : 1.35577
    Left Arm arm angle : 12.8988
    Left Arm Q3 gauss meter : -0.73459
    Left Arm Q3 power supply current : 1457.2
    Left Arm Q3 momentum : 3.66021
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 2.62972
    Right Arm Q1 power supply : 1977.38
    Right Arm Q1 gauss meter : -0.04912
    Right Arm Q2 power supply current : 1132.1
    Right Arm Q2 momentum : 2.63055
    Right Arm Q2 gauss meter : 0.5925
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 932.838
    Right Arm D1 momentum : 2.62999
    Right Arm D1 NMR : 0.975958
    Right Arm arm angle : 20.001
    Right Arm Q3 power supply current : 1046.63
    Right Arm Q3 momentum : 2.63033
    Right Arm Q3 gauss meter : 0.4684
    Right Arm Q3 power supply polarity : disabled
    -----
    Average current of the two cavities : 9.676
    Current on Unser monitor : 26.3614
    Current on Upstream bcm : 9.4229
    Current on Downstream bcm : 9.92911
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 9.85997
    Hall C Current : 0
    MBSY1c magnet current (amp) : 254.343
    MBSY1c Bdl : 1.51764e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.4
    Hall A momentum orbit correction (dpp) : -9.87797e-06
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6067.4
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 0.761379
    IPM1C12.XPOS : 0.00306562
    IPM1H04A.XPOS : -2.90801
    IPM1H04A.YPOS : 1.92583
    IPM1H04B.XPOS : -2.9945
    IPM1H04B.YPOS : 1.97094
    -----
    Wien angle : 74.7279
    Wien BDL : 1724.8
    Wien field : 49.796
    Laser attenuation Hall A : 73
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    -----
    Target : L1 20cm
    fan frequency loop 1 : 50.5
    fan frequency loop 3 : 0
    Encoder position : 3.30777e+07
    Target type : 3.30777e+07
    temperature loop 1(1) : 21.99
    temperature loop 1(2) : 21.95
    temperature loop 1(3) : 22.29
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.5
    Heat exchange LH2 : 273.4
    HPH H2 loop 1 : 1055.85
    HPH H2 loop 3 : 0.000817917