End-of-run EPICS data for Run Number 4836 at Sat Nov 7 14:44:07 EST 2009
Left Arm Top VDC Current : -1.46484
Left Arm Bottom VDC Current : 4.63867
Left Arm Top VDC voltage : 3.99219
Left Arm Bottom VDC voltage : 3.99902
-----
Right Arm Top VDC Current : -8.74023
Right Arm Bottom VDC Current : -2.14844
Right Arm Top VDC voltage : 3.99463
Right Arm Bottom VDC voltage : 4.00342
-----
Left Arm Q1 momentum : 3.66029
Left Arm Q1 power supply : 2753.75
Left Arm Q1 gauss meter : -0.23215
Left Arm Q2 gauss meter : 0.8272
Left Arm Q2 power supply current : 1575.85
Left Arm Q2 momentum : 3.65965
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1325.22
Left Arm D1 momentum : 3.66007
Left Arm D1 NMR : 1.35577
Left Arm arm angle : 12.8988
Left Arm Q3 gauss meter : -0.7346
Left Arm Q3 power supply current : 1457.21
Left Arm Q3 momentum : 3.66023
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 2.62965
Right Arm Q1 power supply : 1977.38
Right Arm Q1 gauss meter : -0.04911
Right Arm Q2 power supply current : 1132.11
Right Arm Q2 momentum : 2.63056
Right Arm Q2 gauss meter : 0.5924
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 932.841
Right Arm D1 momentum : 2.62993
Right Arm D1 NMR : 0.975935
Right Arm arm angle : 20.001
Right Arm Q3 power supply current : 1046.64
Right Arm Q3 momentum : 2.63034
Right Arm Q3 gauss meter : 0.4684
Right Arm Q3 power supply polarity : disabled
-----
Average current of the two cavities : 9.71591
Current on Unser monitor : 28.073
Current on Upstream bcm : 9.46545
Current on Downstream bcm : 9.96637
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 9.84749
Hall C Current : 0
MBSY1c magnet current (amp) : 254.343
MBSY1c Bdl : 1.51764e+06
Hall A momentum (Tiefenbach) (HALLA:p) : 6067.38
Hall A momentum orbit correction (dpp) : -1.3345e-05
Hall A setup momentum (MMSHLAE) : 6067.5
Hall A energy (halla_MeV) : 6067.38
Hall C energy (hallc_MeV) : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 0.761379
IPM1C12.XPOS : 0.000513285
IPM1H04A.XPOS : -2.90582
IPM1H04A.YPOS : 1.96387
IPM1H04B.XPOS : -3.003
IPM1H04B.YPOS : 1.99997
-----
Wien angle : 74.7279
Wien BDL : 1724.8
Wien field : 49.796
Laser attenuation Hall A : 72
Laser power Hall A : 100
Half-wave plate (off=out) : OUT
rotating waveplate : 1200
Beam Half-wave plate (off=out) : OUT
-----
Helicity Settle Read : 500
Helicity Delay Read : 8 cycles
Helicity Pattern : Quartet
-----
Target : Optics
fan frequency loop 1 : 59.5
fan frequency loop 3 : 0
Encoder position : 1.26745e+07
Target type : 1.26745e+07
temperature loop 1(1) : 21.99
temperature loop 1(2) : 21.94
temperature loop 1(3) : 22.26
temperature loop 3(1) : 99.99
temperature loop 3(2) : 99.99
temperature loop 3(3) : 29.99
Heat exchange LH2 : 24.5
Heat exchange LH2 : 273.3
HPH H2 loop 1 : 1179.33
HPH H2 loop 3 : 9.38936e-06