Privacy and Security Notice

End_of_Run_4855


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 23:54:59 on November 7, 2009

    Entry number 298211

    keyword=End_of_Run_4855
    ****************************
     Run Number: 4855
     End of Run Comment:
    Run_type=Optics,target_type=Optics,beam_e0=6.06,beam_raster=on,beam_current=110,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=20,rightarm_sieve=out,comment_text=Optics : Raster on, sieve out
     
    
    PRESCALE FACTORS:ps1=1   ps2=16777215   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 25102        
    TIME     : [0]: 1.241 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  15.75%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :399.8/399.8 Hz   T2[0] : 0.0/31.7 Hz   T3[0] : 0.0/17.0 Hz   T4[0] : 0.0/0.7  Hz   T5[0] : 0.0/20.4 Hz   T6[0] : 0.0/22.3 Hz   T7[0] : 0.2/15588.2 Hz   T8[0] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  29777/29777    T2[0] :      0/2360     T3[0] :      0/1265     T4[0] :      0/49       T5[0] :      0/1516     T6[0] :      0/1662     T7[0] :     17/1161120  T8[0] :      1/76275    
    
    AVERAGE CURRENT
    BCM x1 : 4.7644 uA  BCM x3 : 1.0361 uA  BCM x10: 4.8839 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:-1.138E-05     BCM u3 [0]:0.0001556      BCM u10[0]:-1.437E-06     
    
    BCM d1 [0]:0.0007212      BCM d3 [0]:-1.255E-06     BCM d10[0]:0.000729       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4855 at Sat Nov 7 23:54:55 EST 2009
    
    Left Arm Top VDC Current : 5.32227
    Left Arm Bottom VDC Current : 1.46484
    Left Arm Top VDC voltage : 4.00342
    Left Arm Bottom VDC voltage : 4
    -----
    Right Arm Top VDC Current : -3.07617
    Right Arm Bottom VDC Current : 1.31836
    Right Arm Top VDC voltage : 3.99805
    Right Arm Bottom VDC voltage : 3.99658
    -----
    Left Arm Q1 momentum : 3.66043
    Left Arm Q1 power supply : 2753.86
    Left Arm Q1 gauss meter : -0.23218
    Left Arm Q2 gauss meter : 0.8272
    Left Arm Q2 power supply current : 1575.85
    Left Arm Q2 momentum : 3.65966
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.24
    Left Arm D1 momentum : 3.6601
    Left Arm D1 NMR : 1.35578
    Left Arm arm angle : 12.8988
    Left Arm Q3 gauss meter : -0.73461
    Left Arm Q3 power supply current : 1457.2
    Left Arm Q3 momentum : 3.66022
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 2.62972
    Right Arm Q1 power supply : 1977.38
    Right Arm Q1 gauss meter : -0.04909
    Right Arm Q2 power supply current : 1132.11
    Right Arm Q2 momentum : 2.63057
    Right Arm Q2 gauss meter : 0.5925
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 932.856
    Right Arm D1 momentum : 2.63002
    Right Arm D1 NMR : 0.975968
    Right Arm arm angle : 20.001
    Right Arm Q3 power supply current : 1046.68
    Right Arm Q3 momentum : 2.63045
    Right Arm Q3 gauss meter : 0.4683
    Right Arm Q3 power supply polarity : disabled
    -----
    Average current of the two cavities : 9.88149
    Current on Unser monitor : 27.1929
    Current on Upstream bcm : 9.61493
    Current on Downstream bcm : 10.1481
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 10.0618
    Hall C Current : 0
    MBSY1c magnet current (amp) : 254.343
    MBSY1c Bdl : 1.51764e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.38
    Hall A momentum orbit correction (dpp) : -1.30809e-05
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6067.38
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 0.761379
    IPM1C12.XPOS : 0.0100468
    IPM1H04A.XPOS : -2.89783
    IPM1H04A.YPOS : 2.18252
    IPM1H04B.XPOS : -2.98523
    IPM1H04B.YPOS : 2.02003
    -----
    Wien angle : 74.7279
    Wien BDL : 1724.8
    Wien field : 49.796
    Laser attenuation Hall A : 74
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    -----
    Target : Optics
    fan frequency loop 1 : 59.5
    fan frequency loop 3 : 0
    Encoder position : 1.26745e+07
    Target type : 1.26745e+07
    temperature loop 1(1) : 22
    temperature loop 1(2) : 21.97
    temperature loop 1(3) : 22.28
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.5
    Heat exchange LH2 : 273.4
    HPH H2 loop 1 : 1086.95
    HPH H2 loop 3 : 0.011068