Privacy and Security Notice

End_of_Run_4841


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 16:38:26 on November 7, 2009

    Entry number 298129

    keyword=End_of_Run_4841
    ****************************
     Run Number: 4841
     End of Run Comment:
    Run_type=Check out,target_type=Optics,beam_e0=6.06,beam_raster=on,beam_current=10,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=20,rightarm_sieve=out,comment_text=R arm detector check
     
    
    PRESCALE FACTORS:ps1=1000   ps2=16777215   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 2750         
    TIME     : [0]: 9.101 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]: -35.32%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 3.3/3304.7 Hz   T2[0] : 0.0/135.8 Hz   T3[0] : 0.0/93.2 Hz   T4[0] : 0.0/26.8 Hz   T5[0] : 0.0/127.1 Hz   T6[0] : 0.0/65.4 Hz   T7[0] : 0.4/26104.3 Hz   T8[0] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   1804/1804598  T2[0] :      0/74133    T3[0] :      0/50885    T4[0] :      0/14611    T5[0] :      1/69422    T6[0] :      0/35687    T7[0] :    217/14254817  T8[0] :      8/559178   
    
    AVERAGE CURRENT
    BCM x1 : 24.6280uA  BCM x3 : 1.7569 uA  BCM x10: 13.7903uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:-8.344E-05     BCM u3 [0]:0.001928       BCM u10[0]:-8.647E-06     
    
    BCM d1 [0]:0.02698        BCM d3 [0]:-9.204E-06     BCM d10[0]:0.01507        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4841 at Sat Nov 7 16:38:23 EST 2009
    
    Left Arm Top VDC Current : 1.51367
    Left Arm Bottom VDC Current : 1.41602
    Left Arm Top VDC voltage : 0.0175781
    Left Arm Bottom VDC voltage : 0.019043
    -----
    Right Arm Top VDC Current : -1.70898
    Right Arm Bottom VDC Current : -1.41602
    Right Arm Top VDC voltage : -0.0126953
    Right Arm Bottom VDC voltage : 0.00292969
    -----
    Left Arm Q1 momentum : 3.66029
    Left Arm Q1 power supply : 2753.75
    Left Arm Q1 gauss meter : -0.23216
    Left Arm Q2 gauss meter : 0.8273
    Left Arm Q2 power supply current : 1575.85
    Left Arm Q2 momentum : 3.65966
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.23
    Left Arm D1 momentum : 3.66008
    Left Arm D1 NMR : 1.35577
    Left Arm arm angle : 12.8988
    Left Arm Q3 gauss meter : -0.73457
    Left Arm Q3 power supply current : 1457.19
    Left Arm Q3 momentum : 3.66019
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 2.62972
    Right Arm Q1 power supply : 1977.38
    Right Arm Q1 gauss meter : -0.0491
    Right Arm Q2 power supply current : 1132.1
    Right Arm Q2 momentum : 2.63055
    Right Arm Q2 gauss meter : 0.5924
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 932.84
    Right Arm D1 momentum : 2.62998
    Right Arm D1 NMR : 0.975956
    Right Arm arm angle : 20.001
    Right Arm Q3 power supply current : 1046.63
    Right Arm Q3 momentum : 2.63033
    Right Arm Q3 gauss meter : 0.4684
    Right Arm Q3 power supply polarity : disabled
    -----
    Average current of the two cavities : 109.536
    Current on Unser monitor : 126.516
    Current on Upstream bcm : 107.02
    Current on Downstream bcm : 112.053
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 110.032
    Hall C Current : 0
    MBSY1c magnet current (amp) : 254.343
    MBSY1c Bdl : 1.51764e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.38
    Hall A momentum orbit correction (dpp) : -1.26426e-05
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6067.38
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 0.761379
    IPM1C12.XPOS : 0.00448471
    IPM1H04A.XPOS : -2.91477
    IPM1H04A.YPOS : 2.01536
    IPM1H04B.XPOS : -3.01755
    IPM1H04B.YPOS : 2.04817
    -----
    Wien angle : 74.7279
    Wien BDL : 1724.8
    Wien field : 49.796
    Laser attenuation Hall A : 123
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    -----
    Target : Carbon Hole
    fan frequency loop 1 : 60
    fan frequency loop 3 : 0
    Encoder position : 9.05468e+06
    Target type : 9.05468e+06
    temperature loop 1(1) : 22
    temperature loop 1(2) : 21.96
    temperature loop 1(3) : 22.28
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.5
    Heat exchange LH2 : 273.4
    HPH H2 loop 1 : 1170.28
    HPH H2 loop 3 : 0.0170928