Privacy and Security Notice

End_of_Run_4853


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 23:35:00 on November 7, 2009

    Entry number 298202

    keyword=End_of_Run_4853
    ****************************
     Run Number: 4853
     End of Run Comment:
    Run_type=Cosmics,target_type=Optics,beam_e0=6.06,beam_raster=on,beam_current=5,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=20,rightarm_sieve=out,comment_text=optics target, doing beam position scan 
    
    PRESCALE FACTORS:ps1=1   ps2=16777215   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 500365       
    TIME     : [0]: 24.468 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:   6.38%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :363.9/363.9 Hz   T2[0] : 0.0/26.8 Hz   T3[0] : 0.0/13.8 Hz   T4[0] : 0.0/0.7  Hz   T5[0] : 0.0/17.1 Hz   T6[0] : 0.0/18.3 Hz   T7[0] : 0.2/13825.0 Hz   T8[0] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 534210/534210   T2[0] :      0/39285    T3[0] :      0/20278    T4[0] :      0/984      T5[0] :      0/25143    T6[0] :      0/26886    T7[0] :    309/20296253  T8[0] :     22/1503313  
    
    AVERAGE CURRENT
    BCM x1 : 2.1262 uA  BCM x3 : 0.9152 uA  BCM x10: 2.2168 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:-0.0002243     BCM u3 [0]:0.002712       BCM u10[0]:-2.853E-05     
    
    BCM d1 [0]:0.006467       BCM d3 [0]:-2.474E-05     BCM d10[0]:0.006537       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4853 at Sat Nov 7 23:34:56 EST 2009
    
    Left Arm Top VDC Current : 1.07422
    Left Arm Bottom VDC Current : 0
    Left Arm Top VDC voltage : 4.00195
    Left Arm Bottom VDC voltage : 4.00098
    -----
    Right Arm Top VDC Current : 10.6934
    Right Arm Bottom VDC Current : 0.341797
    Right Arm Top VDC voltage : 3.99609
    Right Arm Bottom VDC voltage : 4.00391
    -----
    Left Arm Q1 momentum : 3.66043
    Left Arm Q1 power supply : 2753.86
    Left Arm Q1 gauss meter : -0.23216
    Left Arm Q2 gauss meter : 0.8272
    Left Arm Q2 power supply current : 1575.84
    Left Arm Q2 momentum : 3.65964
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.23
    Left Arm D1 momentum : 3.6601
    Left Arm D1 NMR : 1.35578
    Left Arm arm angle : 12.8988
    Left Arm Q3 gauss meter : -0.73457
    Left Arm Q3 power supply current : 1457.19
    Left Arm Q3 momentum : 3.6602
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 2.62972
    Right Arm Q1 power supply : 1977.38
    Right Arm Q1 gauss meter : -0.04911
    Right Arm Q2 power supply current : 1132.11
    Right Arm Q2 momentum : 2.63056
    Right Arm Q2 gauss meter : 0.5925
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 932.855
    Right Arm D1 momentum : 2.63003
    Right Arm D1 NMR : 0.975974
    Right Arm arm angle : 20.001
    Right Arm Q3 power supply current : 1046.68
    Right Arm Q3 momentum : 2.63045
    Right Arm Q3 gauss meter : 0.4683
    Right Arm Q3 power supply polarity : disabled
    -----
    Average current of the two cavities : 5.15953
    Current on Unser monitor : 23.0494
    Current on Upstream bcm : 5.02107
    Current on Downstream bcm : 5.29799
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 5.3478
    Hall C Current : 0
    MBSY1c magnet current (amp) : 254.343
    MBSY1c Bdl : 1.51764e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.39
    Hall A momentum orbit correction (dpp) : -1.15343e-05
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6067.39
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 0.761379
    IPM1C12.XPOS : 0.00161934
    IPM1H04A.XPOS : -2.96629
    IPM1H04A.YPOS : -2.06836
    IPM1H04B.XPOS : -3.00692
    IPM1H04B.YPOS : -2.00936
    -----
    Wien angle : 74.7279
    Wien BDL : 1724.8
    Wien field : 49.796
    Laser attenuation Hall A : 68
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    -----
    Target : Optics
    fan frequency loop 1 : 60
    fan frequency loop 3 : 0
    Encoder position : 1.26745e+07
    Target type : 1.26745e+07
    temperature loop 1(1) : 22
    temperature loop 1(2) : 21.96
    temperature loop 1(3) : 22.27
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.5
    Heat exchange LH2 : 273.4
    HPH H2 loop 1 : 1059.29
    HPH H2 loop 3 : 0.000504939