Privacy and Security Notice

End_of_Run_4832


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 08:15:31 on November 7, 2009

    Entry number 298059

    keyword=End_of_Run_4832
    ****************************
     Run Number: 4832
     End of Run Comment:
    Run_type=Check out,target_type=Optics,targetpol_poldir=Longitudinal,targetpol_pol=87,beam_e0=6.0,beam_raster=on,beam_current=2.0,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=19.0,rightarm_sieve=out,comment_text=Optics run. raster on, both sieves out
     
    
    PRESCALE FACTORS:ps1=1   ps2=16777215   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=2   
    
    EVENTS   : [0]: 344407       
    TIME     : [0]: 9.643 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  21.68%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :247.9/247.9 Hz   T2[0] : 0.0/13.4 Hz   T3[0] : 0.0/15.2 Hz   T4[0] : 0.0/12.9 Hz   T5[0] : 0.0/41.3 Hz   T6[0] : 0.0/8.0  Hz   T7[0] : 0.1/9074.9 Hz   T8[0] :512.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 143451/143451   T2[0] :      0/7747     T3[0] :      0/8817     T4[0] :      0/7469     T5[0] :      0/23880    T6[0] :      0/4640     T7[0] :     80/5250805  T8[0] : 296247/592494   
    
    AVERAGE CURRENT
    BCM x1 : 1.4230 uA  BCM x3 : 0.5896 uA  BCM x10: 1.5061 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:-8.841E-05     BCM u3 [0]:0.0006921      BCM u10[0]:-1.121E-05     
    
    BCM d1 [0]:0.001735       BCM d3 [0]:-9.752E-06     BCM d10[0]:0.001754       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4832 at Sat Nov 7 08:15:28 EST 2009
    
    Left Arm Top VDC Current : 5.66406
    Left Arm Bottom VDC Current : 1.41602
    Left Arm Top VDC voltage : 3.99561
    Left Arm Bottom VDC voltage : 4
    -----
    Right Arm Top VDC Current : 25.0488
    Right Arm Bottom VDC Current : -2.63672
    Right Arm Top VDC voltage : 3.99512
    Right Arm Bottom VDC voltage : 3.99805
    -----
    Left Arm Q1 momentum : 3.66036
    Left Arm Q1 power supply : 2753.8
    Left Arm Q1 gauss meter : -0.23216
    Left Arm Q2 gauss meter : 0.8272
    Left Arm Q2 power supply current : 1575.84
    Left Arm Q2 momentum : 3.65964
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.22
    Left Arm D1 momentum : 3.66007
    Left Arm D1 NMR : 1.35577
    Left Arm arm angle : 12.8988
    Left Arm Q3 gauss meter : -0.7346
    Left Arm Q3 power supply current : 1457.2
    Left Arm Q3 momentum : 3.66021
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 2.62965
    Right Arm Q1 power supply : 1977.33
    Right Arm Q1 gauss meter : -0.04912
    Right Arm Q2 power supply current : 1132.11
    Right Arm Q2 momentum : 2.63056
    Right Arm Q2 gauss meter : 0.5925
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 932.839
    Right Arm D1 momentum : 2.62999
    Right Arm D1 NMR : 0.975957
    Right Arm arm angle : 20.001
    Right Arm Q3 power supply current : 1046.63
    Right Arm Q3 momentum : 2.63033
    Right Arm Q3 gauss meter : 0.4683
    Right Arm Q3 power supply polarity : disabled
    -----
    Average current of the two cavities : 3.14068
    Current on Unser monitor : 21.2156
    Current on Upstream bcm : 3.04979
    Current on Downstream bcm : 3.23157
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 3.33792
    Hall C Current : 0
    MBSY1c magnet current (amp) : 254.343
    MBSY1c Bdl : 1.51764e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.37
    Hall A momentum orbit correction (dpp) : -1.52169e-05
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6067.37
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 0.761379
    IPM1C12.XPOS : 0.00380701
    IPM1H04A.XPOS : -2.89722
    IPM1H04A.YPOS : 1.92206
    IPM1H04B.XPOS : -3.00633
    IPM1H04B.YPOS : 1.97813
    -----
    Wien angle : 74.7279
    Wien BDL : 1724.8
    Wien field : 49.796
    Laser attenuation Hall A : 64
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    -----
    Target : Optics
    fan frequency loop 1 : 59.5
    fan frequency loop 3 : 0
    Encoder position : 1.26745e+07
    Target type : 1.26745e+07
    temperature loop 1(1) : 22
    temperature loop 1(2) : 21.96
    temperature loop 1(3) : 22.28
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.5
    Heat exchange LH2 : 273.2
    HPH H2 loop 1 : 1047.3
    HPH H2 loop 3 : 0.011068