Privacy and Security Notice

End_of_Run_4840


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 16:27:19 on November 7, 2009

    Entry number 298123

    keyword=End_of_Run_4840
    ****************************
     Run Number: 4840
     End of Run Comment:
    Run_type=Check out,target_type=Optics,beam_e0=6.06,beam_raster=on,beam_current=10,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=20,rightarm_sieve=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=1   ps2=16777215   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 9554         
    TIME     : [0]: 0.299 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  85.38%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :3645.0/3645.0 Hz   T2[0] : 0.0/144.2 Hz   T3[0] : 0.0/104.7 Hz   T4[0] : 0.0/30.1 Hz   T5[0] : 0.0/141.4 Hz   T6[0] : 0.0/69.9 Hz   T7[0] : 0.4/26367.5 Hz   T8[0] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  65353/65353    T2[0] :      0/2585     T3[0] :      0/1877     T4[0] :      0/540      T5[0] :      0/2536     T6[0] :      0/1254     T7[0] :      7/472761   T8[0] :      0/18360    
    
    AVERAGE CURRENT
    BCM x1 : 27.4009uA  BCM x3 : 1.7749 uA  BCM x10: 21.8275uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:-2.74E-06      BCM u3 [0]:6.395E-05      BCM u10[0]:-2.746E-07     
    
    BCM d1 [0]:0.0009853      BCM d3 [0]:-3.022E-07     BCM d10[0]:0.000783       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4840 at Sat Nov 7 16:27:16 EST 2009
    
    Left Arm Top VDC Current : 1.46484
    Left Arm Bottom VDC Current : 1.51367
    Left Arm Top VDC voltage : 0.0180664
    Left Arm Bottom VDC voltage : 0.019043
    -----
    Right Arm Top VDC Current : -1.70898
    Right Arm Bottom VDC Current : -1.46484
    Right Arm Top VDC voltage : -0.012207
    Right Arm Bottom VDC voltage : 0.00244141
    -----
    Left Arm Q1 momentum : 3.66029
    Left Arm Q1 power supply : 2753.75
    Left Arm Q1 gauss meter : -0.23215
    Left Arm Q2 gauss meter : 0.8273
    Left Arm Q2 power supply current : 1575.85
    Left Arm Q2 momentum : 3.65966
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.23
    Left Arm D1 momentum : 3.66007
    Left Arm D1 NMR : 1.35577
    Left Arm arm angle : 12.8988
    Left Arm Q3 gauss meter : -0.73459
    Left Arm Q3 power supply current : 1457.19
    Left Arm Q3 momentum : 3.6602
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 2.62972
    Right Arm Q1 power supply : 1977.33
    Right Arm Q1 gauss meter : -0.04911
    Right Arm Q2 power supply current : 1132.1
    Right Arm Q2 momentum : 2.63055
    Right Arm Q2 gauss meter : 0.5925
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 932.841
    Right Arm D1 momentum : 2.62998
    Right Arm D1 NMR : 0.975955
    Right Arm arm angle : 20.001
    Right Arm Q3 power supply current : 1046.63
    Right Arm Q3 momentum : 2.63033
    Right Arm Q3 gauss meter : 0.4683
    Right Arm Q3 power supply polarity : disabled
    -----
    Average current of the two cavities : 93.6327
    Current on Unser monitor : 115.799
    Current on Upstream bcm : 85.2315
    Current on Downstream bcm : 102.034
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 87.6433
    Hall C Current : 0
    MBSY1c magnet current (amp) : 254.343
    MBSY1c Bdl : 1.51764e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.73
    Hall A momentum orbit correction (dpp) : 4.50294e-05
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6067.73
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 0.761379
    IPM1C12.XPOS : -0.669174
    IPM1H04A.XPOS : -2.89996
    IPM1H04A.YPOS : 2.04844
    IPM1H04B.XPOS : -3.01352
    IPM1H04B.YPOS : 2.12046
    -----
    Wien angle : 74.7279
    Wien BDL : 1724.8
    Wien field : 49.796
    Laser attenuation Hall A : 120
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    -----
    Target : Carbon Hole
    fan frequency loop 1 : 59.5
    fan frequency loop 3 : 0
    Encoder position : 9.05468e+06
    Target type : 9.05468e+06
    temperature loop 1(1) : 21.99
    temperature loop 1(2) : 21.95
    temperature loop 1(3) : 22.26
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.5
    Heat exchange LH2 : 273.3
    HPH H2 loop 1 : 1134.45
    HPH H2 loop 3 : 0.011068