Log entry time 16:59:54 on November 7, 2009
Entry number 298133
keyword=End_of_Run_25315
****************************
Run Number: 25315
End of Run Comment:
Run_type=Check out,target_type=Optics,beam_e0=6.06,beam_raster=on,beam_current=10,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=20.0,rightarm_sieve=out,comment_text=left arm detector check
PRESCALE FACTORS:ps1=20 ps2=99999 ps3=99999 ps4=99999 ps5=65535 ps6=65535 ps7=65535 ps8=65535
EVENTS : [0]: 1013642
TIME : [0]: 20.151 mins
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: -0.30%
TRIGGER RATES: PRES/REAL
T1[0] :835.5/16709.5 Hz T2[0] : 0.0/205.4 Hz T3[0] : 0.0/0.4 Hz T4[0] : 0.0/0.3 Hz T5[0] : 0.0/1009.1 Hz T6[0] : 0.0/5.2 Hz T7[0] : 0.4/25934.7 Hz T8[0] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] :1010127/20202545 T2[0] : 2/248343 T3[0] : 0/427 T4[0] : 0/319 T5[0] : 18/1220065 T6[0] : 0/6249 T7[0] : 478/31356174 T8[0] : 18/1238060
AVERAGE CURRENT
BCM x1 : 91.5980uA BCM x3 : 1.1129 uA BCM x10: 45.2520uA
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.1108 BCM u3 [0]:0.002712 BCM u10[0]:0.05653
BCM d1 [0]:0.1107 BCM d3 [0]:-2.038E-05 BCM d10[0]:0.05289
****************************
End-of-run EPICS data for Run Number 25315 at Sat Nov 7 16:59:51 EST 2009
Left Arm Top VDC Current : 1.41602
Left Arm Bottom VDC Current : 1.46484
Left Arm Top VDC voltage : 0.0180664
Left Arm Bottom VDC voltage : 0.0180664
-----
Right Arm Top VDC Current : -1.70898
Right Arm Bottom VDC Current : -1.36719
Right Arm Top VDC voltage : -0.0126953
Right Arm Bottom VDC voltage : 0.00244141
-----
Left Arm Q1 momentum : 3.66036
Left Arm Q1 power supply : 2753.8
Left Arm Q1 gauss meter : -0.23216
Left Arm Q2 gauss meter : 0.8273
Left Arm Q2 power supply current : 1575.85
Left Arm Q2 momentum : 3.65966
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1325.23
Left Arm D1 momentum : 3.66007
Left Arm D1 NMR : 1.35577
Left Arm arm angle : 12.8988
Left Arm Q3 gauss meter : -0.73457
Left Arm Q3 power supply current : 1457.19
Left Arm Q3 momentum : 3.6602
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 2.62972
Right Arm Q1 power supply : 1977.38
Right Arm Q1 gauss meter : -0.04912
Right Arm Q2 power supply current : 1132.1
Right Arm Q2 momentum : 2.63055
Right Arm Q2 gauss meter : 0.5924
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 932.841
Right Arm D1 momentum : 2.62997
Right Arm D1 NMR : 0.975952
Right Arm arm angle : 20.001
Right Arm Q3 power supply current : 1046.63
Right Arm Q3 momentum : 2.63034
Right Arm Q3 gauss meter : 0.4683
Right Arm Q3 power supply polarity : disabled
-----
Average current of the two cavities : 0.0295748
Current on Unser monitor : 17.1179
Current on Upstream bcm : 0.0350914
Current on Downstream bcm : 0.0240582
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.01057
Hall C Current : 0
MBSY1c magnet current (amp) : 254.343
MBSY1c Bdl : 1.51764e+06
Hall A momentum (Tiefenbach) (HALLA:p) : 6067.46
Hall A momentum orbit correction (dpp) : 0
Hall A setup momentum (MMSHLAE) : 6067.5
Hall A energy (halla_MeV) : 6067.46
Hall C energy (hallc_MeV) : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 0.761379
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
-----
Wien angle : 74.7279
Wien BDL : 1724.8
Wien field : 49.796
Laser attenuation Hall A : 60
Laser power Hall A : 100
Half-wave plate (off=out) : OUT
rotating waveplate : 1200
Beam Half-wave plate (off=out) : OUT
-----
Helicity Settle Read : 500
Helicity Delay Read : 8 cycles
Helicity Pattern : Quartet
-----
Target : Carbon Hole
fan frequency loop 1 : 60
fan frequency loop 3 : 0
Encoder position : 9.05468e+06
Target type : 9.05468e+06
temperature loop 1(1) : 21.99
temperature loop 1(2) : 21.95
temperature loop 1(3) : 22.27
temperature loop 3(1) : 99.99
temperature loop 3(2) : 99.99
temperature loop 3(3) : 29.99
Heat exchange LH2 : 24.5
Heat exchange LH2 : 273.4
HPH H2 loop 1 : 1111.45
HPH H2 loop 3 : 0.000504939