    Log entry time 16:38:27 on November 7, 2009

    Entry number 298130

    keyword=End_of_Run_25314
    ****************************
     Run Number: 25314
     End of Run Comment:
    Run_type=Check out,target_type=Optics,beam_e0=6.06,beam_raster=on,beam_current=10,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=20.0,rightarm_sieve=out,comment_text=left arm detector check
     
    
    PRESCALE FACTORS:ps1=2000   ps2=99999   ps3=99999   ps4=99999   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 2537         
    TIME     : [0]: 9.070 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:   2.13%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 4.5/8987.5 Hz   T2[0] : 0.0/110.8 Hz   T3[0] : 0.0/0.2  Hz   T4[0] : 0.0/0.1  Hz   T5[0] : 0.0/516.6 Hz   T6[0] : 0.0/2.3  Hz   T7[0] : 0.2/16047.5 Hz   T8[0] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   2445/4891142  T2[0] :      0/60297    T3[0] :      0/91       T4[0] :      0/71       T5[0] :      4/281166   T6[0] :      0/1272     T7[0] :    133/8733335  T8[0] :      8/557278   
    
    AVERAGE CURRENT
    BCM x1 : 49.2265uA  BCM x3 : 0.5836 uA  BCM x10: 28.2410uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.02678        BCM u3 [0]:0.0006444      BCM u10[0]:0.01576        
    
    BCM d1 [0]:0.0268         BCM d3 [0]:-9.172E-06     BCM d10[0]:0.01498        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 25314 at Sat Nov 7 16:38:24 EST 2009
    
    Left Arm Top VDC Current : 1.51367
    Left Arm Bottom VDC Current : 1.41602
    Left Arm Top VDC voltage : 0.0175781
    Left Arm Bottom VDC voltage : 0.019043
    -----
    Right Arm Top VDC Current : -1.70898
    Right Arm Bottom VDC Current : -1.41602
    Right Arm Top VDC voltage : -0.0126953
    Right Arm Bottom VDC voltage : 0.00292969
    -----
    Left Arm Q1 momentum : 3.66029
    Left Arm Q1 power supply : 2753.75
    Left Arm Q1 gauss meter : -0.23216
    Left Arm Q2 gauss meter : 0.8272
    Left Arm Q2 power supply current : 1575.85
    Left Arm Q2 momentum : 3.65966
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.22
    Left Arm D1 momentum : 3.66008
    Left Arm D1 NMR : 1.35577
    Left Arm arm angle : 12.8988
    Left Arm Q3 gauss meter : -0.73458
    Left Arm Q3 power supply current : 1457.19
    Left Arm Q3 momentum : 3.66019
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 2.62972
    Right Arm Q1 power supply : 1977.38
    Right Arm Q1 gauss meter : -0.04911
    Right Arm Q2 power supply current : 1132.1
    Right Arm Q2 momentum : 2.63055
    Right Arm Q2 gauss meter : 0.5924
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 932.841
    Right Arm D1 momentum : 2.62998
    Right Arm D1 NMR : 0.975956
    Right Arm arm angle : 20.001
    Right Arm Q3 power supply current : 1046.63
    Right Arm Q3 momentum : 2.63033
    Right Arm Q3 gauss meter : 0.4684
    Right Arm Q3 power supply polarity : disabled
    -----
    Average current of the two cavities : 109.536
    Current on Unser monitor : 126.516
    Current on Upstream bcm : 107.02
    Current on Downstream bcm : 112.053
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 110.197
    Hall C Current : 0
    MBSY1c magnet current (amp) : 254.343
    MBSY1c Bdl : 1.51764e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.39
    Hall A momentum orbit correction (dpp) : -1.05693e-05
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6067.39
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 0.761379
    IPM1C12.XPOS : 0.00448471
    IPM1H04A.XPOS : -2.89307
    IPM1H04A.YPOS : 2.0446
    IPM1H04B.XPOS : -2.98778
    IPM1H04B.YPOS : 2.08055
    -----
    Wien angle : 74.7279
    Wien BDL : 1724.8
    Wien field : 49.796
    Laser attenuation Hall A : 123
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    -----
    Target : Carbon Hole
    fan frequency loop 1 : 60
    fan frequency loop 3 : 0
    Encoder position : 9.05468e+06
    Target type : 9.05468e+06
    temperature loop 1(1) : 22
    temperature loop 1(2) : 21.96
    temperature loop 1(3) : 22.28
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.5
    Heat exchange LH2 : 273.4
    HPH H2 loop 1 : 1170.28
    HPH H2 loop 3 : 0.0170928