Since the original construction of Chamber 3, we have modified and (hopefully) improved procedures somewhat. This document lists procedures and changes in procedures. Wenever the chamber 3 electronics is worked upon, any card stacks installed ``old style'' should be modified for the new style.
To remove a stack of cards, you must disconnect all wires to the chamber straws -- it is only necessary to disconnect them from the board.
* WARNING * Disconnecting wires from the straws, unless done carefully, can break the wire in the straw. DO NOT DO THIS!
For HV stacks, you should probably disconnect the test pulser cable form the rear of the boards; for readout stacks, you should disconnect the readout phone connectors and the low voltage power connectors. This may not be necessary if you are moving the stack aside instead of removing it.
When you pull the stack back from the straws, BE CAREFUL NOT TO PULL ON ANY WIRES, OR YOU MAY PULL ON A STRAW PIN AND BREAK THE WIRE IN THE STRAW.
RG finds it easiest to tilt the back end of the stack upward, to failitate removal.
Installing the readout and high voltage cards on the rear FPP chambers can be tricky. Following are a number of hints to make installation easier.
Several details have changed in how the card stacks are installed. If you remove / work on a stack that does not have the redone features, please redo it. The modified details include the following: