Entry number 298161
keyword=End_of_Run_25319
****************************
Run Number: 25319
End of Run Comment:
Run_type=Check out,target_type=Alum Dummy w/ Hole,beam_e0=6.06,beam_raster=on,beam_current=10,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=20.0,rightarm_sieve=out,comment_text=raster @ carbon hole
PRESCALE FACTORS:ps1=2 ps2=99999 ps3=99999 ps4=99999 ps5=65535 ps6=65535 ps7=65535 ps8=65535
EVENTS : [0]: 115398
TIME : [0]: 1.456 mins
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 17.05%
TRIGGER RATES: PRES/REAL
T1[0] :1592.7/3185.5 Hz T2[0] : 0.0/42.3 Hz T3[0] : 0.0/0.1 Hz T4[0] : 0.0/0.1 Hz T5[0] : 0.0/214.6 Hz T6[0] : 0.0/0.1 Hz T7[0] : 0.1/7954.3 Hz T8[0] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 139115/278230 T2[0] : 0/3696 T3[0] : 0/6 T4[0] : 0/5 T5[0] : 0/18747 T6[0] : 0/13 T7[0] : 10/694756 T8[0] : 1/89440
AVERAGE CURRENT
BCM x1 : 5.4706 uA BCM x3 : 0.1859 uA BCM x10: 5.5255 uA
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.0004762 BCM u3 [0]:3.395E-05 BCM u10[0]:0.0004806
BCM d1 [0]:0.0004795 BCM d3 [0]:-1.472E-06 BCM d10[0]:0.0004847
****************************
End-of-run EPICS data for Run Number 25319 at Sat Nov 7 18:24:55 EST 2009
Left Arm Top VDC Current : 0.0976562
Left Arm Bottom VDC Current : 2.73438
Left Arm Top VDC voltage : 3.99561
Left Arm Bottom VDC voltage : 4.00049
-----
Right Arm Top VDC Current : 26.0254
Right Arm Bottom VDC Current : -3.36914
Right Arm Top VDC voltage : 3.99902
Right Arm Bottom VDC voltage : 3.99219
-----
Left Arm Q1 momentum : 3.66036
Left Arm Q1 power supply : 2753.8
Left Arm Q1 gauss meter : -0.23214
Left Arm Q2 gauss meter : 0.8272
Left Arm Q2 power supply current : 1575.85
Left Arm Q2 momentum : 3.65966
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1325.23
Left Arm D1 momentum : 3.66007
Left Arm D1 NMR : 1.35577
Left Arm arm angle : 12.8988
Left Arm Q3 gauss meter : -0.73457
Left Arm Q3 power supply current : 1457.19
Left Arm Q3 momentum : 3.66019
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 2.62972
Right Arm Q1 power supply : 1977.38
Right Arm Q1 gauss meter : -0.0491
Right Arm Q2 power supply current : 1132.1
Right Arm Q2 momentum : 2.63055
Right Arm Q2 gauss meter : 0.5924
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 932.84
Right Arm D1 momentum : 2.62996
Right Arm D1 NMR : 0.975945
Right Arm arm angle : 20.001
Right Arm Q3 power supply current : 1046.64
Right Arm Q3 momentum : 2.63034
Right Arm Q3 gauss meter : 0.4684
Right Arm Q3 power supply polarity : disabled
-----
Average current of the two cavities : 5.54743
Current on Unser monitor : 23.331
Current on Upstream bcm : 5.40324
Current on Downstream bcm : 5.69161
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 5.70132
Hall C Current : 0
MBSY1c magnet current (amp) : 254.343
MBSY1c Bdl : 1.51764e+06
Hall A momentum (Tiefenbach) (HALLA:p) : 6067.4
Hall A momentum orbit correction (dpp) : -9.39388e-06
Hall A setup momentum (MMSHLAE) : 6067.5
Hall A energy (halla_MeV) : 6067.4
Hall C energy (hallc_MeV) : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 0.761379
IPM1C12.XPOS : -0.0043489
IPM1H04A.XPOS : -2.90567
IPM1H04A.YPOS : 1.9882
IPM1H04B.XPOS : -2.99448
IPM1H04B.YPOS : 2.03343
-----
Wien angle : 74.7279
Wien BDL : 1724.8
Wien field : 49.796
Laser attenuation Hall A : 66
Laser power Hall A : 100
Half-wave plate (off=out) : OUT
rotating waveplate : 1200
Beam Half-wave plate (off=out) : OUT
-----
Helicity Settle Read : 500
Helicity Delay Read : 8 cycles
Helicity Pattern : Quartet
-----
Target : Dummy Hole
fan frequency loop 1 : 59.5
fan frequency loop 3 : 0
Encoder position : 1.21266e+07
Target type : 1.21266e+07
temperature loop 1(1) : 22.01
temperature loop 1(2) : 21.96
temperature loop 1(3) : 22.28
temperature loop 3(1) : 99.99
temperature loop 3(2) : 99.99
temperature loop 3(3) : 29.99
Heat exchange LH2 : 24.5
Heat exchange LH2 : 273.4
HPH H2 loop 1 : 1088.69
HPH H2 loop 3 : 0.00634721