Privacy and Security Notice

End_of_Run_25333


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 00:56:21 on November 8, 2009

    Entry number 298233

    keyword=End_of_Run_25333
    ****************************
     Run Number: 25333
     End of Run Comment:
    Run_type=Optics,target_type=Holey C12,beam_e0=6.06,beam_raster=off,beam_current=10,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=20.0,rightarm_sieve=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=1   ps2=99999   ps3=99999   ps4=99999   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 1012296      
    TIME     : [0]: 15.368 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  27.15%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :1507.0/1507.0 Hz   T2[0] : 0.0/37.7 Hz   T3[0] : 0.0/0.0  Hz   T4[0] : 0.0/0.0  Hz   T5[0] : 0.0/106.1 Hz   T6[0] : 0.0/380.9 Hz   T7[0] : 0.1/7687.3 Hz   T8[0] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :1389519/1389519  T2[0] :      0/34777    T3[0] :      0/35       T4[0] :      0/21       T5[0] :      1/97850    T6[0] :      5/351224   T7[0] :    108/7088100  T8[0] :     14/944187   
    
    AVERAGE CURRENT
    BCM x1 : 61.7025uA  BCM x3 : 0.0709 uA  BCM x10: 38.2919uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.0565         BCM u3 [0]:0.0001462      BCM u10[0]:0.03647        
    
    BCM d1 [0]:0.05728        BCM d3 [0]:-1.554E-05     BCM d10[0]:0.03414        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 25333 at Sun Nov 8 00:56:17 EST 2009
    
    Left Arm Top VDC Current : -2.24609
    Left Arm Bottom VDC Current : 4.54102
    Left Arm Top VDC voltage : 4.00098
    Left Arm Bottom VDC voltage : 4.00049
    -----
    Right Arm Top VDC Current : -23.291
    Right Arm Bottom VDC Current : -1.02539
    Right Arm Top VDC voltage : 4
    Right Arm Bottom VDC voltage : 4.00781
    -----
    Left Arm Q1 momentum : 3.66029
    Left Arm Q1 power supply : 2753.8
    Left Arm Q1 gauss meter : -0.23215
    Left Arm Q2 gauss meter : 0.8272
    Left Arm Q2 power supply current : 1575.85
    Left Arm Q2 momentum : 3.65965
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.23
    Left Arm D1 momentum : 3.6601
    Left Arm D1 NMR : 1.35578
    Left Arm arm angle : 12.8988
    Left Arm Q3 gauss meter : -0.73459
    Left Arm Q3 power supply current : 1457.2
    Left Arm Q3 momentum : 3.6602
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 2.62965
    Right Arm Q1 power supply : 1977.33
    Right Arm Q1 gauss meter : -0.0491
    Right Arm Q2 power supply current : 1132.11
    Right Arm Q2 momentum : 2.63056
    Right Arm Q2 gauss meter : 0.5924
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 932.856
    Right Arm D1 momentum : 2.63003
    Right Arm D1 NMR : 0.975973
    Right Arm arm angle : 20.001
    Right Arm Q3 power supply current : 1046.68
    Right Arm Q3 momentum : 2.63045
    Right Arm Q3 gauss meter : 0.4683
    Right Arm Q3 power supply polarity : disabled
    -----
    Average current of the two cavities : 100.023
    Current on Unser monitor : 116.573
    Current on Upstream bcm : 97.4928
    Current on Downstream bcm : 102.554
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 100.547
    Hall C Current : 0
    MBSY1c magnet current (amp) : 254.343
    MBSY1c Bdl : 1.51764e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.4
    Hall A momentum orbit correction (dpp) : -1.04511e-05
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6067.4
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 0.761379
    IPM1C12.XPOS : 0.00608301
    IPM1H04A.XPOS : -2.87474
    IPM1H04A.YPOS : 1.96138
    IPM1H04B.XPOS : -2.99229
    IPM1H04B.YPOS : 2.00851
    -----
    Wien angle : 74.7279
    Wien BDL : 1724.8
    Wien field : 49.796
    Laser attenuation Hall A : 127
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    -----
    Target : Carbon Hole
    fan frequency loop 1 : 59.5
    fan frequency loop 3 : 0
    Encoder position : 9.05468e+06
    Target type : 9.05468e+06
    temperature loop 1(1) : 22
    temperature loop 1(2) : 21.96
    temperature loop 1(3) : 22.28
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.5
    Heat exchange LH2 : 273.4
    HPH H2 loop 1 : 1074.81
    HPH H2 loop 3 : 0.000817917