Privacy and Security Notice

Start_Run_5228,Run_type=Pedestal,target_type=LD2, 20cm,beam_e0=6.06,beam_raster=on,beam_current=100,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=20,rightarm_sieve=out,comment_text=procuction, 97uA


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 05:36:10 on November 22, 2009

    Entry number 301748

    keyword=Start_Run_5228,Run_type=Pedestal,target_type=LD2, 20cm,beam_e0=6.06,beam_raster=on,beam_current=100,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=20,rightarm_sieve=out,comment_text=procuction, 97uA
    Run Timestamp:       Sun Nov 22 05:35:23 EST 2009
    Beginning-of-run EPICS data for Run Number 5228 at Sun Nov 22 05:35:58 EST 2009
    
    
    
    Run_type=Pedestal
    target_type=LD2, 20cm
    beam_e0=6.06
    beam_raster=on
    beam_current=100
    leftarm_p=3.66
    leftarm_theta=12.9
    leftarm_sieve=out
    rightarm_p=2.63
    rightarm_theta=20
    rightarm_sieve=out
    comment_text=procuction, 97uA
    
    
    ; R-HRS DAQ on adaql2/a-onl account
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Change this file only in-between runs.
    ; Maxima: (2^24)-1 = 16777215 for T1-T4 and 65535 for T5-T8
    ; The default factor is essentially infinite.
    ; T1 = R-HRS HAPPEX Trigger
    ; T2 = R-HRS S0 trigger (of most importance)
    ; T3 = R-HRS PREX Detector 
    ; T4-T7 = Eventually PVDIS stuff
    ; T8 = 1024 Hz p1ulser
    ; String should be one line, no spaces, ending in carriage return
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    
     ps1=80,ps2=300,ps3=300,ps4=10,ps5=400,ps6=400,ps7=4000,ps8=100
    ; ps1=1,ps2=16777215,ps3=16777215,ps4=16777215,ps5=65535,ps6=65535,ps7=65535,ps8=65535
    ; ps1=1,ps2=50,ps3=30,ps4=1,ps5=40,ps6=40,ps7=4000,ps8=65535
    
    
    
    Left Arm Q1 momentum : 3.66015
    Left Arm Q1 power supply : 2753.64
    Left Arm Q1 gauss meter : -0.23213
    Left Arm Q2 power supply current : 1575.85
    Left Arm Q2 momentum : 3.65966
    Left Arm Q2 gauss meter : 0.8271
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.33
    Left Arm D1 momentum : 3.66003
    Left Arm D1 NMR : 1.35575
    Left Arm Q3 power supply current : 1457.1
    Left Arm Q3 momentum : 3.65997
    Left Arm Q3 gauss meter : -0.73438
    Left Arm Q3 power supply polarity : disabled
    Left Arm B Field Hall Probe (D-G) : -1.3058
    -----
    Right Arm Q1 momentum : 2.62972
    Right Arm Q1 power supply : 1977.43
    Right Arm Q1 gauss meter : -0.04915
    Right Arm Q2 power supply current : 1132.04
    Right Arm Q2 momentum : 2.63039
    Right Arm Q2 gauss meter : 0.592
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 931.492
    Right Arm D1 momentum : 2.63
    Right Arm D1 NMR : 0.975962
    Right Arm Q3 power supply current : 1046.66
    Right Arm Q3 momentum : 2.6304
    Right Arm Q3 gauss meter : 0.4683
    Right Arm Q3 power supply polarity : disabled
    Right Arm B Field Hall Probe (D-G) : -0.9642
    -----
    Left Arm Top VDC Current : 1.51367
    Left Arm Bottom VDC Current : 1.46484
    Left Arm Top VDC voltage : 0.0180664
    Left Arm Bottom VDC voltage : 0.0175781
    -----
    Right Arm Top VDC Current : -1.66016
    Right Arm Bottom VDC Current : -1.46484
    Right Arm Top VDC voltage : -0.0102539
    Right Arm Bottom VDC voltage : -0.00537109
    -----
    Average current of the two cavities : 98.3098
    Current on Unser monitor : 116.18
    Current on Upstream bcm : 95.9871
    Current on Downstream bcm : 100.633
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 98.7685
    Hall C Current : 0
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.37
    Hall A momentum orbit correction (dpp) : -1.48201e-05
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6067.37
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 4.71649
    MBSY1c magnet current (amp) : 254.343
    MBSY1c Bdl : 1.51764e+06
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    Raster X width : 6
    Raster Y width : 6
    -----
    HacL_HPE1313A:0_Ch58 : -0.254395
    HacL_HPE1313A:0_Ch55 : 23.3398
    HacL_HPE1313A:0_Ch54 : 0.0703125
    Left Arm Angle Floor Angle : 13
    Left Arm Angle Vernier : 13.2
    Left Arm Scattering Angle : 12.8971
    -----
    Right Arm D1 momentum : 2.63
    Right Arm arm angle : 20.001
    -----
    Left VDC -DISC LVL Top : 3.8877
    Left VDC -DISC LVL Bottom : 3.97021
    Left VDC -DISC LVL Voltage1 : 4.97705
    Left VDC -DISC LVL Voltage2 : -5.06885
    -----
    Right Arm Arm Collimator : 0.00537109
    HacR_HPE1313A:0_Ch58 : -0.59082
    HacR_HPE1313A:0_Ch55 : 22.3633
    HacR_HPE1313A:0_Ch54 : -0.910156
    Right Arm Angle Floor Angle : 20
    Right Arm Angle Vernier : -34
    Right Arm Scattering Angle : 20.001
    -----
    IPM1C12.XPOS : -0.0160463
    IPM1C12.YPOS : 0.153824
    IPM1H04A.XPOS : -0.671862
    IPM1H04A.YPOS : 0.069481
    IPM1H04B.XPOS : -0.689428
    IPM1H04B.YPOS : 0.0516099
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    -----
    Wien angle : 74.7279
    Wien BDL : 1723.07
    Wien field : 49.796
    Laser attenuation Hall A : 237
    Laser power Hall A : 100
    Half-wave plate (off=out) : IN
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : IN
    -----
    Helicity Delay Set : 8 cycles
    Helicity Pattern Set : Quartet
    Helicity Clock Set : Free Clock
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    Helicity Clock Read : Free Clock
    Helicity Frequency : 29.5596
    -----
    Target : L1 20cm
    fan frequency loop 1 : 59.5
    fan frequency loop 2 : 0
    fan frequency loop 3 : 0
    Encoder position : 3.30777e+07
    Target type : 3.30777e+07
    temperature loop 1(1) : 22.48
    temperature loop 1(2) : 22
    temperature loop 1(3) : 22.56
    Heat exchange loop 1 H2 : 24.8
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange loop 3 H2 : 268.8
    pressure loop He : 47.4753
    pressure loop H2 before : 25.7862
    pressure loop H2 return : 24.5777
    HPH He loop 1 : 227.257
    HPH He loop 2 : 0.00123869
    HPH H2 loop 3 : 0.00293052
    
    Left S2 HV Left PMTs
    S2 Slot0 ch0 Left : -1640.5
    S2 Slot0 ch1 Left : -1690.1
    S2 Slot0 ch2 Left : -2015.1
    S2 Slot0 ch3 Left : -1820.9
    S2 Slot0 ch4 Left : -1858.4
    S2 Slot0 ch5 Left : -1661.7
    S2 Slot0 ch6 Left : -1836.8
    S2 Slot0 ch7 Left : -1803.6
    S2 Slot0 ch8 Left : -1795.8
    S2 Slot0 ch9 Left : -1919.2
    S2 Slot0 ch10 Left : -1976.3
    S2 Slot0 ch11 Left : -1822.9
    S2 Slot13 ch0 Left : -1954.5
    S2 Slot13 ch1 Left : -2006.7
    S2 Slot13 ch2 Left : -1776.6
    S2 Slot13 ch3 Left : -1559.8
    -----
    Left S2 HV Right PMTs
    S2 Slot12 ch0 Right : -1484.3
    S2 Slot12 ch1 Right : -1627.6
    S2 Slot12 ch2 Right : -1780.8
    S2 Slot12 ch3 Right : -1699.9
    S2 Slot12 ch4 Right : -1758
    S2 Slot12 ch5 Right : -1731.7
    S2 Slot12 ch6 Right : -1765.1
    S2 Slot12 ch7 Right : -1472.1
    S2 Slot12 ch8 Right : -1825.3
    S2 Slot12 ch9 Right : -1700
    S2 Slot12 ch10 Right : -1829.3
    S2 Slot12 ch11 Right : -1550.9
    S2 Slot13 ch4 Right : -1553
    S2 Slot13 ch5 Right : -1635.9
    S2 Slot13 ch6 Right : -1650
    S2 Slot13 ch7 Right : -1626.6
    -----
    Left S1 HV
    S1 Slot1 ch0 : -1660.9
    S1 Slot1 ch1 : -1785.3
    S1 Slot1 ch2 : -1621.1
    S1 Slot1 ch3 : -1676.5
    S1 Slot1 ch4 : -1657.1
    S1 Slot1 ch5 : -1870.7
    S1 Slot1 ch6 : -1836.6
    S1 Slot1 ch7 : -1675.6
    S1 Slot1 ch8 : -1556.9
    S1 Slot1 ch9 : -1621.1
    S1 Slot1 ch10 : -1746.5
    S1 Slot1 ch11 : -1760.6
    -----
    Left Cerenkov HV
    GCER Slot2 ch0 : -1522.3
    GCER Slot2 ch1 : -1437.2
    GCER Slot2 ch2 : -1511.2
    GCER Slot2 ch3 : -1421.2
    GCER Slot2 ch4 : -1766.4
    GCER Slot2 ch5 : -1990.5
    GCER Slot2 ch6 : -16.3
    GCER Slot2 ch7 : -1724.8
    GCER Slot2 ch8 : -1960.8
    GCER Slot2 ch9 : -1520.5
    GCER Slot2 ch10 : -1745.2
    GCER Slot2 ch11 : -15.3
    -----
    Left Pion Rejector Layer 1 HV
    PRL1 Slot3 ch0 : -900.3
    PRL1 Slot3 ch1 : -815.1
    PRL1 Slot3 ch2 : -931.9
    PRL1 Slot3 ch3 : -986.6
    PRL1 Slot3 ch4 : -787.1
    PRL1 Slot3 ch5 : -886.9
    PRL1 Slot3 ch6 : -1095
    PRL1 Slot3 ch7 : -1012.6
    PRL1 Slot3 ch8 : -834.9
    PRL1 Slot3 ch9 : -816.1
    PRL1 Slot3 ch10 : -886.6
    PRL1 Slot3 ch11 : -809.5
    PRL1 Slot4 ch0 : -901.1
    PRL1 Slot4 ch1 : -932.2
    PRL1 Slot4 ch2 : -768.2
    PRL1 Slot4 ch3 : -941.2
    PRL1 Slot4 ch4 : -921.7
    PRL1 Slot4 ch5 : -902.1
    PRL1 Slot4 ch6 : -920.2
    PRL1 Slot4 ch7 : -796.5
    PRL1 Slot4 ch8 : -883.2
    PRL1 Slot4 ch9 : -810.7
    PRL1 Slot4 ch10 : -911.3
    PRL1 Slot4 ch11 : -851.5
    PRL1 Slot5 ch0 : -885.9
    PRL1 Slot5 ch1 : -829.7
    PRL1 Slot5 ch2 : -778.7
    PRL1 Slot5 ch3 : -836.2
    PRL1 Slot5 ch4 : -840.9
    PRL1 Slot5 ch5 : -755.2
    PRL1 Slot5 ch6 : -800.4
    PRL1 Slot5 ch7 : -860.3
    PRL1 Slot5 ch8 : -881.3
    PRL1 Slot5 ch9 : -968.3
    PRL1 Slot5 ch10 : -5
    PRL1 Slot5 ch11 : -14.9
    -----
    Left Pion Rejector Layer 2 HV
    PRL2 Slot9 ch0 : -804.7
    PRL2 Slot9 ch1 : -796.3
    PRL2 Slot9 ch2 : -820.8
    PRL2 Slot9 ch3 : -772.6
    PRL2 Slot9 ch4 : -720.6
    PRL2 Slot9 ch5 : -901
    PRL2 Slot9 ch6 : -795.8
    PRL2 Slot9 ch7 : -990.2
    PRL2 Slot9 ch8 : -924.2
    PRL2 Slot9 ch9 : -865.2
    PRL2 Slot9 ch10 : -1080.7
    PRL2 Slot9 ch11 : -1054.4
    PRL2 Slot10 ch0 : -806.2
    PRL2 Slot10 ch1 : -861.3
    PRL2 Slot10 ch2 : -1009.7
    PRL2 Slot10 ch3 : -904.5
    PRL2 Slot10 ch4 : -864.8
    PRL2 Slot10 ch5 : -825.6
    PRL2 Slot10 ch6 : -838.1
    PRL2 Slot10 ch7 : -829.4
    PRL2 Slot10 ch8 : -1190.4
    PRL2 Slot10 ch9 : -1041.2
    PRL2 Slot10 ch10 : -1081.1
    PRL2 Slot10 ch11 : -836.5
    PRL2 Slot11 ch0 : -1075.5
    PRL2 Slot11 ch1 : -900.4
    PRL2 Slot11 ch2 : -946.3
    PRL2 Slot11 ch3 : -765.8
    PRL2 Slot11 ch4 : -914.8
    PRL2 Slot11 ch5 : -823.8
    PRL2 Slot11 ch6 : -839
    PRL2 Slot11 ch7 : -890.5
    PRL2 Slot11 ch8 : -785.9
    PRL2 Slot11 ch9 : -840.6
    PRL2 Slot11 ch10 : -2.9
    PRL2 Slot11 ch11 : -11.7
    -----
    # Map  RHRS_VDC  Measured Voltage
     -4000 
    # Map  RHRS_VDC  Measured Current
        -0 
    # Map  RHRS_PMTS  Measured Voltage
      1 :   -650   -700   -701   -657   -646   -703  -2121   -703  -1920  -1079  -1060   -976   -857  -2582     -6 
      2 :   -712   -699   -701   -668   -713   -669  -2131   -723  -1831  -1116   -992  -1094  -1046  -2542   -556 
      3 :   -729   -700   -700   -659   -601   -674  -2051   -718  -1690  -1075   -976  -1126  -1035  -2532   -648 
      4 :   -796   -700     -9   -688   -607   -665  -1902   -750  -2000  -1083  -1067  -1062  -1051  -2666     -6 
      5 :   -694   -701   -687   -668   -669   -672  -1712   -851  -1602  -1073  -1072  -1026  -1107  -2465   -830 
      6 :   -714   -700   -690   -666   -625   -661  -1952   -805  -1791  -1044  -1055  -1090  -1141  -2580   -951 
      7 :   -702   -700   -673   -826   -657   -662  -2051    -12  -1821  -1056  -1146  -1106  -1189  -2601   -682 
      8 :   -670   -701   -647     -9   -664   -612  -2076    -17  -2092  -1070  -1056  -1074  -1266  -2591   -667 
      9 :   -679   -700   -659   -670   -698   -668  -2002    -18  -1752  -1069  -1209  -1040  -1076  -2426     -6 
     10 :   -696   -701   -658   -680   -679   -668  -2152    -22  -1722  -1068  -1114  -1039   -967  -2543     -6 
     11 :   -650   -700   -639   -662   -750   -661  -1772    -20  -1822  -1069   -976  -1085   -978    -17  -1042 
     12 :   -679   -701   -678   -649    -12   -718  -2083    -18  -1712  -1054   -976  -1102  -1001    -29   -556 
    # Map  RHRS_PMTS  Measured Current
      1 :   -155   -167   -167   -155   -154   -164  -1303   -167   -866   -277   -271   -250   -220   -484      0 
      2 :   -169   -166   -167   -159   -170   -164  -1309   -172   -826   -286   -254   -280   -269   -476   -344 
      3 :   -175   -167   -166   -157   -143   -162  -1260   -171   -762   -276   -250   -289   -265   -473   -405 
      4 :   -190   -167      0   -164   -144   -163  -1168   -178   -902   -278   -274   -272   -270   -508      1 
      5 :   -165   -166   -164   -159   -159   -163   -772   -202   -723   -275   -274   -263   -284   -438   -512 
      6 :   -170   -167   -164   -158   -149   -162  -1196   -192   -808   -267   -271   -279   -293   -498   -590 
      7 :   -167   -166   -160   -196   -157   -162  -1259     -0   -821   -271   -293   -284   -304   -492   -422 
      8 :   -160   -167   -154     -0   -158   -150  -1276     -0   -943   -274   -271   -276   -325   -488   -416 
      9 :   -161   -166   -156   -160   -166   -163  -1227      0   -790   -275   -310   -266   -276   -448     -0 
     10 :   -166   -167   -156   -162   -162   -164  -1321     -0   -775   -274   -286   -267   -248   -476      0 
     11 :   -155   -166   -152   -158   -179   -163  -1087      0  -1114   -274   -250   -278   -251      0   -646 
     12 :   -162   -167   -161   -155      0   -172  -1274     -0  -1049   -270   -251   -282   -257     -0   -341 
    CODA config : config RightHrs LeftHrs
    HAPPEX run : 14136