     Run Number: 25305
     End of Run Comment:
    Run_type=Check out,target_type=Optics,targetpol_poldir=Longitudinal,targetpol_pol=87,beam_e0=6.0,beam_raster=on,beam_current=5.0,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=19.0,rightarm_sieve=out,comment_text=Optics run. raster off, both sieves out
     
    
    PRESCALE FACTORS:ps1=1   ps2=99999   ps3=99999   ps4=99999   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 5474         
    TIME     : [0]: 10.297 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  -6.21%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 6.0/6.0  Hz   T2[0] : 0.0/5.6  Hz   T3[0] : 0.0/1.1  Hz   T4[0] : 2.2/223376.4 Hz   T5[0] : 1.0/68552.5 Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.1/4034.8 Hz   T8[0] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   3726/3726     T2[0] :      0/3441     T3[0] :      0/665      T4[0] :   1380/138007155  T5[0] :    646/42353355  T6[0] :      0/0        T7[0] :     38/2492766  T8[0] :      9/632651   
    
    AVERAGE CURRENT
    BCM x1 : 0.0004 uA  BCM x3 : -0.0320uA  BCM x10: 0.0020 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:2.673E-07      BCM u3 [0]:-2.915E-05     BCM u10[0]:3.864E-06      
    
    BCM d1 [0]:1.909E-07      BCM d3 [0]:-1.041E-05     BCM d10[0]:-1.384E-06     
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 25305 at Sat Nov 7 10:41:51 EST 2009
    
    Left Arm Top VDC Current : -0.878906
    Left Arm Bottom VDC Current : 0.341797
    Left Arm Top VDC voltage : 3.99512
    Left Arm Bottom VDC voltage : 4.00195
    -----
    Right Arm Top VDC Current : -21.7773
    Right Arm Bottom VDC Current : -1.5625
    Right Arm Top VDC voltage : 3.99561
    Right Arm Bottom VDC voltage : 4.0127
    -----
    Left Arm Q1 momentum : 3.66036
    Left Arm Q1 power supply : 2753.86
    Left Arm Q1 gauss meter : -0.23216
    Left Arm Q2 gauss meter : 0.8272
    Left Arm Q2 power supply current : 1575.85
    Left Arm Q2 momentum : 3.65967
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.23
    Left Arm D1 momentum : 3.66008
    Left Arm D1 NMR : 1.35577
    Left Arm arm angle : 12.8988
    Left Arm Q3 gauss meter : -0.73459
    Left Arm Q3 power supply current : 1457.2
    Left Arm Q3 momentum : 3.66022
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 2.62965
    Right Arm Q1 power supply : 1977.33
    Right Arm Q1 gauss meter : -0.04911
    Right Arm Q2 power supply current : 1132.11
    Right Arm Q2 momentum : 2.63056
    Right Arm Q2 gauss meter : 0.5924
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 932.84
    Right Arm D1 momentum : 2.62997
    Right Arm D1 NMR : 0.975951
    Right Arm arm angle : 20.001
    Right Arm Q3 power supply current : 1046.64
    Right Arm Q3 momentum : 2.63034
    Right Arm Q3 gauss meter : 0.4684
    Right Arm Q3 power supply polarity : disabled
    -----
    Average current of the two cavities : 0.0256218
    Current on Unser monitor : 17.6363
    Current on Upstream bcm : 0.0378062
    Current on Downstream bcm : 0.0134374
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 0.150236
    Hall C Current : 0
    MBSY1c magnet current (amp) : 0.0377197
    MBSY1c Bdl : 1.51764e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.46
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6067.46
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 0.761379
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Wien angle : 74.7279
    Wien BDL : 1724.8
    Wien field : 49.796
    Laser attenuation Hall A : 60
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    -----
    Target : Optics
    fan frequency loop 1 : 60
    fan frequency loop 3 : 0
    Encoder position : 1.26745e+07
    Target type : 1.26745e+07
    temperature loop 1(1) : 22.02
    temperature loop 1(2) : 21.97
    temperature loop 1(3) : 22.29
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.5
    Heat exchange LH2 : 273.2
    HPH H2 loop 1 : 1104.43
    HPH H2 loop 3 : 0.00230457