Privacy and Security Notice

RUNP TJNAF Hall A FPP Chamber 3 Cabling Map

Rutgers University Experimental Nuclear Physics

Intermediate Energy Focal Plane Polarimeter

FPP Chamber 3 Cabling Map

Introduction

In reading this map, it must be remembered that a group of eight straws is multiplexed into a single readout line, using logical pulses of eights different widths. The widths for the eight straws are, in order, about 25, 45, 35, 55, 85-90, 65, 100-105, and 75 ns.

If the readout board is mounted facing the straws so that the straw numbers increase from right to left, then the readout cable will have on channel i straw numbers off+1 -> off+8 and on channel i+1 straw numbers off+9 -> off+16. The level shifter switches the order of the channels in the cable, so the TDC (counting 1->16, rather than 0 -> 15) gets straws off+9 -> off+16 in channel 15-i and straws off+1 -> off+8 in channel 16-i. This is the case for both the chamber 3 X and V planes, X1, X2, V7, and V8.

If the readout board is mounted facing the straws so that the straw numbers decrease from right to left, then the readout cable will have on channel i straw numbers off+16 -> off+9 and on channel i+1 straw numbers off+8 -> off+1. After the level shifter, the order becomes straws off+8 -> off+1 in channel 15-i and straws off+16 -> off+9 in channel 16-i. This is the case for the chamber 3 U planes, U7 and U8.

Also note that the cable labels at the inputs to the TDCs show the order of the modules/stacks at the chamber, not the reversed order (by the level shifters) at the TDC inputs.

Readout Cable Map

TDC in slot 6, input cable 5, channels 65-80
TDC 6 chan chmbr - RO cable plane straw #s wire group board HV cable pulser order
65, 66 3 - 5 - 16, 15 U7 184-177, 192-185 23, 24 U7-M12 1-C 8
67, 68 3 - 5 - 14, 13 U8 184-177, 192-185 23, 24 U8-M12 1-C 8
69, 70 3 - 5 - 12, 11 U7 200-193, 208-201 25, 26 U7-M13 1-B 9
71, 72 3 - 5 - 10, 9 U8 200-193, 208-201 25, 26 U8-M13 1-B 9
73, 74 3 - 5 - 8, 7 U7 216-209, 224-217 27, 28 U7-M14 1-A 10
75, 76 3 - 5 - 6, 5 U8 216-209, 224-217 27, 28 U8-M14 1-A 10
77, 78 3 - 5 - 4, 3 U7 232-225, 240-233 29, 30 U7-M15 2-F 11
79, 80 3 - 5 - 2, 1 U8 232-225, 240-233 29, 30 U8-M15 2-F 11
TDC in slot 6, input cable 6, channels 81-96
TDC 6 chan chmbr - RO cable plane straw #s wire group board HV cable pulser order
81, 82 3 - 6 - 16, 15 V7 233-240, 225-232 30, 29 V7-M15 3-A 16
83, 84 3 - 6 - 14, 13 V8 233-240, 225-232 30, 29 V8-M15 3-A 16
85, 86 3 - 6 - 12, 11 V7 217-224, 209-216 28, 27 V7-M14 3-D 15
87, 88 3 - 6 - 10, 9 V8 217-224, 209-216 28, 27 V8-M14 3-D 15
89, 90 3 - 6 - 8, 7 V7 201-208, 193-200 26, 25 V7-M13 3-C 14
91, 92 3 - 6 - 6, 5 V8 201-208, 193-200 26, 25 V8-M13 3-C 14
93, 94 3 - 6 - 4, 3 V7 185-192, 177-184 24, 23 V7-M12 3-B 13
95, 96 3 - 6 - 2, 1 V8 185-192, 177-184 24, 23 V8-M12 3-B 13
TDC in slot 7, input cable 1, channels 1-16
TDC 7 chan chmbr - RO cable plane straw #s wire group board HV cable pulser order
1, 2 3 - 7 - 16, 15 U7 8-1, 16-9 1, 2 U7-M1 4-F 33
3, 4 3 - 7 - 14, 13 U8 8-1, 16-9 1, 2 U8-M1 4-F 33
5, 6 3 - 7 - 12, 11 V7 153-160, 145-152 20, 19 V7-M10 1-D 11
7, 8 3 - 7 - 10, 9 V8 153-160, 145-152 20, 19 V8-M10 1-D 11
9, 10 3 - 7 - 8, 7 NA NA NA NA NA NA
11, 12 3 - 7 - 6, 5 NA NA NA NA NA NA
13, 14 3 - 7 - 4, 3 V7 169-176, 161-168 22, 21 V7-M11 4-A 12
15, 16 3 - 7 - 2, 1 V8 169-176, 161-168 22, 21 V8-M11 4-A 12
TDC in slot 7, input cable 2, channels 17-32
TDC 7 chan chmbr - RO cable plane straw #s wire group board HV cable pulser order
17, 18 3 - 8 - 16, 15 U7 40-33, 48-41 5, 6 U7-M3 4-D 35
19, 20 3 - 8 - 14, 13 U8 40-33, 48-41 5, 6 U8-M3 4-D 35
21, 22 3 - 8 - 12, 11 V7 121-128, 113-120 16, 15 V7-M8 1-B 9
23, 24 3 - 8 - 10, 9 V8 121-128, 113-120 16, 15 V8-M8 1-B 9
25, 26 3 - 8 - 8, 7 U7 24-17, 32-25 3, 4 U7-M2 4-E 34
27, 28 3 - 8 - 6, 5 U8 24-17, 32-25 3, 4 U8-M2 4-E 34
29, 30 3 - 8 - 4, 3 V7 137-144, 129-136 18, 17 V7-M9 1-C 10
31, 32 3 - 8 - 2, 1 V8 137-144, 129-136 18, 17 V8-M9 1-C 10
TDC in slot 7, input cable 3, channels 33-48
TDC 7 chan chmbr - RO cable plane straw #s wire group board HV cable pulser order
33, 34 3 - 1 - 16, 15 X2 57-64, 49-56 8, 7 X2-M4 5-D 29
35, 36 3 - 1 - 14, 13 X1 57-64, 49-56 8, 7 X1-M4 5-D 29
37, 38 3 - 1 - 12, 11 X2 41-48, 33-40 6, 5 X2-M3 5-C 30
39, 40 3 - 1 - 10, 9 X1 41-48, 33-40 6, 5 X1-M3 5-C 30
41, 42 3 - 1 - 8, 7 X2 25-32, 17-24 4, 3 X2-M2 5-B 31
43, 44 3 - 1 - 6, 5 X1 25-32, 17-24 4, 3 X1-M2 5-B 31
45, 46 3 - 1 - 4, 3 X2 9-16, 1-8 2, 1 X2-M1 5-A 32
47, 48 3 - 1 - 2, 1 X1 9-16, 1-8 2, 1 X1-M1 5-A 32
TDC in slot 7, input cable 4, channels 49-56
TDC 7 chan chmbr - RO cable plane straw #s wire group board HV cable pulser order
49, 50 3 - 2 - 16, 15 X2 121-128, 113-120 16, 15 X2-M8 5-H 25
51, 52 3 - 2 - 14, 13 X1 121-128, 113-120 16, 15 X1-M8 5-H 25
53, 54 3 - 2 - 12, 11 X2 105-112, 97-104 14, 13 X2-M7 5-G 26
55, 56 3 - 2 - 10, 9 X1 105-112, 97-104 14, 13 X1-M7 5-G 26
57, 58 3 - 2 - 8, 7 X2 89-96, 81-88 12, 11 X2-M6 5-F 27
59, 60 3 - 2 - 6, 5 X1 89-96, 61-88 12, 11 X1-M6 5-F 27
61, 62 3 - 2 - 4, 3 X2 73-80, 65-72 10, 9 X2-M5 5-E 28
63, 64 3 - 2 - 2, 1 X1 73-80, 56-72 10, 9 X1-M5 5-E 28
TDC in slot 7, input cable 5, channels 65-80
TDC 7 chan chmbr - RO cable plane straw #s wire group board HV cable pulser order
65, 66 3 - 3 - 16, 15 X2 185-192, 177-184 24, 23 X2-M12 6-D 21
67, 68 3 - 3 - 14, 13 X1 185-192, 177-184 24, 23 X1-M12 6-D 21
69, 70 3 - 3 - 12, 11 X2 169-176, 161-168 22, 21 X2-M11 6-C 22
71, 72 3 - 3 - 10, 9 X1 169-176, 161-168 22, 21 X1-M11 6-C 22
73, 74 3 - 3 - 8, 7 X2 153-160, 145-152 20, 19 X2-M10 6-B 23
75, 76 3 - 3 - 6, 5 X1 153-160, 145-152 20, 19 X1-M10 6-B 23
77, 78 3 - 3 - 4, 3 X2 137-144, 129-136 18, 17 X2-M9 6-A 24
79, 80 3 - 3 - 2, 1 X1 137-144, 129-136 18, 17 X1-M9 6-A 24
TDC in slot 7, input cable 6, channels 81-96
TDC 7 chan chmbr - RO cable plane straw #s wire group board HV cable pulser order
81, 82 3 - 4 - 16, 15 X2, X1 241-248, 241-248 31, 31 X2b,X1a-M16 6-H 17
83, 84 3 - 4 - 14, 13 NA NA NA NA NA NA
85, 86 3 - 4 - 12, 11 X2 233-240, 225-232 30, 29 X2-M15 6-G 18
87, 88 3 - 4 - 10, 9 X1 233-240, 225-232 30, 29 X1-M15 6-G 18
89, 90 3 - 4 - 8, 7 X2 217-224, 209-216 28, 27 X2-M14 6-F 19
91, 92 3 - 4 - 6, 5 X1 217-224, 209-216 28, 27 X1-M14 6-F 19
93, 94 3 - 4 - 4, 3 X2 201-208, 193-200 26, 25 X2-M13 6-E 20
95, 96 3 - 4 - 2, 1 X1 201-208, 193-200 26, 25 X1-M13 6-E 20
TDC in slot 8, input cable 1, channels 1-16
TDC 8 chan chmbr - RO cable plane straw #s wire group board HV cable pulser order
1, 2 3 - 9 - 16, 15 U7 72-65, 80-73 9, 10 U7-M5 4-B 1
3, 4 3 - 9 - 14, 13 U8 72-65, 80-73 9, 10 U8-M5 4-B 1
5, 6 3 - 9 - 12, 11 V7 89-96, 81-88 12, 11 V7-M6 2-F 7
7, 8 3 - 9 - 10, 9 V8 89-96, 81-88 12, 11 V8-M6 2-F 7
9, 10 3 - 9 - 8, 7 U7 56-49, 64-57 7, 8 U7-M4 4-C 36
11, 12 3 - 9 - 6, 5 U8 56-49, 64-57 7, 8 U8-M4 4-C 36
13, 14 3 - 9 - 4, 3 V7 105-112, 97-104 14, 13 V7-M7 1-A 8
15, 16 3 - 9 - 2, 1 V8 105-112, 97-104 14, 13 V8-M7 1-A 8
TDC in slot 8, input cable 2, channels 17-32
TDC 8 chan chmbr - RO cable plane straw #s wire group board HV cable pulser order
17, 18 3 - 10 - 16, 15 U7 104-97, 112-105 13, 14 U7-M7 3-D 3
19, 20 3 - 10 - 14, 13 U8 104-97, 112-105 13, 14 U8-M7 3-D 3
21, 22 3 - 10 - 12, 11 V7 57-64, 49-56 8, 7 V7-M4 2-D 5
23, 24 3 - 10 - 10, 9 V8 57-64, 49-56 8, 7 V8-M4 2-D 5
25, 26 3 - 10 - 8, 7 U7 88-81, 96-89 11, 12 U7-M6 3-A 2
27, 28 3 - 10 - 6, 5 U8 88-81, 96-89 11, 12 U8-M6 3-A 2
29, 30 3 - 10 - 4, 3 V7 73-80, 65-72 10, 9 V7-M5 2-E 6
31, 32 3 - 10 - 2, 1 V8 73-80, 65-72 10, 9 V8-M5 2-E 6
TDC in slot 8, input cable 3, channels 33-48
TDC 8 chan chmbr - RO cable plane straw #s wire group board HV cable pulser order
33, 34 3 - 11 - 16, 15 U7 136-129, 144-137 17, 18 U7-M9 3-B 5
35, 36 3 - 11 - 14, 13 U8 136-129, 144-137 17, 18 U8-M9 3-B 5
37, 38 3 - 11 - 12, 11 V7 25-32, 17-24 2, 1 V7-M2 2-B 3
39, 40 3 - 11 - 10, 9 V8 25-32, 17-24 2, 1 V8-M2 2-B 3
41, 42 3 - 11 - 8, 7 U7 120-113, 128-121 7, 8 U7-M8 3-C 4
43, 44 3 - 11 - 6, 5 U8 120-113, 128-121 7, 8 U8-M8 3-C 4
45, 56 3 - 11 - 4, 3 V7 41-48, 33-40 6, 5 V7-M3 2-C 4
47, 48 3 - 11 - 2, 1 V8 41-48, 33-40 6, 5 V8-M3 2-C 4
TDC in slot 8, input cable 4, channels 49-64
TDC 8 chan chmbr - RO cable plane straw #s wire group board HV cable pulser order
49, 50 3 - 12 - 16, 15 U7 168-161, 176-169 21, 22 U7-M11 1-D 7
51, 52 3 - 12 - 14, 13 U8 168-161, 176-169 21, 22 U8-M11 1-D 7
53, 54 3 - 12 - 12, 11 NA NA NA NA NA NA
55, 56 3 - 12 - 10, 9 NA NA NA NA NA NA
57, 58 3 - 12 - 8, 7 U7 152-145, 160-153 19, 20 U7-M10 4-A 6
59, 60 3 - 12 - 6, 5 U8 152-145, 160-153 19, 20 U8-M10 4-A 6
61, 62 3 - 12 - 4, 3 V7 9-16, 1-8 2, 1 V7-M1 2-A 2
63, 64 3 - 12 - 2, 1 V8 9-16, 1-8 2, 1 V8-M1 2-A 2


Summary Table

Cables 3-1, 3-2, 3-3, 3-4
channels 3-1 board label 3-2 board label 3-3 board label 3-4 board label
1, 2 X2-1AB X2-5AB X2-9AB X2-13AB
3, 4 X1-1AB X1-5AB X1-9AB X1-13AB
5, 6 X2-2AB X2-6AB X2-10AB X2-14AB
7, 8 X1-2AB X1-6AB X1-10AB X1-14AB
9, 10 X2-3AB X2-7AB X2-11AB X2-15AB
11, 12 X1-3AB X1-7AB X1-11AB X1-15AB
13, 14 X2-4AB X2-8AB X2-12AB -
15, 16 X1-4AB X1-8AB X1-112AB X1-16A1, X2-16B2
1 no wire 7, 8 2 no wire 6, 7, 8

Cables 3-5, 3-6, 3-7, 3-8
channels 3-5 board label 3-6 board label 3-7 board label 3-8 board label
1, 2 U2-15AB1 V2-12AB V2-11AB V2-9AB
3, 4 U1-15AB2 V1-12AB V1-11AB V1-9AB
5, 6 U2-14AB V2-13AB - U2-2AB
7, 8 U1-14AB V1-13AB - U1-2AB
9, 10 U2-13AB V2-14AB V2-10AB V2-8AB
11, 12 U1-13AB V1-14AB V1-10AB V1-8AB
13, 14 U2-12AB V2-15AB U2-1AB3 U2-3AB
15, 16 U1-12AB V1-15AB U1-1AB U1-3AB
1: no wire a1 2: no wire a1 3: misdocumented a2, a3 as bad straws, actually b6, b7 missing

Cables 3-9, 3-10, 3-11, 3-12
channels 3-9 board label 3-10 board label 3-11 board label 3-12 board label
1, 2 V2-7AB V2-5AB V2-3AB V2-1AB1
3, 4 V1-7AB V1-5AB V1-3AB V1-1AB2
5, 6 U2-4AB U2-6AB U2-8AB U2-10AB
7, 8 U1-4AB U1-6AB U1-8AB U1-10AB
9, 10 V2-6AB V2-4AB V2-2AB -
11, 12 V1-6AB V1-4AB V1-2AB -
13, 14 U2-5AB U2-7AB U2-9AB U2-11AB
15, 16 U1-5AB U1-7AB U1-9AB U1-11AB
1 no wire a1 2 no wire a1, a2; a5 bad straw / disconnected


Back to Rutgers Physics Home Page

Please send any comments on this page to Ronald Gilman, gilman@ruthep.rutgers.edu .

Created October 27, 1996 Ronald Gilman