     Run Number: 25301
     End of Run Comment:
    Run_type=Check out,target_type=LD2, 20cm,targetpol_poldir=Longitudinal,targetpol_pol=87,beam_e0=6.0,beam_raster=on,beam_current=2.0,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=19.0,rightarm_sieve=out,comment_text=checking timing for PVDIS
     
    
    PRESCALE FACTORS:ps1=40   ps2=99999   ps3=99999   ps4=99999   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 1005619      
    TIME     : [0]: 17.692 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:   0.70%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :953.1/38122.6 Hz   T2[0] : 0.0/407.3 Hz   T3[0] : 0.1/8006.9 Hz   T4[0] : 0.1/7685.2 Hz   T5[0] : 0.1/9211.4 Hz   T6[0] : 0.0/26.8 Hz   T7[0] : 0.6/42215.3 Hz   T8[0] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :1011685/40467438  T2[0] :      4/432369   T3[0] :     84/8499326  T4[0] :     81/8157866  T5[0] :    149/9777952  T6[0] :      0/28490    T7[0] :    683/44811812  T8[0] :     16/1086983  
    
    AVERAGE CURRENT
    BCM x1 : 9.5650 uA  BCM x3 : 2.5807 uA  BCM x10: 9.6600 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.01011        BCM u3 [0]:0.005497       BCM u10[0]:0.01021        
    
    BCM d1 [0]:0.01019        BCM d3 [0]:-1.789E-05     BCM d10[0]:0.0103         
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 25301 at Sat Nov 7 07:30:40 EST 2009
    
    Left Arm Top VDC Current : 1.41602
    Left Arm Bottom VDC Current : 1.41602
    Left Arm Top VDC voltage : 0.0180664
    Left Arm Bottom VDC voltage : 0.019043
    -----
    Right Arm Top VDC Current : -1.85547
    Right Arm Bottom VDC Current : -1.46484
    Right Arm Top VDC voltage : -0.00439453
    Right Arm Bottom VDC voltage : -0.0102539
    -----
    Left Arm Q1 momentum : 3.66036
    Left Arm Q1 power supply : 2753.86
    Left Arm Q1 gauss meter : -0.23215
    Left Arm Q2 gauss meter : 0.8273
    Left Arm Q2 power supply current : 1575.85
    Left Arm Q2 momentum : 3.65966
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.23
    Left Arm D1 momentum : 3.66008
    Left Arm D1 NMR : 1.35577
    Left Arm arm angle : 12.8988
    Left Arm Q3 gauss meter : -0.73457
    Left Arm Q3 power supply current : 1457.2
    Left Arm Q3 momentum : 3.66021
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 2.62972
    Right Arm Q1 power supply : 1977.38
    Right Arm Q1 gauss meter : -0.04909
    Right Arm Q2 power supply current : 1132.11
    Right Arm Q2 momentum : 2.63057
    Right Arm Q2 gauss meter : 0.5924
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 932.842
    Right Arm D1 momentum : 2.62997
    Right Arm D1 NMR : 0.97595
    Right Arm arm angle : 20.001
    Right Arm Q3 power supply current : 1046.63
    Right Arm Q3 momentum : 2.63033
    Right Arm Q3 gauss meter : 0.4684
    Right Arm Q3 power supply polarity : disabled
    -----
    Average current of the two cavities : 10.4149
    Current on Unser monitor : 28.1975
    Current on Upstream bcm : 10.1403
    Current on Downstream bcm : 10.6895
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 10.5956
    Hall C Current : 0
    MBSY1c magnet current (amp) : 254.343
    MBSY1c Bdl : 1.51764e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.39
    Hall A momentum orbit correction (dpp) : -1.07953e-05
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6067.39
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 0.761379
    IPM1C12.XPOS : -0.000443637
    IPM1H04A.XPOS : -2.91335
    IPM1H04A.YPOS : 1.93024
    IPM1H04B.XPOS : -3.00231
    IPM1H04B.YPOS : 1.97667
    -----
    Wien angle : 74.7279
    Wien BDL : 1724.8
    Wien field : 49.796
    Laser attenuation Hall A : 74
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    -----
    Target : L1 20cm
    fan frequency loop 1 : 41
    fan frequency loop 3 : 0
    Encoder position : 3.30777e+07
    Target type : 3.30777e+07
    temperature loop 1(1) : 22
    temperature loop 1(2) : 21.96
    temperature loop 1(3) : 22.32
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.6
    Heat exchange LH2 : 273.4
    HPH H2 loop 1 : 1102.67
    HPH H2 loop 3 : 0.000504939