Privacy and Security Notice

End_of_Run_25334


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 01:06:45 on November 8, 2009

    Entry number 298238

    keyword=End_of_Run_25334
    ****************************
     Run Number: 25334
     End of Run Comment:
    Run_type=Optics,target_type=Optics,beam_e0=6.06,beam_raster=off,beam_current=10/15,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=20.0,rightarm_sieve=out,comment_text=
     
    magnet down, right arm Q3
    
    PRESCALE FACTORS:ps1=2   ps2=99999   ps3=99999   ps4=99999   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 278720       
    TIME     : [0]: 3.955 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:   8.41%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :1282.4/2564.8 Hz   T2[0] : 0.0/35.8 Hz   T3[0] : 0.0/0.1  Hz   T4[0] : 0.0/0.0  Hz   T5[0] : 0.0/114.8 Hz   T6[0] : 0.0/614.2 Hz   T7[0] : 0.1/7908.8 Hz   T8[0] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 304279/608559   T2[0] :      0/8497     T3[0] :      0/23       T4[0] :      0/8        T5[0] :      0/27233    T6[0] :      2/145724   T7[0] :     28/1876559  T8[0] :      3/242970   
    
    AVERAGE CURRENT
    BCM x1 : 14.9192uA  BCM x3 : 0.1434 uA  BCM x10: 15.0636uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.003516       BCM u3 [0]:7.204E-05      BCM u10[0]:0.003548       
    
    BCM d1 [0]:0.003564       BCM d3 [0]:-3.999E-06     BCM d10[0]:0.0036         
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 25334 at Sun Nov 8 01:06:42 EST 2009
    
    Left Arm Top VDC Current : 3.51562
    Left Arm Bottom VDC Current : -1.46484
    Left Arm Top VDC voltage : 3.99902
    Left Arm Bottom VDC voltage : 4
    -----
    Right Arm Top VDC Current : 13.916
    Right Arm Bottom VDC Current : -3.41797
    Right Arm Top VDC voltage : 3.99707
    Right Arm Bottom VDC voltage : 4.00342
    -----
    Left Arm Q1 momentum : 3.66036
    Left Arm Q1 power supply : 2753.8
    Left Arm Q1 gauss meter : -0.23215
    Left Arm Q2 gauss meter : 0.8272
    Left Arm Q2 power supply current : 1575.85
    Left Arm Q2 momentum : 3.65966
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.23
    Left Arm D1 momentum : 3.6601
    Left Arm D1 NMR : 1.35578
    Left Arm arm angle : 12.8988
    Left Arm Q3 gauss meter : -0.73459
    Left Arm Q3 power supply current : 1457.2
    Left Arm Q3 momentum : 3.66023
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 2.62965
    Right Arm Q1 power supply : 1977.33
    Right Arm Q1 gauss meter : -0.04911
    Right Arm Q2 power supply current : 1132.11
    Right Arm Q2 momentum : 2.63057
    Right Arm Q2 gauss meter : 0.5924
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 932.856
    Right Arm D1 momentum : 2.63003
    Right Arm D1 NMR : 0.97597
    Right Arm arm angle : 20.001
    Right Arm Q3 power supply current : 487.819
    Right Arm Q3 momentum : 1.22596
    Right Arm Q3 gauss meter : 0.2279
    Right Arm Q3 power supply polarity : disabled
    -----
    Average current of the two cavities : 15.3575
    Current on Unser monitor : 33.2001
    Current on Upstream bcm : 14.9282
    Current on Downstream bcm : 15.7867
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 15.4372
    Hall C Current : 0
    MBSY1c magnet current (amp) : 254.343
    MBSY1c Bdl : 1.51764e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.4
    Hall A momentum orbit correction (dpp) : -9.21422e-06
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6067.4
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 0.761379
    IPM1C12.XPOS : -0.00396344
    IPM1H04A.XPOS : -2.88634
    IPM1H04A.YPOS : 1.9445
    IPM1H04B.XPOS : -3.00469
    IPM1H04B.YPOS : 2.00588
    -----
    Wien angle : 74.7279
    Wien BDL : 1724.8
    Wien field : 49.796
    Laser attenuation Hall A : 80
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    -----
    Target : Optics
    fan frequency loop 1 : 59.5
    fan frequency loop 3 : 0
    Encoder position : 1.26745e+07
    Target type : 1.26745e+07
    temperature loop 1(1) : 22.01
    temperature loop 1(2) : 21.96
    temperature loop 1(3) : 22.27
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.5
    Heat exchange LH2 : 273.4
    HPH H2 loop 1 : 1057.57
    HPH H2 loop 3 : 0.011068