Privacy and Security Notice

End_of_Run_4859


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 01:06:55 on November 8, 2009

    Entry number 298239

    keyword=End_of_Run_4859
    ****************************
     Run Number: 4859
     End of Run Comment:
    Run_type=Optics,target_type=Holey C12,beam_e0=6.06,beam_raster=off,beam_current=10,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=20,rightarm_sieve=out,comment_text=
     
    magnet down, right arm Q3
    
    PRESCALE FACTORS:ps1=1   ps2=16777215   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 85172        
    TIME     : [0]: 4.268 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:   8.14%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :361.8/361.8 Hz   T2[0] : 0.0/32.9 Hz   T3[0] : 0.0/17.6 Hz   T4[0] : 0.0/0.8  Hz   T5[0] : 0.0/19.7 Hz   T6[0] : 0.0/22.4 Hz   T7[0] : 0.2/16563.6 Hz   T8[0] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  92656/92656    T2[0] :      0/8429     T3[0] :      0/4507     T4[0] :      0/208      T5[0] :      0/5044     T6[0] :      0/5737     T7[0] :     64/4241367  T8[0] :      4/262211   
    
    AVERAGE CURRENT
    BCM x1 : 7.2325 uA  BCM x3 : 1.1029 uA  BCM x10: 7.3748 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:-3.913E-05     BCM u3 [0]:0.0005692      BCM u10[0]:-4.932E-06     
    
    BCM d1 [0]:0.003743       BCM d3 [0]:-4.316E-06     BCM d10[0]:0.003782       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4859 at Sun Nov 8 01:06:51 EST 2009
    
    Left Arm Top VDC Current : -1.70898
    Left Arm Bottom VDC Current : 2.7832
    Left Arm Top VDC voltage : 4.00049
    Left Arm Bottom VDC voltage : 4
    -----
    Right Arm Top VDC Current : -5.61523
    Right Arm Bottom VDC Current : 0.634766
    Right Arm Top VDC voltage : 3.99658
    Right Arm Bottom VDC voltage : 4.01562
    -----
    Left Arm Q1 momentum : 3.66043
    Left Arm Q1 power supply : 2753.8
    Left Arm Q1 gauss meter : -0.23216
    Left Arm Q2 gauss meter : 0.8272
    Left Arm Q2 power supply current : 1575.85
    Left Arm Q2 momentum : 3.65966
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.23
    Left Arm D1 momentum : 3.6601
    Left Arm D1 NMR : 1.35578
    Left Arm arm angle : 12.8988
    Left Arm Q3 gauss meter : -0.73461
    Left Arm Q3 power supply current : 1457.2
    Left Arm Q3 momentum : 3.66023
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 2.62965
    Right Arm Q1 power supply : 1977.33
    Right Arm Q1 gauss meter : -0.04911
    Right Arm Q2 power supply current : 1132.11
    Right Arm Q2 momentum : 2.63057
    Right Arm Q2 gauss meter : 0.5924
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 932.856
    Right Arm D1 momentum : 2.63002
    Right Arm D1 NMR : 0.97597
    Right Arm arm angle : 20.001
    Right Arm Q3 power supply current : 394.286
    Right Arm Q3 momentum : 0.990895
    Right Arm Q3 gauss meter : 0.19379
    Right Arm Q3 power supply polarity : disabled
    -----
    Average current of the two cavities : 15.3472
    Current on Unser monitor : 33.0974
    Current on Upstream bcm : 14.9417
    Current on Downstream bcm : 15.7527
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 15.4514
    Hall C Current : 0
    MBSY1c magnet current (amp) : 254.343
    MBSY1c Bdl : 1.51764e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.38
    Hall A momentum orbit correction (dpp) : -1.27508e-05
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6067.38
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 0.761379
    IPM1C12.XPOS : -0.00453824
    IPM1H04A.XPOS : -2.8826
    IPM1H04A.YPOS : 1.92728
    IPM1H04B.XPOS : -2.99449
    IPM1H04B.YPOS : 1.98727
    -----
    Wien angle : 74.7279
    Wien BDL : 1724.8
    Wien field : 49.796
    Laser attenuation Hall A : 80
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    -----
    Target : Optics
    fan frequency loop 1 : 59.5
    fan frequency loop 3 : 0
    Encoder position : 1.26745e+07
    Target type : 1.26745e+07
    temperature loop 1(1) : 22.01
    temperature loop 1(2) : 21.97
    temperature loop 1(3) : 22.28
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.5
    Heat exchange LH2 : 273.4
    HPH H2 loop 1 : 1043.88
    HPH H2 loop 3 : 9.38936e-06