Privacy and Security Notice

End_of_Run_25328


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 23:36:05 on November 7, 2009

    Entry number 298203

    keyword=End_of_Run_25328
    ****************************
     Run Number: 25328
     End of Run Comment:
    Run_type=Check out,target_type=Optics,beam_e0=6.06,beam_raster=on,beam_current=5,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=20.0,rightarm_sieve=out,comment_text=special run with BPM Y =-2mm
     
    
    PRESCALE FACTORS:ps1=1   ps2=99999   ps3=99999   ps4=99999   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 1004275      
    TIME     : [0]: 7.630 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  35.05%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :3377.5/3377.5 Hz   T2[0] : 0.0/44.7 Hz   T3[0] : 0.0/0.1  Hz   T4[0] : 0.0/0.0  Hz   T5[0] : 0.0/16.7 Hz   T6[0] : 0.0/645.8 Hz   T7[0] : 0.1/8784.6 Hz   T8[0] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :1546230/1546230  T2[0] :      0/20448    T3[0] :      0/33       T4[0] :      0/13       T5[0] :      0/7665     T6[0] :      4/295652   T7[0] :     61/4021621  T8[0] :      7/468790   
    
    AVERAGE CURRENT
    BCM x1 : 5.0815 uA  BCM x3 : 0.1991 uA  BCM x10: 5.1332 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.002317       BCM u3 [0]:0.00019        BCM u10[0]:0.002339       
    
    BCM d1 [0]:0.002336       BCM d3 [0]:-7.716E-06     BCM d10[0]:0.002361       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 25328 at Sat Nov 7 23:36:01 EST 2009
    
    Left Arm Top VDC Current : 4.05273
    Left Arm Bottom VDC Current : -0.927734
    Left Arm Top VDC voltage : 4.00195
    Left Arm Bottom VDC voltage : 4
    -----
    Right Arm Top VDC Current : -27.4902
    Right Arm Bottom VDC Current : -3.51562
    Right Arm Top VDC voltage : 3.99707
    Right Arm Bottom VDC voltage : 4.01611
    -----
    Left Arm Q1 momentum : 3.66043
    Left Arm Q1 power supply : 2753.86
    Left Arm Q1 gauss meter : -0.23218
    Left Arm Q2 gauss meter : 0.8273
    Left Arm Q2 power supply current : 1575.84
    Left Arm Q2 momentum : 3.65965
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.23
    Left Arm D1 momentum : 3.6601
    Left Arm D1 NMR : 1.35578
    Left Arm arm angle : 12.8988
    Left Arm Q3 gauss meter : -0.7346
    Left Arm Q3 power supply current : 1457.19
    Left Arm Q3 momentum : 3.6602
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 2.62972
    Right Arm Q1 power supply : 1977.38
    Right Arm Q1 gauss meter : -0.04909
    Right Arm Q2 power supply current : 1132.11
    Right Arm Q2 momentum : 2.63056
    Right Arm Q2 gauss meter : 0.5925
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 932.855
    Right Arm D1 momentum : 2.63003
    Right Arm D1 NMR : 0.975974
    Right Arm arm angle : 20.001
    Right Arm Q3 power supply current : 1046.68
    Right Arm Q3 momentum : 2.63045
    Right Arm Q3 gauss meter : 0.4683
    Right Arm Q3 power supply polarity : disabled
    -----
    Average current of the two cavities : 5.15277
    Current on Unser monitor : 23.4065
    Current on Upstream bcm : 5.01712
    Current on Downstream bcm : 5.28843
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 5.35212
    Hall C Current : 0
    MBSY1c magnet current (amp) : 254.343
    MBSY1c Bdl : 1.51764e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.39
    Hall A momentum orbit correction (dpp) : -9.90287e-06
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6067.4
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 0.761379
    IPM1C12.XPOS : -0.00474393
    IPM1H04A.XPOS : -2.96136
    IPM1H04A.YPOS : -2.07735
    IPM1H04B.XPOS : -3.01093
    IPM1H04B.YPOS : -2.01616
    -----
    Wien angle : 74.7279
    Wien BDL : 1724.8
    Wien field : 49.796
    Laser attenuation Hall A : 68
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    -----
    Target : Optics
    fan frequency loop 1 : 60
    fan frequency loop 3 : 0
    Encoder position : 1.26745e+07
    Target type : 1.26745e+07
    temperature loop 1(1) : 21.98
    temperature loop 1(2) : 21.94
    temperature loop 1(3) : 22.25
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.5
    Heat exchange LH2 : 273.4
    HPH H2 loop 1 : 1125.58
    HPH H2 loop 3 : 0.00293052