     Run Number: 4851
     End of Run Comment:
    Run_type=Check out,target_type=LD2, 20cm,beam_e0=6.06,beam_raster=on,beam_current=110,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=20,rightarm_sieve=out,comment_text=during position survey
     
    
    PRESCALE FACTORS:ps1=20   ps2=16777215   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 16003        
    TIME     : [0]: 5.132 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  48.18%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :99.9/1998.3 Hz   T2[0] : 0.0/104.9 Hz   T3[0] : 0.0/41.7 Hz   T4[0] : 0.0/6.6  Hz   T5[0] : 0.0/29.5 Hz   T6[0] : 0.0/21.2 Hz   T7[0] : 0.4/24127.6 Hz   T8[0] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  30766/615323   T2[0] :      0/32311    T3[0] :      0/12829    T4[0] :      0/2041     T5[0] :      0/9077     T6[0] :      0/6526     T7[0] :    113/7429559  T8[0] :      4/315318   
    
    AVERAGE CURRENT
    BCM x1 : 0.7867 uA  BCM x3 : 1.6214 uA  BCM x10: 0.8626 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:-4.705E-05     BCM u3 [0]:0.001004       BCM u10[0]:-5.595E-06     
    
    BCM d1 [0]:0.0005315      BCM d3 [0]:-5.19E-06      BCM d10[0]:0.0005368      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4851 at Sat Nov 7 19:16:28 EST 2009
    
    Left Arm Top VDC Current : -0.878906
    Left Arm Bottom VDC Current : 0.292969
    Left Arm Top VDC voltage : 4
    Left Arm Bottom VDC voltage : 4.00049
    -----
    Right Arm Top VDC Current : -10.3027
    Right Arm Bottom VDC Current : -3.41797
    Right Arm Top VDC voltage : 3.99658
    Right Arm Bottom VDC voltage : 4.01367
    -----
    Left Arm Q1 momentum : 0.00103422
    Left Arm Q1 power supply : 0
    Left Arm Q1 gauss meter : 0.0002454
    Left Arm Q2 gauss meter : 0.8272
    Left Arm Q2 power supply current : 1575.85
    Left Arm Q2 momentum : 3.65966
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 5.54458
    Left Arm D1 momentum : 0.0558417
    Left Arm D1 NMR : 0.892466
    Left Arm arm angle : 12.8988
    Left Arm Q3 gauss meter : -0.73461
    Left Arm Q3 power supply current : 1457.21
    Left Arm Q3 momentum : 3.66025
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 0.00202015
    Right Arm Q1 power supply : 0.106813
    Right Arm Q1 gauss meter : -5.81e-05
    Right Arm Q2 power supply current : 1132.12
    Right Arm Q2 momentum : 2.63059
    Right Arm Q2 gauss meter : 0.5925
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 933.048
    Right Arm D1 momentum : 2.62996
    Right Arm D1 NMR : 0.975945
    Right Arm arm angle : 20.001
    Right Arm Q3 power supply current : -0.00219695
    Right Arm Q3 momentum : -5.52123e-06
    Right Arm Q3 gauss meter : 7.8e-05
    Right Arm Q3 power supply polarity : disabled
    -----
    Average current of the two cavities : 0.0316773
    Current on Unser monitor : 17.5638
    Current on Upstream bcm : 0.0387847
    Current on Downstream bcm : 0.0245698
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 0.147443
    Hall C Current : 0
    MBSY1c magnet current (amp) : 254.343
    MBSY1c Bdl : 1.51764e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.46
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6067.46
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 0.761379
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Wien angle : 74.7279
    Wien BDL : 1724.8
    Wien field : 49.796
    Laser attenuation Hall A : 60
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    -----
    Target : L1 20cm
    fan frequency loop 1 : 59.5
    fan frequency loop 3 : 0
    Encoder position : 3.30777e+07
    Target type : 3.30777e+07
    temperature loop 1(1) : 21.93
    temperature loop 1(2) : 21.88
    temperature loop 1(3) : 22.19
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.4
    Heat exchange LH2 : 273.4
    HPH H2 loop 1 : 1086.95
    HPH H2 loop 3 : 0.00293052