Privacy and Security Notice
Start_Parity_Run_13805__CODA_Config=PvdNoQweak_Run_type=Test,beam_energy=3.4839,beam_polarization=87,beam_raster=on,comment_text=oversample tests, OS=1, 80 uA,dithering_magnet=off,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=off,parity_ihwp=out,rightarm_p=pi,rightarm_theta=14,target_fanspeed=60,target_type=20cm LD2
Main INDEX
Monthly INDEX
PREV
NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 07:17:08 on November 8, 2009
Entry number 298294
keyword=Start_Parity_Run_13805__CODA_Config=PvdNoQweak_Run_type=Test,beam_energy=3.4839,beam_polarization=87,beam_raster=on,comment_text=oversample tests, OS=1, 80 uA,dithering_magnet=off,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=off,parity_ihwp=out,rightarm_p=pi,rightarm_theta=14,target_fanspeed=60,target_type=20cm LD2
Beginning-of-Parity-run EPICS data for Run Number 13805 at Sun Nov 8 07:15:58 EST 2009
CODA Configuration: PvdNoQweak
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 20904
-----------------------------------------
Wien angle : 74.7279
Wien BDL : 1724.8
Wien field : 49.796
Laser attenuation Hall A : 94
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.3
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5.05
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.681
Gun2: PC (PITA) NEG : 7.019
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.74603
Pockels Cell Voltage NEG : 1.54579
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 cycles
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 500
Helicity Delay Read : 8 cycles
Helicity Pattern Read : Quartet
Helicity Frequency : 29.5596
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr741mW
Calculated power in cavity : 0.269796
Photodiode on table : 391.825
Laser X position on QPD 1 : 111.534
Laser Y position on QPD 1 : 522.824
Laser X position on QPD 2 : 19.1663
Laser Y position on QPD 2 : -606.608
QPD 1 sum : -1.52963
QPD 2 sum : -1.20125
Position set point for adjustable
mirror 1 (either x or y) : -1520[c]
Position set point for adjustable
mirror 2 (either x or y) : -1420[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.2177
Polarisation in cavity : LEFT
Reflection photodiode : 0.834401
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.151987
Fast locking signal sent to laser : -5.2646
Calculated polarisation in cavity : 69.9905
Photodiode 1 after Wollaston prism : 0.0536011
Photodiode 2 after Wollaston prism : 0.00946252
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.05
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
Left S1 HV
S1 Slot1 ch0 : -1660.9
S1 Slot1 ch1 : -1785.3
S1 Slot1 ch2 : -1621.1
S1 Slot1 ch3 : -1676.5
S1 Slot1 ch4 : -1657.1
S1 Slot1 ch5 : -1870.7
S1 Slot1 ch6 : -1836.6
S1 Slot1 ch7 : -1675.6
S1 Slot1 ch8 : -1556.9
S1 Slot1 ch9 : -1621.1
S1 Slot1 ch10 : -1746.5
S1 Slot1 ch11 : -1760.6
-----
Left S2 HV Left PMTs
S2 Slot0 ch0 Left : -1639.8
S2 Slot0 ch1 Left : -1690.8
S2 Slot0 ch2 Left : -2015.9
S2 Slot0 ch3 Left : -1820.9
S2 Slot0 ch4 Left : -1858.4
S2 Slot0 ch5 Left : -1661.7
S2 Slot0 ch6 Left : -1837.5
S2 Slot0 ch7 Left : -1803.6
S2 Slot0 ch8 Left : -1795.8
S2 Slot0 ch9 Left : -1918.4
S2 Slot0 ch10 Left : -1975.6
S2 Slot0 ch11 Left : -1822.9
S2 Slot13 ch0 Left : -1954.5
S2 Slot13 ch1 Left : -2006.7
S2 Slot13 ch2 Left : -1776.6
S2 Slot13 ch3 Left : -1559.8
-----
Left S2 HV Right PMTs
S2 Slot12 ch0 Right : -1484.3
S2 Slot12 ch1 Right : -1627.6
S2 Slot12 ch2 Right : -1780.8
S2 Slot12 ch3 Right : -1699.9
S2 Slot12 ch4 Right : -1758
S2 Slot12 ch5 Right : -1731.7
S2 Slot12 ch6 Right : -1765.1
S2 Slot12 ch7 Right : -1472.1
S2 Slot12 ch8 Right : -1825.3
S2 Slot12 ch9 Right : -1700
S2 Slot12 ch10 Right : -1829.3
S2 Slot12 ch11 Right : -1550.9
S2 Slot13 ch4 Right : -1553
S2 Slot13 ch5 Right : -1635.9
S2 Slot13 ch6 Right : -1650
S2 Slot13 ch7 Right : -1626.6
-----
Left Cerenkov HV
GCER Slot2 ch0 : -1522.3
GCER Slot2 ch1 : -1436.5
GCER Slot2 ch2 : -1511.2
GCER Slot2 ch3 : -1421.2
GCER Slot2 ch4 : -1766.4
GCER Slot2 ch5 : -1990.5
GCER Slot2 ch6 : -14.8
GCER Slot2 ch7 : -1724.8
GCER Slot2 ch8 : -1960.8
GCER Slot2 ch9 : -1520.5
GCER Slot2 ch10 : -1745.2
GCER Slot2 ch11 : -14.6
-----
Left Pion Rejector Layer 1 HV
PRL1 Slot3 ch0 : -900.3
PRL1 Slot3 ch1 : -815.1
PRL1 Slot3 ch2 : -931.9
PRL1 Slot3 ch3 : -985.8
PRL1 Slot3 ch4 : -787.1
PRL1 Slot3 ch5 : -886.9
PRL1 Slot3 ch6 : -1095
PRL1 Slot3 ch7 : -1012.6
PRL1 Slot3 ch8 : -834.9
PRL1 Slot3 ch9 : -816.1
PRL1 Slot3 ch10 : -886.6
PRL1 Slot3 ch11 : -809.5
PRL1 Slot4 ch0 : -901.1
PRL1 Slot4 ch1 : -931.4
PRL1 Slot4 ch2 : -768.2
PRL1 Slot4 ch3 : -942
PRL1 Slot4 ch4 : -921.7
PRL1 Slot4 ch5 : -901.3
PRL1 Slot4 ch6 : -920.2
PRL1 Slot4 ch7 : -796.5
PRL1 Slot4 ch8 : -884
PRL1 Slot4 ch9 : -810.7
PRL1 Slot4 ch10 : -911.3
PRL1 Slot4 ch11 : -851.5
PRL1 Slot5 ch0 : -885.9
PRL1 Slot5 ch1 : -829.7
PRL1 Slot5 ch2 : -778.7
PRL1 Slot5 ch3 : -836.2
PRL1 Slot5 ch4 : -840.9
PRL1 Slot5 ch5 : -755.2
PRL1 Slot5 ch6 : -800.4
PRL1 Slot5 ch7 : -860.3
PRL1 Slot5 ch8 : -881.3
PRL1 Slot5 ch9 : -968.3
PRL1 Slot5 ch10 : -5
PRL1 Slot5 ch11 : -14.9
-----
Left Pion Rejector Layer 2 HV
PRL2 Slot9 ch0 : -804.7
PRL2 Slot9 ch1 : -796.3
PRL2 Slot9 ch2 : -820.8
PRL2 Slot9 ch3 : -772.6
PRL2 Slot9 ch4 : -720.6
PRL2 Slot9 ch5 : -901
PRL2 Slot9 ch6 : -795.8
PRL2 Slot9 ch7 : -990.2
PRL2 Slot9 ch8 : -924.2
PRL2 Slot9 ch9 : -865.2
PRL2 Slot9 ch10 : -1080.7
PRL2 Slot9 ch11 : -1054.4
PRL2 Slot10 ch0 : -807
PRL2 Slot10 ch1 : -861.3
PRL2 Slot10 ch2 : -1009.7
PRL2 Slot10 ch3 : -904.5
PRL2 Slot10 ch4 : -864.8
PRL2 Slot10 ch5 : -825.6
PRL2 Slot10 ch6 : -838.1
PRL2 Slot10 ch7 : -829.4
PRL2 Slot10 ch8 : -1190.4
PRL2 Slot10 ch9 : -1041.2
PRL2 Slot10 ch10 : -1081.1
PRL2 Slot10 ch11 : -836.5
PRL2 Slot11 ch0 : -1075.5
PRL2 Slot11 ch1 : -900.4
PRL2 Slot11 ch2 : -946.3
PRL2 Slot11 ch3 : -765.8
PRL2 Slot11 ch4 : -914.8
PRL2 Slot11 ch5 : -823.8
PRL2 Slot11 ch6 : -839
PRL2 Slot11 ch7 : -890.5
PRL2 Slot11 ch8 : -785.9
PRL2 Slot11 ch9 : -840.6
PRL2 Slot11 ch10 : -2.9
PRL2 Slot11 ch11 : -11.7
-----
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 2753.75
Left Arm Q1 momentum : 3.66036
Left Arm Q1 gauss meter : -0.23215
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1575.82
Left Arm Q2 momentum : 3.65958
Left Arm Q2 gauss meter : 0.8272
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : -1.356
Left Arm D1 momentum : 0.000233833
Left Arm D1 NMR : 0.716303
Left Arm Q3 power supply current : 1457.18
Left Arm Q3 momentum : 3.66016
Left Arm Q3 gauss meter : -0.73451
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 1977.49
Right Arm Q1 momentum : 2.62986
Right Arm Q1 gauss meter : -0.04912
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1132.09
Right Arm Q2 momentum : 2.63052
Right Arm Q2 gauss meter : 0.5925
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 993.283
Right Arm D1 momentum : 2.53654
Right Arm D1 NMR : 0.941471
Right Arm Q3 power supply current : -0.00284706
Right Arm Q3 momentum : -7.6809e-06
Right Arm Q3 gauss meter : 9.32e-05
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents & Voltages
-----------------------------------------
Left Arm Top VDC Current : 1.51367
Left Arm Bottom VDC Current : 1.5625
Right Arm Top VDC Current : -1.70898
Right Arm Bottom VDC Current : -1.46484
Left Arm Top VDC voltage : 0.0180664
Left Arm Bottom VDC voltage : 0.0185547
Right Arm Top VDC voltage : -0.0107422
Right Arm Bottom VDC voltage : -0.00195312
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 65.9959
Current on Unser monitor : 80.4773
Current on Upstream bcm : 62.3271
Current on Downstream bcm : 69.6648
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 65.9885
Tiefenbach Hall A energy : 6067.37
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 0.761379
MBSY1c Hall A Beam energy : 6081.48
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 254.343
MBSY1c Bdl : 1.51764e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 6
Raster Y width : 6
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0.00201783
IPM1C12.YPOS : 0.21649
IPM1H04A.XPOS : -2.90086
IPM1H04A.YPOS : 1.9813
IPM1H04B.XPOS : -2.9851
IPM1H04B.YPOS : 1.97994
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : -0.00409496
Survey Y offset bpm12 : 0.182333
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
Left Arm Collimator
-----------------------------------------
Left Arm Collimator : 0.367432
HacL_HPE1313A:0_Ch58 : -0.243164
HacL_HPE1313A:0_Ch55 : 23.1934
HacL_HPE1313A:0_Ch54 : 0.0825195
Left Arm Angle Floor Angle : 13
Left Arm Angle Vernier : 13.5
Left Arm Scattering Angle : 12.8988
-----------------------------------------
Right Arm Collimator
-----------------------------------------
Right Arm Collimator : 0.0249512
HacR_HPE1313A:0_Ch58 : -0.588379
HacR_HPE1313A:0_Ch55 : 22.3633
HacR_HPE1313A:0_Ch54 : -0.911133
Right Arm Angle Floor Angle : 20
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 20.001
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L1 20cm
Encoder position : 33077688
fan frequency loop 1 : 59.5
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 22.06
temperature loop 1-2 : 22.02
temperature loop 1-3 : 22.5
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 99.99
temperature loop 3-2 : 99.99
temperature loop 3-3 : 29.99
pressure fill target H2 : 25.4978
pressure fill bottle H2 : 25.6977
pressure ballast H2 : 25.7664
pressure exhaust H2 : 24.5701
cryogen input temp : 218.7
crogen return flow : 0
JT valve setting : -0.488281
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 0
anatype fdbk
curmon bcm1
curmonc bcm10
feedback PITA on 1 bcm1
feedback IA off 1 bcm1
feedback IAHallC on 5 bcm10
IAHallCparam slope 200.0
IAparam slope 1.0
PITAparam slope -4749
ncuts 6
cutnames Low_beam Beam_burp Evt_seq Pair_seq Startup Low_beam_c
extlo 10 10 25 25 0 10
exthi 1200 40 25 25 1 1200
#
# command to log run in database (should already have been done)\n
/adaqfs/home/apar/pvdis/runlistDB/addRun2runlist.pl -r 13805 -d '2009-11-08 07:15:51' -t 33077688 -s OUT