Privacy and Security Notice

End_of_Run_25628


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 09:59:52 on November 20, 2009

    Entry number 301287

    keyword=End_of_Run_25628
    ****************************
     Run Number: 25628
     End of Run Comment:
    Run_type=Production,target_type=LD2, 20cm,beam_e0=6.06,beam_raster=on,beam_current=100,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=20.0,rightarm_sieve=out,comment_text=Production
     
    
    PRESCALE FACTORS:ps1=350   ps2=700   ps3=1   ps4=3   ps5=20   ps6=3000   ps7=2000   ps8=65535   
    
    EVENTS   : [0]: 722054       
    TIME     : [0]: 13.070 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:   4.22%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :776.2/271675.1 Hz   T2[0] : 7.8/5440.9 Hz   T3[0] :12.1/12.1 Hz   T4[0] :14.2/42.5 Hz   T5[0] :15.9/317.4 Hz   T6[0] :15.9/47651.7 Hz   T7[0] :139.2/278474.0 Hz   T8[0] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 608703/213046308  T2[0] :   6095/4266756  T3[0] :   9501/9501     T4[0] :  11108/33324    T5[0] :  12446/248920   T6[0] :  12456/37368215  T7[0] : 109188/218377979  T8[0] :     12/803016   
    
    AVERAGE CURRENT
    BCM x1 : 73.6484uA  BCM x3 : 73.5834uA  BCM x10: 44.4785uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.05778        BCM u3 [0]:0.05777        BCM u10[0]:0.03533        
    
    BCM d1 [0]:0.05773        BCM d3 [0]:0.05764        BCM d10[0]:0.03443        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 25628 at Fri Nov 20 09:59:48 EST 2009
    
    Left Arm Top VDC Current : 1.46484
    Left Arm Bottom VDC Current : 1.51367
    Left Arm Top VDC voltage : 0.0185547
    Left Arm Bottom VDC voltage : 0.019043
    -----
    Right Arm Top VDC Current : -1.75781
    Right Arm Bottom VDC Current : -1.51367
    Right Arm Top VDC voltage : 0.00488281
    Right Arm Bottom VDC voltage : -0.0102539
    -----
    Left Arm Q1 momentum : 3.66022
    Left Arm Q1 power supply : 2753.7
    Left Arm Q1 gauss meter : -0.23214
    Left Arm Q2 gauss meter : 0.8272
    Left Arm Q2 power supply current : 1575.86
    Left Arm Q2 momentum : 3.65969
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.33
    Left Arm D1 momentum : 3.66004
    Left Arm D1 NMR : 1.35576
    Left Arm arm angle : 12.8971
    Left Arm Q3 gauss meter : -0.73434
    Left Arm Q3 power supply current : 1457.12
    Left Arm Q3 momentum : 3.66001
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 2.62979
    Right Arm Q1 power supply : 1977.43
    Right Arm Q1 gauss meter : -0.04914
    Right Arm Q2 power supply current : 1132.04
    Right Arm Q2 momentum : 2.63041
    Right Arm Q2 gauss meter : 0.5921
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 931.522
    Right Arm D1 momentum : 2.63004
    Right Arm D1 NMR : 0.975978
    Right Arm arm angle : 20.001
    Right Arm Q3 power supply current : 1046.67
    Right Arm Q3 momentum : 2.63044
    Right Arm Q3 gauss meter : 0.4683
    Right Arm Q3 power supply polarity : disabled
    -----
    Average current of the two cavities : 89.9156
    Current on Unser monitor : 108.465
    Current on Upstream bcm : 87.8282
    Current on Downstream bcm : 92.003
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 90.1921
    Hall C Current : 0
    MBSY1c magnet current (amp) : 254.343
    MBSY1c Bdl : 1.51764e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.38
    Hall A momentum orbit correction (dpp) : -1.24639e-05
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6067.38
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 1.56836
    IPM1C12.XPOS : 0.0160783
    IPM1H04A.XPOS : -0.716925
    IPM1H04A.YPOS : 0.0830278
    IPM1H04B.XPOS : -0.705984
    IPM1H04B.YPOS : 0.0556359
    -----
    Wien angle : 74.7279
    Wien BDL : 1723.07
    Wien field : 49.796
    Laser attenuation Hall A : 184
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : IN
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    -----
    Target : L1 20cm
    fan frequency loop 1 : 60
    fan frequency loop 3 : 0
    Encoder position : 3.30777e+07
    Target type : 3.30777e+07
    temperature loop 1(1) : 22.37
    temperature loop 1(2) : 21.99
    temperature loop 1(3) : 22.55
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.8
    Heat exchange LH2 : 268
    HPH H2 loop 1 : 250.084
    HPH H2 loop 3 : 0.011068