Privacy and Security Notice

End_of_Run_4833


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 08:57:24 on November 7, 2009

    Entry number 298066

    keyword=End_of_Run_4833
    ****************************
     Run Number: 4833
     End of Run Comment:
    Run_type=Check out,target_type=Optics,targetpol_poldir=Longitudinal,targetpol_pol=87,beam_e0=6.0,beam_raster=on,beam_current=5.0,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=19.0,rightarm_sieve=out,comment_text=Optics run. raster off, both sieves out
     
    
    PRESCALE FACTORS:ps1=1   ps2=16777215   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 252682       
    TIME     : [0]: 32.436 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  50.13%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :260.2/260.2 Hz   T2[0] : 0.0/14.8 Hz   T3[0] : 0.0/16.9 Hz   T4[0] : 0.0/14.1 Hz   T5[0] : 0.0/47.6 Hz   T6[0] : 0.0/9.5  Hz   T7[0] : 0.1/9052.2 Hz   T8[0] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 506397/506397   T2[0] :      0/28885    T3[0] :      0/32834    T4[0] :      0/27514    T5[0] :      1/92633    T6[0] :      0/18425    T7[0] :    268/17617188  T8[0] :     30/1992878  
    
    AVERAGE CURRENT
    BCM x1 : 2.4873 uA  BCM x3 : 0.5881 uA  BCM x10: 2.5819 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:-0.0002974     BCM u3 [0]:0.002322       BCM u10[0]:-3.755E-05     
    
    BCM d1 [0]:0.009979       BCM d3 [0]:-3.28E-05      BCM d10[0]:0.01009        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4833 at Sat Nov 7 08:57:21 EST 2009
    
    Left Arm Top VDC Current : 0.732422
    Left Arm Bottom VDC Current : -0.732422
    Left Arm Top VDC voltage : 3.99658
    Left Arm Bottom VDC voltage : 4
    -----
    Right Arm Top VDC Current : -29.541
    Right Arm Bottom VDC Current : -3.27148
    Right Arm Top VDC voltage : 3.99268
    Right Arm Bottom VDC voltage : 4.02051
    -----
    Left Arm Q1 momentum : 3.66036
    Left Arm Q1 power supply : 2753.75
    Left Arm Q1 gauss meter : -0.23213
    Left Arm Q2 gauss meter : 0.8272
    Left Arm Q2 power supply current : 1575.83
    Left Arm Q2 momentum : 3.65962
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.22
    Left Arm D1 momentum : 3.66007
    Left Arm D1 NMR : 1.35577
    Left Arm arm angle : 12.8988
    Left Arm Q3 gauss meter : -0.73458
    Left Arm Q3 power supply current : 1457.2
    Left Arm Q3 momentum : 3.66021
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 2.62965
    Right Arm Q1 power supply : 1977.38
    Right Arm Q1 gauss meter : -0.04909
    Right Arm Q2 power supply current : 1132.1
    Right Arm Q2 momentum : 2.63055
    Right Arm Q2 gauss meter : 0.5924
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 932.84
    Right Arm D1 momentum : 2.62998
    Right Arm D1 NMR : 0.975955
    Right Arm arm angle : 20.001
    Right Arm Q3 power supply current : 1046.63
    Right Arm Q3 momentum : 2.63033
    Right Arm Q3 gauss meter : 0.4684
    Right Arm Q3 power supply polarity : disabled
    -----
    Average current of the two cavities : 5.56297
    Current on Unser monitor : 22.8317
    Current on Upstream bcm : 5.41795
    Current on Downstream bcm : 5.70798
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 5.76004
    Hall C Current : 0
    MBSY1c magnet current (amp) : 254.343
    MBSY1c Bdl : 1.51764e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.38
    Hall A momentum orbit correction (dpp) : -1.22466e-05
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6067.38
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 0.761379
    IPM1C12.XPOS : -0.000741661
    IPM1H04A.XPOS : -2.88117
    IPM1H04A.YPOS : 1.91813
    IPM1H04B.XPOS : -3.00221
    IPM1H04B.YPOS : 1.99293
    -----
    Wien angle : 74.7279
    Wien BDL : 1724.8
    Wien field : 49.796
    Laser attenuation Hall A : 66
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    -----
    Target : Optics
    fan frequency loop 1 : 60
    fan frequency loop 3 : 0
    Encoder position : 1.26745e+07
    Target type : 1.26745e+07
    temperature loop 1(1) : 22.01
    temperature loop 1(2) : 21.96
    temperature loop 1(3) : 22.28
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.5
    Heat exchange LH2 : 273.2
    HPH H2 loop 1 : 1100.92
    HPH H2 loop 3 : 9.38936e-06