Privacy and Security Notice

End_of_Run_4848


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 18:39:56 on November 7, 2009

    Entry number 298166

    keyword=End_of_Run_4848
    ****************************
     Run Number: 4848
     End of Run Comment:
    Run_type=Check out,target_type=LD2, 20cm,beam_e0=6.06,beam_raster=on,beam_current=110,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=20,rightarm_sieve=out,comment_text=position survey
     
    
    PRESCALE FACTORS:ps1=2   ps2=16777215   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 83608        
    TIME     : [0]: 1.951 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  55.68%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :1611.6/3223.2 Hz   T2[0] : 0.0/80.0 Hz   T3[0] : 0.0/56.4 Hz   T4[0] : 0.0/17.4 Hz   T5[0] : 0.0/80.3 Hz   T6[0] : 0.0/36.8 Hz   T7[0] : 0.3/20042.4 Hz   T8[0] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 188621/377242   T2[0] :      0/9366     T3[0] :      0/6601     T4[0] :      0/2031     T5[0] :      0/9404     T6[0] :      0/4312     T7[0] :     35/2345740  T8[0] :      1/119848   
    
    AVERAGE CURRENT
    BCM x1 : 0.8104 uA  BCM x3 : 1.3414 uA  BCM x10: 0.8873 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:-1.788E-05     BCM u3 [0]:0.000316       BCM u10[0]:-2.048E-06     
    
    BCM d1 [0]:0.0002076      BCM d3 [0]:-1.973E-06     BCM d10[0]:0.0002097      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4848 at Sat Nov 7 18:39:52 EST 2009
    
    Left Arm Top VDC Current : -0.634766
    Left Arm Bottom VDC Current : 0.634766
    Left Arm Top VDC voltage : 3.99463
    Left Arm Bottom VDC voltage : 4
    -----
    Right Arm Top VDC Current : -27.6367
    Right Arm Bottom VDC Current : -3.07617
    Right Arm Top VDC voltage : 3.99707
    Right Arm Bottom VDC voltage : 4.01514
    -----
    Left Arm Q1 momentum : 3.66029
    Left Arm Q1 power supply : 2753.75
    Left Arm Q1 gauss meter : -0.23217
    Left Arm Q2 gauss meter : 0.8273
    Left Arm Q2 power supply current : 1575.85
    Left Arm Q2 momentum : 3.65967
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.22
    Left Arm D1 momentum : 3.66007
    Left Arm D1 NMR : 1.35577
    Left Arm arm angle : 12.8988
    Left Arm Q3 gauss meter : -0.73457
    Left Arm Q3 power supply current : 1457.2
    Left Arm Q3 momentum : 3.66021
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 2.62972
    Right Arm Q1 power supply : 1977.38
    Right Arm Q1 gauss meter : -0.04909
    Right Arm Q2 power supply current : 1132.11
    Right Arm Q2 momentum : 2.63056
    Right Arm Q2 gauss meter : 0.5924
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 932.843
    Right Arm D1 momentum : 2.62993
    Right Arm D1 NMR : 0.975934
    Right Arm arm angle : 20.001
    Right Arm Q3 power supply current : 1046.64
    Right Arm Q3 momentum : 2.63035
    Right Arm Q3 gauss meter : 0.4684
    Right Arm Q3 power supply polarity : disabled
    -----
    Average current of the two cavities : 2.07016
    Current on Unser monitor : 19.5874
    Current on Upstream bcm : 2.00862
    Current on Downstream bcm : 2.13171
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 2.22934
    Hall C Current : 0
    MBSY1c magnet current (amp) : 254.343
    MBSY1c Bdl : 1.51764e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.38
    Hall A momentum orbit correction (dpp) : -1.27198e-05
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6067.38
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 0.761379
    IPM1C12.XPOS : -0.00526935
    IPM1H04A.XPOS : -2.91712
    IPM1H04A.YPOS : 1.91329
    IPM1H04B.XPOS : -2.99713
    IPM1H04B.YPOS : 1.95217
    -----
    Wien angle : 74.7279
    Wien BDL : 1724.8
    Wien field : 49.796
    Laser attenuation Hall A : 60
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    -----
    Target : L1 20cm
    fan frequency loop 1 : 60
    fan frequency loop 3 : 0
    Encoder position : 3.30777e+07
    Target type : 3.30777e+07
    temperature loop 1(1) : 21.99
    temperature loop 1(2) : 21.94
    temperature loop 1(3) : 22.26
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.5
    Heat exchange LH2 : 273.5
    HPH H2 loop 1 : 1106.18
    HPH H2 loop 3 : 0.0244217