Privacy and Security Notice

boiling test, fan speed part


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name deng/dwang

    Log entry time 07:27:25 on November 7,2009

    Entry number 298044

    This entry is a followup to: 297771

    keyword=boiling test, fan speed part

    Since MCC has trouble sending us beam higher than 85uA, we did fan speed at 40, 
    50, 60Hz at beam currents 10, 20 and 85uA with raster size 6x6 in MCC unit.
    
    Before we did fan speed test, three runs were taken at 85uA with fan speed at 
    60Hz and raster size 2x2, 4x4 and 6x6 (all mcc unit) to repeat raster size test 
    done yesterday owl shift. This is because when we did raster size test 
    yesterday, the right arm Q1 was down while the one in left arm was fine. Rupesh 
    mentioned that the lumi width would be quite different in this situation 
    compared to both arm Q1 on or off. This is verified by the test.
    
    1) raster size test results @85uA
    
     run  target raster size  good pairs   AsymNBlumiSum width (ppm)
    
     13774 LD2     6x6          9.8K         557.9
    
     13775 LD2     2x2         10.8K          6635
    
     13776 LD2     4x4          5.8K          1650  
    
    while yesterday,
    
     13752 LD2     6x6          6.2K         592.3
    
     13753 LD2     4x4          8.7K          1874
    
     13754 LD2     2x2         13.7K          7361
    
    2) fan speed test, raster size 6x6 in MCC unit
    
      run || target || current || fan speed || #pairs || AsymNBlumiSum width
    
      13774   LD2         85uA      60Hz         9.8K         557.9
    
      13777   LD2         85uA      50Hz         6.7K         840
    
      13778   LD2         85uA      40Hz         7.8K         2088
    
      13780   LD2         20uA      40Hz         6.7K         293.3
      
      13781   LD2         20uA      50Hz         6.6K         280.6
    
      13782   LD2         20uA      60Hz         7.1K          274
    
      13784   LD2         10uA      60Hz         6.9K         448.9
    
      13787   LD2         10uA      50Hz         9.3K         459.8
    
      13788   LD2         10uA      40Hz         8.1K         471.6