     Run Number: 25626
     End of Run Comment:
    Run_type=Production,target_type=LD2, 20cm,beam_e0=6.06,beam_raster=on,beam_current=100,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=20.0,rightarm_sieve=out,comment_text=Production
     
    
    PRESCALE FACTORS:ps1=350   ps2=700   ps3=1   ps4=3   ps5=20   ps6=3000   ps7=2000   ps8=65535   
    
    EVENTS   : [0]: 1709389      
    TIME     : [0]: 56.321 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:   3.66%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :422.0/147688.7 Hz   T2[0] : 4.4/3067.7 Hz   T3[0] : 7.5/7.5  Hz   T4[0] : 8.6/25.9 Hz   T5[0] : 9.7/193.3 Hz   T6[0] : 8.7/25973.0 Hz   T7[0] :76.4/152798.8 Hz   T8[0] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :1425942/499079868  T2[0] :  14809/10366751  T3[0] :  25472/25472    T4[0] :  29185/87555    T5[0] :  32666/653338   T6[0] :  29256/87769788  T7[0] : 258174/516348438  T8[0] :     52/3460372  
    
    AVERAGE CURRENT
    BCM x1 : 40.2490uA  BCM x3 : 40.0488uA  BCM x10: 22.6185uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.1356         BCM u3 [0]:0.1356         BCM u10[0]:0.079          
    
    BCM d1 [0]:0.1364         BCM d3 [0]:0.1351         BCM d10[0]:0.07386        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 25626 at Fri Nov 20 08:58:57 EST 2009
    
    Left Arm Top VDC Current : 1.51367
    Left Arm Bottom VDC Current : 1.5625
    Left Arm Top VDC voltage : 0.019043
    Left Arm Bottom VDC voltage : 0.019043
    -----
    Right Arm Top VDC Current : -1.80664
    Right Arm Bottom VDC Current : -1.41602
    Right Arm Top VDC voltage : 0.00439453
    Right Arm Bottom VDC voltage : -0.0102539
    -----
    Left Arm Q1 momentum : 3.66022
    Left Arm Q1 power supply : 2753.64
    Left Arm Q1 gauss meter : -0.23217
    Left Arm Q2 gauss meter : 0.8272
    Left Arm Q2 power supply current : 1575.86
    Left Arm Q2 momentum : 3.65968
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.33
    Left Arm D1 momentum : 3.66003
    Left Arm D1 NMR : 1.35575
    Left Arm arm angle : 12.8971
    Left Arm Q3 gauss meter : -0.73446
    Left Arm Q3 power supply current : 1457.13
    Left Arm Q3 momentum : 3.66003
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 2.62979
    Right Arm Q1 power supply : 1977.43
    Right Arm Q1 gauss meter : -0.04915
    Right Arm Q2 power supply current : 1132.05
    Right Arm Q2 momentum : 2.63042
    Right Arm Q2 gauss meter : 0.5921
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 931.522
    Right Arm D1 momentum : 2.63002
    Right Arm D1 NMR : 0.975969
    Right Arm arm angle : 20.001
    Right Arm Q3 power supply current : 1046.68
    Right Arm Q3 momentum : 2.63044
    Right Arm Q3 gauss meter : 0.4683
    Right Arm Q3 power supply polarity : disabled
    -----
    Average current of the two cavities : 0.0338913
    Current on Unser monitor : 18.3932
    Current on Upstream bcm : 0.0421839
    Current on Downstream bcm : 0.0255987
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 0.00461185
    Hall C Current : 0
    MBSY1c magnet current (amp) : 254.343
    MBSY1c Bdl : 1.51764e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.46
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6067.46
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 2.61465
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Wien angle : 74.7279
    Wien BDL : 1723.07
    Wien field : 49.796
    Laser attenuation Hall A : 70
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : IN
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    -----
    Target : L1 20cm
    fan frequency loop 1 : 59.5
    fan frequency loop 3 : 0
    Encoder position : 3.30777e+07
    Target type : 3.30777e+07
    temperature loop 1(1) : 22.22
    temperature loop 1(2) : 21.99
    temperature loop 1(3) : 22.32
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.5
    Heat exchange LH2 : 268
    HPH H2 loop 1 : 986.703
    HPH H2 loop 3 : 0.0244217