Privacy and Security Notice

End_of_Run_5196


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 16:57:46 on November 20, 2009

    Entry number 301413

    keyword=End_of_Run_5196
    ****************************
     Run Number: 5196
     End of Run Comment:
    Run_type=Production,target_type=LD2, 20cm,beam_e0=6.06,beam_raster=on,beam_current=115,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=20,rightarm_sieve=out,comment_text=Production
     
    
    PRESCALE FACTORS:ps1=80   ps2=300   ps3=300   ps4=10   ps5=200   ps6=200   ps7=4000   ps8=65535   
    
    EVENTS   : [0]: 3001640      
    TIME     : [0]: 49.683 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:   4.39%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :965.1/77208.5 Hz   T2[0] :10.3/3080.3 Hz   T3[0] : 8.9/2669.0 Hz   T4[0] :16.2/162.2 Hz   T5[0] :18.6/3715.1 Hz   T6[0] :18.4/3680.1 Hz   T7[0] :16.9/67497.2 Hz   T8[0] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :2876933/230154681  T2[0] :  30607/9182373  T3[0] :  26520/7956052  T4[0] :  48363/483636   T5[0] :  55373/11074622  T6[0] :  54851/10970256  T7[0] :  50301/201205833  T8[0] :     46/3052494  
    
    AVERAGE CURRENT
    BCM x1 : 43.2927uA  BCM x3 : 84.0726uA  BCM x10: -23.5422uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:-0.0004555     BCM u3 [0]:0.2552         BCM u10[0]:-0.06838       
    
    BCM d1 [0]:0.2586         BCM d3 [0]:0.246          BCM d10[0]:-0.07198       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 5196 at Fri Nov 20 16:57:42 EST 2009
    
    Left Arm Top VDC Current : 1.51367
    Left Arm Bottom VDC Current : 1.51367
    Left Arm Top VDC voltage : 0.0180664
    Left Arm Bottom VDC voltage : 0.0185547
    -----
    Right Arm Top VDC Current : -1.61133
    Right Arm Bottom VDC Current : -1.41602
    Right Arm Top VDC voltage : 0.00488281
    Right Arm Bottom VDC voltage : -0.0112305
    -----
    Left Arm Q1 momentum : 3.66022
    Left Arm Q1 power supply : 2753.7
    Left Arm Q1 gauss meter : -0.23215
    Left Arm Q2 gauss meter : 0.8272
    Left Arm Q2 power supply current : 1575.85
    Left Arm Q2 momentum : 3.65967
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.33
    Left Arm D1 momentum : 3.66004
    Left Arm D1 NMR : 1.35576
    Left Arm arm angle : 12.8971
    Left Arm Q3 gauss meter : -0.73442
    Left Arm Q3 power supply current : 1457.11
    Left Arm Q3 momentum : 3.65999
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 2.62979
    Right Arm Q1 power supply : 1977.43
    Right Arm Q1 gauss meter : -0.04915
    Right Arm Q2 power supply current : 1132.04
    Right Arm Q2 momentum : 2.63041
    Right Arm Q2 gauss meter : 0.5921
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 931.49
    Right Arm D1 momentum : 2.62999
    Right Arm D1 NMR : 0.975957
    Right Arm arm angle : 20.001
    Right Arm Q3 power supply current : 1046.67
    Right Arm Q3 momentum : 2.63043
    Right Arm Q3 gauss meter : 0.4682
    Right Arm Q3 power supply polarity : disabled
    -----
    Average current of the two cavities : 113.701
    Current on Unser monitor : 131.966
    Current on Upstream bcm : 110.688
    Current on Downstream bcm : 116.715
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 113.859
    Hall C Current : 0
    MBSY1c magnet current (amp) : 254.343
    MBSY1c Bdl : 1.51764e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.37
    Hall A momentum orbit correction (dpp) : -1.52239e-05
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6067.37
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 5.04817
    IPM1C12.XPOS : -0.00686327
    IPM1H04A.XPOS : -0.714386
    IPM1H04A.YPOS : 0.0658578
    IPM1H04B.XPOS : -0.716677
    IPM1H04B.YPOS : 0.0341198
    -----
    Wien angle : 74.7279
    Wien BDL : 1723.07
    Wien field : 49.796
    Laser attenuation Hall A : 245
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : IN
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    -----
    Target : L1 20cm
    fan frequency loop 1 : 59.5
    fan frequency loop 3 : 0
    Encoder position : 3.30777e+07
    Target type : 3.30777e+07
    temperature loop 1(1) : 22.41
    temperature loop 1(2) : 21.99
    temperature loop 1(3) : 22.6
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.8
    Heat exchange LH2 : 267.5
    HPH H2 loop 1 : 80.6127
    HPH H2 loop 3 : 0.011068