Helicity signals in the electron arm - November 5, 1998 ======================================================= LOGIC ----- CAMAC NIM NIM LeCroy 2323A LeCroy 222 Phillips Gate & Delay Gate & Delay fan-in/fan-out Generator Generator for out signals below +-----------------+ +--------+ | GATE & DELAY | +---> ADC,#62,Slot 25 | Delay | | | | (h+) ---+----| 200 us |---------->|o start out o|--+---> SCALER (#5) | | | +---->|o stop --- | | +--------+ | +-->|o blank out-bar o|------> CEAN/SCALER veto | . . | | +-----------------+ +-----------------+ | | . . . . | | | . . . . | | | . . . . | | | . . . . | | | . . +-----------------|-+ | . . | . . | | +-----------------+ | +--------+ | | | GATE & DELAY | +---> ADC,#63,Slot 25 | | Delay | | | | | | (h-) ---+----| 200 us |---|---|-->|o start out o|--+---> SCALER (#6) | | +---|-->|o stop --- | +--------+ +-->|o blank out-bar o|------> CEAN/SCALER veto | +-----------------+ | (GO/rungate NIM-bar fanout) ---+ ADC-Signal-wiring ================= e-Spectr. Patch panel: TOP BACK FRONT --- ---- ----- Betty Betty Eunice' Eunice' *** ADC *** from h+ ---> C-15 ---//---> C-15 --> D-15 ---//---> D-15 --> Slot 25,#62 from h- ---> C-16 ---//---> C-16 --> D-16 ---//---> D-16 --> Slot 25,#63 from Steffen Strauch note: RG 11/17/98 h+ and h- scaler channels were originally set to 6 and 7, but were switched to 5 and 6 on ~ Nov 6.