Privacy and Security Notice

End_of_Run_4839


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 16:24:57 on November 7, 2009

    Entry number 298120

    keyword=End_of_Run_4839
    ****************************
     Run Number: 4839
     End of Run Comment:
    Run_type=Check out,target_type=Optics,beam_e0=6.06,beam_raster=on,beam_current=10,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=20,rightarm_sieve=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=1   ps2=16777215   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 506765       
    TIME     : [0]: 7.953 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  65.51%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :3078.5/3078.5 Hz   T2[0] : 0.0/129.0 Hz   T3[0] : 0.0/86.7 Hz   T4[0] : 0.0/25.6 Hz   T5[0] : 0.0/119.2 Hz   T6[0] : 0.0/83.0 Hz   T7[0] : 0.4/24476.8 Hz   T8[0] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :1469060/1469060  T2[0] :      0/61567    T3[0] :      0/41369    T4[0] :      0/12205    T5[0] :      0/56880    T6[0] :      0/39607    T7[0] :    178/11680214  T8[0] :      7/488648   
    
    AVERAGE CURRENT
    BCM x1 : 23.0428uA  BCM x3 : 1.6453 uA  BCM x10: 13.8649uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:-7.292E-05     BCM u3 [0]:0.001578       BCM u10[0]:-7.696E-06     
    
    BCM d1 [0]:0.02206        BCM d3 [0]:-8.043E-06     BCM d10[0]:0.01324        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4839 at Sat Nov 7 16:24:53 EST 2009
    
    Left Arm Top VDC Current : 1.41602
    Left Arm Bottom VDC Current : 2.34375
    Left Arm Top VDC voltage : 1.03418
    Left Arm Bottom VDC voltage : 1.09033
    -----
    Right Arm Top VDC Current : 3.85742
    Right Arm Bottom VDC Current : -0.732422
    Right Arm Top VDC voltage : 0.871094
    Right Arm Bottom VDC voltage : 0.974609
    -----
    Left Arm Q1 momentum : 3.66029
    Left Arm Q1 power supply : 2753.75
    Left Arm Q1 gauss meter : -0.23216
    Left Arm Q2 gauss meter : 0.8272
    Left Arm Q2 power supply current : 1575.85
    Left Arm Q2 momentum : 3.65965
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.22
    Left Arm D1 momentum : 3.66007
    Left Arm D1 NMR : 1.35577
    Left Arm arm angle : 12.8988
    Left Arm Q3 gauss meter : -0.73456
    Left Arm Q3 power supply current : 1457.19
    Left Arm Q3 momentum : 3.66018
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 2.62965
    Right Arm Q1 power supply : 1977.33
    Right Arm Q1 gauss meter : -0.04908
    Right Arm Q2 power supply current : 1132.1
    Right Arm Q2 momentum : 2.63054
    Right Arm Q2 gauss meter : 0.5924
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 932.84
    Right Arm D1 momentum : 2.62998
    Right Arm D1 NMR : 0.975954
    Right Arm arm angle : 20.001
    Right Arm Q3 power supply current : 1046.63
    Right Arm Q3 momentum : 2.63032
    Right Arm Q3 gauss meter : 0.4684
    Right Arm Q3 power supply polarity : disabled
    -----
    Average current of the two cavities : 0.0311125
    Current on Unser monitor : 17.254
    Current on Upstream bcm : 0.0378224
    Current on Downstream bcm : 0.0244026
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 0.00850698
    Hall C Current : 0
    MBSY1c magnet current (amp) : 254.343
    MBSY1c Bdl : 1.51764e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.46
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6067.46
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 0.761379
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Wien angle : 74.7279
    Wien BDL : 1724.8
    Wien field : 49.796
    Laser attenuation Hall A : 123
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    -----
    Target : Carbon Hole
    fan frequency loop 1 : 60
    fan frequency loop 3 : 0
    Encoder position : 9.05468e+06
    Target type : 9.05468e+06
    temperature loop 1(1) : 21.99
    temperature loop 1(2) : 21.94
    temperature loop 1(3) : 22.26
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.5
    Heat exchange LH2 : 273.3
    HPH H2 loop 1 : 1122.04
    HPH H2 loop 3 : 9.38936e-06