Privacy and Security Notice
Settings for fpp_deut_q16
-
Goal
To measure the ratio of proton's electric to magnetic form factor to
5% for Q2 = 1.6 GeV2 in deuterium
-
Beam Energy
1.67 GeV
-
Carbon Blocks
9"+6"+1.5"
-
Beam position
less than 0.25 for x and y for 3A and 3B
-
Raster size
2.0x2.0mm in SPOT .
-
Beam Current
Maximum possible. Expect rate of 65 hz at 40 microA.
-
Target
15cm LD2
-
Spectrometer settings
| Spectrometer |
Momentum |
Angle |
Collimator |
| Electron |
0.809 GeV |
66.23° |
open or 6msr |
|
|
|
|
| Proton |
1.532 GeV |
28.91° |
open or 6msr |
-
Data taking
-
The collimator setting will be decided by doing quick runs
with the open collimator and the 6msr.
If the raw T5 rate increases by more than 20% with open collimator then
use open. Otherwise use 6msr setting.
-
The T5 prescale should be one.
-
The prescales for T1,T2,T3 and T4 should be set to give less
than 2 Hz trigger rate for each. The T8 prescale should be set to maximum.
-
The trigger setup needs to be set for proton momentum.
-
Need to modify the header file: hdr_fpp_89028_q16d
-
The data taking time is estimated to be 22.0 hours. Will
need to update after looking at carbon scattering efficiency.
-
Need 1.2x10+6 total triggers with good fpp and
scattering between 5 and 20 degrees in carbon .