Privacy and Security Notice

End_of_Run_25696


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 22:00:10 on November 22, 2009

    Entry number 301932

    keyword=End_of_Run_25696
    ****************************
     Run Number: 25696
     End of Run Comment:
    Run_type=Calibration,target_type=Aluminium Dummy,beam_e0=6.06,beam_raster=on,beam_current=10,leftarm_p=3.66,leftarm_theta=12.9,leftarm_sieve=out,rightarm_p=2.63,rightarm_theta=20.0,rightarm_sieve=out,comment_text=Q2 measurement
     
    
    PRESCALE FACTORS:ps1=24   ps2=999999   ps3=99999   ps4=99999   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : [0]: 894509       
    TIME     : [0]: 13.755 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:   0.16%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :1084.9/26038.8 Hz   T2[0] : 0.0/359.9 Hz   T3[0] : 0.0/0.2  Hz   T4[0] : 0.0/0.4  Hz   T5[0] : 0.0/4.0  Hz   T6[0] : 0.1/5101.5 Hz   T7[0] : 0.5/33502.3 Hz   T8[0] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 895421/21490119  T2[0] :      0/297033   T3[0] :      0/178      T4[0] :      0/331      T5[0] :      0/3303     T6[0] :     64/4210298  T7[0] :    421/27649801  T8[0] :     12/845119   
    
    AVERAGE CURRENT
    BCM x1 : 45.6755uA  BCM x3 : 45.6721uA  BCM x10: 40.5790uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.03776        BCM u3 [0]:0.03777        BCM u10[0]:0.03382        
    
    BCM d1 [0]:0.03763        BCM d3 [0]:0.03761        BCM d10[0]:0.03316        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 25696 at Sun Nov 22 22:00:06 EST 2009
    
    Left Arm Top VDC Current : 1.51367
    Left Arm Bottom VDC Current : 1.51367
    Left Arm Top VDC voltage : 0.0180664
    Left Arm Bottom VDC voltage : 0.019043
    -----
    Right Arm Top VDC Current : -1.61133
    Right Arm Bottom VDC Current : -1.41602
    Right Arm Top VDC voltage : -0.00976562
    Right Arm Bottom VDC voltage : -0.0107422
    -----
    Left Arm Q1 momentum : 3.66007
    Left Arm Q1 power supply : 2753.54
    Left Arm Q1 gauss meter : -0.23213
    Left Arm Q2 gauss meter : 0.8272
    Left Arm Q2 power supply current : 1575.86
    Left Arm Q2 momentum : 3.65967
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1325.34
    Left Arm D1 momentum : 3.66003
    Left Arm D1 NMR : 1.35575
    Left Arm arm angle : 12.8971
    Left Arm Q3 gauss meter : -0.73456
    Left Arm Q3 power supply current : 1457.11
    Left Arm Q3 momentum : 3.65998
    Left Arm Q3 power supply polarity : disabled
    -----
    Right Arm Q1 momentum : 2.62979
    Right Arm Q1 power supply : 1977.43
    Right Arm Q1 gauss meter : -0.04916
    Right Arm Q2 power supply current : 1132.04
    Right Arm Q2 momentum : 2.6304
    Right Arm Q2 gauss meter : 0.5921
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 931.493
    Right Arm D1 momentum : 2.62999
    Right Arm D1 NMR : 0.975957
    Right Arm arm angle : 20.001
    Right Arm Q3 power supply current : 1046.67
    Right Arm Q3 momentum : 2.63042
    Right Arm Q3 gauss meter : 0.4682
    Right Arm Q3 power supply polarity : disabled
    -----
    Average current of the two cavities : 0.0311489
    Current on Unser monitor : 18.74
    Current on Upstream bcm : 0.0372461
    Current on Downstream bcm : 0.0250518
    Upstream Cavity Coefficient : 42.6
    Downstream Cavity Coefficient : 43.8
    Current on IBC0L02 (source) : 0.0102962
    Hall C Current : 0
    MBSY1c magnet current (amp) : 254.343
    MBSY1c Bdl : 1.51764e+06
    Hall A momentum (Tiefenbach) (HALLA:p) : 6067.46
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 6067.5
    Hall A energy (halla_MeV) : 6067.46
    Hall C energy (hallc_MeV) : 6070.48
    Delta(E)/E width (MV_AI_DXWID) : 1.38376
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    -----
    Wien angle : 74.7279
    Wien BDL : 1723.07
    Wien field : 49.796
    Laser attenuation Hall A : 70
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 1200
    Beam Half-wave plate (off=out) : OUT
    -----
    Helicity Settle Read : 500
    Helicity Delay Read : 8 cycles
    Helicity Pattern : Quartet
    -----
    Target : Dummy
    fan frequency loop 1 : 60
    fan frequency loop 3 : 0
    Encoder position : 1.18016e+07
    Target type : 1.18016e+07
    temperature loop 1(1) : 22.41
    temperature loop 1(2) : 22.01
    temperature loop 1(3) : 22.33
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 99.99
    temperature loop 3(3) : 29.99
    Heat exchange LH2 : 24.6
    Heat exchange LH2 : 268.4
    HPH H2 loop 1 : 1059.29
    HPH H2 loop 3 : 0.011068