Privacy and Security Notice

End_of_Run_25321


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 18:48:27 on November 7, 2009

    Entry number 298169

    keyword=End_of_Run_25321
    ****************************
     Run Number: 25321
     End of Run Comment:
    Run_type=Check out,target_type=LD2, 20cm,beam_e0=6.06,beam_raster=on,beam_current=10,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=20.0,rightarm_sieve=out,comment_text=during position survey
     
    
    PRESCALE FACTORS:ps1=2   ps2=99999   ps3=99999   ps4=99999   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 1007670      
    TIME     : [0]: 8.263 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  30.25%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :2913.2/5826.4 Hz   T2[0] : 0.0/62.0 Hz   T3[0] : 0.0/0.1  Hz   T4[0] : 0.0/0.0  Hz   T5[0] : 0.5/33049.5 Hz   T6[0] : 0.4/27220.2 Hz   T7[0] : 0.2/10083.8 Hz   T8[0] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :1444356/2888713  T2[0] :      0/30760    T3[0] :      0/59       T4[0] :      0/21       T5[0] :    250/16385754  T6[0] :    205/13495626  T7[0] :     76/4999490  T8[0] :      7/507693   
    
    AVERAGE CURRENT
    BCM x1 : 1.4495 uA  BCM x3 : 0.3669 uA  BCM x10: 1.4655 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.0007162      BCM u3 [0]:0.0003722      BCM u10[0]:0.0007244      
    
    BCM d1 [0]:0.0007211      BCM d3 [0]:-8.356E-06     BCM d10[0]:0.0007287      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 25321 at Sat Nov 7 18:48:24 EST 2009
    
    Left Arm Top VDC Current : 3.90625
    Left Arm Bottom VDC Current : -2.00195
    Left Arm Top VDC voltage : 3.99707
    Left Arm Bottom VDC voltage : 4
    -----
    Right Arm Top VDC Current : -22.7539
    Right Arm Bottom VDC Current : 0.585938
    Right Arm Top VDC voltage : 3.99951
    Right Arm Bottom VDC voltage : 4.00732
    -----
    Left Arm Q1 momentum : 3.66029
    Left Arm Q1 power supply : 2753.8
    Left Arm Q1 gauss meter : -0.23218
    Left Arm Q2 gauss meter : 0.8273
    Left Arm Q2 power supply current : 1575.85
    Left Arm Q2 momentum : 3.65965
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.23
    Left Arm D1 momentum : 3.66007
    Left Arm D1 NMR : 1.35577
    Left Arm arm angle : 12.8988
    Left Arm Q3 gauss meter : -0.73457
    Left Arm Q3 power supply current : 1457.2
    Left Arm Q3 momentum : 3.66021
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 2.62972
    Right Arm Q1 power supply : 1977.38
    Right Arm Q1 gauss meter : -0.04911
    Right Arm Q2 power supply current : 1132.11
    Right Arm Q2 momentum : 2.63057
    Right Arm Q2 gauss meter : 0.5925
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 932.84
    Right Arm D1 momentum : 2.62992
    Right Arm D1 NMR : 0.975933
    Right Arm arm angle : 20.001
    Right Arm Q3 power supply current : 1046.64
    Right Arm Q3 momentum : 2.63035
    Right Arm Q3 gauss meter : 0.4684
    Right Arm Q3 power supply polarity : disabled
    -----
    Average current of the two cavities : 2.10085
    Current on Unser monitor : 19.5132
    Current on Upstream bcm : 2.04914
    Current on Downstream bcm : 2.15256
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 2.27575
    Hall C Current : 0
    MBSY1c magnet current (amp) : 254.343
    MBSY1c Bdl : 1.51764e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.37
    Hall A momentum orbit correction (dpp) : -1.40522e-05
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6067.33
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 0.761379
    IPM1C12.XPOS : 0.00811881
    IPM1H04A.XPOS : -2.89739
    IPM1H04A.YPOS : 0.315133
    IPM1H04B.XPOS : -2.96881
    IPM1H04B.YPOS : 0.07828
    -----
    Wien angle : 74.7279
    Wien BDL : 1724.8
    Wien field : 49.796
    Laser attenuation Hall A : 60
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    -----
    Target : L1 20cm
    fan frequency loop 1 : 60
    fan frequency loop 3 : 0
    Encoder position : 3.30777e+07
    Target type : 3.30777e+07
    temperature loop 1(1) : 22
    temperature loop 1(2) : 21.96
    temperature loop 1(3) : 22.28
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.5
    Heat exchange LH2 : 273.5
    HPH H2 loop 1 : 1064.45
    HPH H2 loop 3 : 0.0170928