Privacy and Security Notice

Start_Run_25327,Run_type=Cosmics,target_type=Optics,targetpol_poldir=Longitudinal,targetpol_pol=87,beam_e0=6.0,beam_raster=on,beam_current=5.0,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=19.0,rightarm_sieve=out,comment_text=


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 23:27:14 on November 7, 2009

    Entry number 298198

    keyword=Start_Run_25327,Run_type=Cosmics,target_type=Optics,targetpol_poldir=Longitudinal,targetpol_pol=87,beam_e0=6.0,beam_raster=on,beam_current=5.0,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=19.0,rightarm_sieve=out,comment_text=
    Run Timestamp:       Sat Nov  7 23:26:52 EST 2009
    Beginning-of-run EPICS data for Run Number 25327 at Sat Nov 7 23:27:02 EST 2009
    
    
    
    Run_type=Cosmics
    target_type=Optics
    targetpol_poldir=Longitudinal
    targetpol_pol=87
    beam_e0=6.0
    beam_raster=on
    beam_current=5.0
    leftarm_p=3.66
    leftarm_theta=12.9
    leftarm_sieve=out
    rightarm_p=2.63
    rightarm_theta=19.0
    rightarm_sieve=out
    comment_text=
    
    
    ; L-HRS DAQ on adaql3/a-onl account
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Change this file only in-between runs.
    ; Maxima: (2^24)-1 = 16777215 for T1-T4 and 65535 for T5-T8
    ; The default factor is essentially infinite.
    ; T1 = L-HRS HAPPEX Trigger
    ; T2 = L-HRS S0 trigger (of most importance)
    ; T3-T7 = Eventually PVDIS stuff
    ; T8 = 1024 Hz pulser
    ; String should be one line, no spaces, ending in carriage return
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    
     ps1=1,ps2=99999,ps3=99999,ps4=99999,ps5=65535,ps6=65535,ps7=65535,ps8=65535
    
    
    
    Left Arm Q1 momentum : 3.66043
    Left Arm Q1 power supply : 2753.8
    Left Arm Q1 gauss meter : -0.23215
    Left Arm Q2 power supply current : 1575.84
    Left Arm Q2 momentum : 3.65963
    Left Arm Q2 gauss meter : 0.8272
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.23
    Left Arm D1 momentum : 3.6601
    Left Arm D1 NMR : 1.35578
    Left Arm Q3 power supply current : 1457.19
    Left Arm Q3 momentum : 3.6602
    Left Arm Q3 gauss meter : -0.73457
    Left Arm Q3 power supply polarity : disabled
    Left Arm B Field Hall Probe (D-G) : -1.306
    -----
    Right Arm Q1 momentum : 2.62965
    Right Arm Q1 power supply : 1977.33
    Right Arm Q1 gauss meter : -0.0491
    Right Arm Q2 power supply current : 1132.11
    Right Arm Q2 momentum : 2.63056
    Right Arm Q2 gauss meter : 0.5924
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 932.855
    Right Arm D1 momentum : 2.63004
    Right Arm D1 NMR : 0.975977
    Right Arm Q3 power supply current : 1046.68
    Right Arm Q3 momentum : 2.63044
    Right Arm Q3 gauss meter : 0.4683
    Right Arm Q3 power supply polarity : disabled
    Right Arm B Field Hall Probe (D-G) : -0.9643
    -----
    Left Arm Top VDC Current : 0.927734
    Left Arm Bottom VDC Current : -1.41602
    Left Arm Top VDC voltage : 3.99902
    Left Arm Bottom VDC voltage : 4
    -----
    Right Arm Top VDC Current : -22.0215
    Right Arm Bottom VDC Current : -2.68555
    Right Arm Top VDC voltage : 4.00098
    Right Arm Bottom VDC voltage : 4.00781
    -----
    Average current of the two cavities : 5.26779
    Current on Unser monitor : 22.8671
    Current on Upstream bcm : 5.12383
    Current on Downstream bcm : 5.41176
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 5.47237
    Hall C Current : 0
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.36
    Hall A momentum orbit correction (dpp) : -1.65363e-05
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6067.36
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 0.761379
    MBSY1c magnet current (amp) : 254.343
    MBSY1c Bdl : 1.51764e+06
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    Raster X width : 6
    Raster Y width : 6
    -----
    HacL_HPE1313A:0_Ch58 : -0.240723
    HacL_HPE1313A:0_Ch55 : 23.291
    HacL_HPE1313A:0_Ch54 : 0.0737305
    Left Arm Angle Floor Angle : 13
    Left Arm Angle Vernier : 13.5
    Left Arm Scattering Angle : 12.8988
    -----
    Right Arm D1 momentum : 2.63004
    Right Arm arm angle : 20.001
    -----
    Left VDC -DISC LVL Top : 3.88525
    Left VDC -DISC LVL Bottom : 3.9668
    Left VDC -DISC LVL Voltage1 : 4.97705
    Left VDC -DISC LVL Voltage2 : -5.06738
    -----
    Right Arm Arm Collimator : 0.0262207
    HacR_HPE1313A:0_Ch58 : -0.588379
    HacR_HPE1313A:0_Ch55 : 22.3145
    HacR_HPE1313A:0_Ch54 : -0.910156
    Right Arm Angle Floor Angle : 20
    Right Arm Angle Vernier : -34
    Right Arm Scattering Angle : 20.001
    -----
    IPM1C12.XPOS : 0.0129905
    IPM1C12.YPOS : 0.171916
    IPM1H04A.XPOS : -2.94262
    IPM1H04A.YPOS : -1.25341
    IPM1H04B.XPOS : -2.99957
    IPM1H04B.YPOS : -1.55242
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    -----
    Wien angle : 74.7279
    Wien BDL : 1724.8
    Wien field : 49.796
    Laser attenuation Hall A : 68
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Delay Set : 8 cycles
    Helicity Pattern Set : Quartet
    Helicity Clock Set : Free Clock
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    Helicity Clock Read : Free Clock
    Helicity Frequency : 29.5596
    -----
    Target : Optics
    fan frequency loop 1 : 60
    fan frequency loop 2 : 0
    fan frequency loop 3 : 0
    Encoder position : 1.26745e+07
    Target type : 1.26745e+07
    temperature loop 1(1) : 22
    temperature loop 1(2) : 21.95
    temperature loop 1(3) : 22.27
    Heat exchange loop 1 H2 : 24.5
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange loop 3 H2 : 273.3
    pressure loop He : 48.3735
    pressure loop H2 before : 25.4185
    pressure loop H2 return : 24.5594
    HPH He loop 1 : 1095.67
    HPH He loop 2 : 0.0125677
    HPH H2 loop 3 : 0.00540827
    
    Left S2 HV Left PMTs
    S2 Slot0 ch0 Left : -1640.5
    S2 Slot0 ch1 Left : -1690.8
    S2 Slot0 ch2 Left : -2015.9
    S2 Slot0 ch3 Left : -1820.2
    S2 Slot0 ch4 Left : -1858.4
    S2 Slot0 ch5 Left : -1661.7
    S2 Slot0 ch6 Left : -1837.5
    S2 Slot0 ch7 Left : -1803.6
    S2 Slot0 ch8 Left : -1796.6
    S2 Slot0 ch9 Left : -1918.4
    S2 Slot0 ch10 Left : -1976.3
    S2 Slot0 ch11 Left : -1822.9
    S2 Slot13 ch0 Left : -1954.5
    S2 Slot13 ch1 Left : -2006.7
    S2 Slot13 ch2 Left : -1776.6
    S2 Slot13 ch3 Left : -1559.8
    -----
    Left S2 HV Right PMTs
    S2 Slot12 ch0 Right : -1484.3
    S2 Slot12 ch1 Right : -1627.6
    S2 Slot12 ch2 Right : -1780.8
    S2 Slot12 ch3 Right : -1699.9
    S2 Slot12 ch4 Right : -1758
    S2 Slot12 ch5 Right : -1731.7
    S2 Slot12 ch6 Right : -1765.1
    S2 Slot12 ch7 Right : -1472.1
    S2 Slot12 ch8 Right : -1825.3
    S2 Slot12 ch9 Right : -1700
    S2 Slot12 ch10 Right : -1829.3
    S2 Slot12 ch11 Right : -1550.9
    S2 Slot13 ch4 Right : -1553
    S2 Slot13 ch5 Right : -1635.9
    S2 Slot13 ch6 Right : -1650
    S2 Slot13 ch7 Right : -1626.6
    -----
    Left S1 HV
    S1 Slot1 ch0 : -1660.9
    S1 Slot1 ch1 : -1785.3
    S1 Slot1 ch2 : -1621.1
    S1 Slot1 ch3 : -1676.5
    S1 Slot1 ch4 : -1657.1
    S1 Slot1 ch5 : -1870.7
    S1 Slot1 ch6 : -1836.6
    S1 Slot1 ch7 : -1675.6
    S1 Slot1 ch8 : -1556.9
    S1 Slot1 ch9 : -1621.1
    S1 Slot1 ch10 : -1746.5
    S1 Slot1 ch11 : -1760.6
    -----
    Left Cerenkov HV
    GCER Slot2 ch0 : -1522.3
    GCER Slot2 ch1 : -1436.5
    GCER Slot2 ch2 : -1511.2
    GCER Slot2 ch3 : -1421.2
    GCER Slot2 ch4 : -1766.4
    GCER Slot2 ch5 : -1990.5
    GCER Slot2 ch6 : -15.5
    GCER Slot2 ch7 : -1724.8
    GCER Slot2 ch8 : -1960.8
    GCER Slot2 ch9 : -1520.5
    GCER Slot2 ch10 : -1745.2
    GCER Slot2 ch11 : -14.6
    -----
    Left Pion Rejector Layer 1 HV
    PRL1 Slot3 ch0 : -900.3
    PRL1 Slot3 ch1 : -815.1
    PRL1 Slot3 ch2 : -931.9
    PRL1 Slot3 ch3 : -986.6
    PRL1 Slot3 ch4 : -787.1
    PRL1 Slot3 ch5 : -886.9
    PRL1 Slot3 ch6 : -1095
    PRL1 Slot3 ch7 : -1012.6
    PRL1 Slot3 ch8 : -834.9
    PRL1 Slot3 ch9 : -816.1
    PRL1 Slot3 ch10 : -886.6
    PRL1 Slot3 ch11 : -809.5
    PRL1 Slot4 ch0 : -901.1
    PRL1 Slot4 ch1 : -931.4
    PRL1 Slot4 ch2 : -768.2
    PRL1 Slot4 ch3 : -942
    PRL1 Slot4 ch4 : -921.7
    PRL1 Slot4 ch5 : -901.3
    PRL1 Slot4 ch6 : -920.2
    PRL1 Slot4 ch7 : -796.5
    PRL1 Slot4 ch8 : -884
    PRL1 Slot4 ch9 : -810.7
    PRL1 Slot4 ch10 : -911.3
    PRL1 Slot4 ch11 : -851.5
    PRL1 Slot5 ch0 : -885.9
    PRL1 Slot5 ch1 : -829.7
    PRL1 Slot5 ch2 : -778.7
    PRL1 Slot5 ch3 : -836.2
    PRL1 Slot5 ch4 : -840.9
    PRL1 Slot5 ch5 : -755.2
    PRL1 Slot5 ch6 : -800.4
    PRL1 Slot5 ch7 : -860.3
    PRL1 Slot5 ch8 : -881.3
    PRL1 Slot5 ch9 : -968.3
    PRL1 Slot5 ch10 : -5
    PRL1 Slot5 ch11 : -14.9
    -----
    Left Pion Rejector Layer 2 HV
    PRL2 Slot9 ch0 : -804.7
    PRL2 Slot9 ch1 : -796.3
    PRL2 Slot9 ch2 : -820.8
    PRL2 Slot9 ch3 : -772.6
    PRL2 Slot9 ch4 : -720.6
    PRL2 Slot9 ch5 : -901
    PRL2 Slot9 ch6 : -795.8
    PRL2 Slot9 ch7 : -990.2
    PRL2 Slot9 ch8 : -924.2
    PRL2 Slot9 ch9 : -865.2
    PRL2 Slot9 ch10 : -1080.7
    PRL2 Slot9 ch11 : -1054.4
    PRL2 Slot10 ch0 : -806.2
    PRL2 Slot10 ch1 : -861.3
    PRL2 Slot10 ch2 : -1009.7
    PRL2 Slot10 ch3 : -904.5
    PRL2 Slot10 ch4 : -864.8
    PRL2 Slot10 ch5 : -825.6
    PRL2 Slot10 ch6 : -838.1
    PRL2 Slot10 ch7 : -829.4
    PRL2 Slot10 ch8 : -1190.4
    PRL2 Slot10 ch9 : -1041.2
    PRL2 Slot10 ch10 : -1081.1
    PRL2 Slot10 ch11 : -836.5
    PRL2 Slot11 ch0 : -1075.5
    PRL2 Slot11 ch1 : -900.4
    PRL2 Slot11 ch2 : -946.3
    PRL2 Slot11 ch3 : -765.8
    PRL2 Slot11 ch4 : -914.8
    PRL2 Slot11 ch5 : -823.8
    PRL2 Slot11 ch6 : -839
    PRL2 Slot11 ch7 : -890.5
    PRL2 Slot11 ch8 : -785.9
    PRL2 Slot11 ch9 : -840.6
    PRL2 Slot11 ch10 : -2.9
    PRL2 Slot11 ch11 : -11.7
    -----
    # Map  RHRS_VDC  Measured Voltage
       XXX 
    # Map  RHRS_VDC  Measured Current
       XXX 
    # Map  RHRS_PMTS  Measured Voltage
      1 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
      2 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
      3 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
      4 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
      5 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
      6 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
      7 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
      8 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
      9 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
     10 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
     11 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
     12 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
    # Map  RHRS_PMTS  Measured Current
      1 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
      2 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
      3 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
      4 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
      5 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
      6 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
      7 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
      8 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
      9 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
     10 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
     11 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
     12 :    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX    XXX 
    CODA config : config RightHrs LeftHrs
    HAPPEX run : 13788