Privacy and Security Notice

E1F TOF Calibration

RF Calibration for e1f

The first two plots show the fits from which the rf constants were produced. The fit results from 37658 were applied to 37658 and 37659. The results from 37664 were applied to 37664-38687 (end of e1f). The same set of constants had already been computed from 37662 and applied to 37661-37662. Please see the information I had posted about this on Mauri's Wiki for a more detailed explanation of this calibration process (go to calibrations -> TOF -> e1f tof calibration -> RF calibration).



The following plot is the rf signal for 37664 with original constants in the database.


The remaining eight the plots come from the monitoring histograms produced in the cooking of the new pass0 utilizing the constants produced above.




Please contact Wes Gohn with questions.