In the directory /work/halla/ndelta-2/databases are the following files. 1. The database optimizing beta, scint adc and vdc for runs 1025 to 1765 is db_ndelta_1765_vdc_opt . This database also has the correct coefficients for the BPM determined by Zhengwei Chai 2. The database db_835_e_emily has electron arm delta optimized by Emilie Penel for Dec 1999 12C elastic data. 3. The database db_ndelta_3.5 has electron theta,phi and ytgt and y000,t000, and p000 optimized by Nilanga. He started with the VCS 3.5 GeV database Optimized the t000,y000 and p000 using run 1760 Then optimize the theta and phi using 1H data and sieve using a reduced number of elements in theta. The optimized the Y030 element . For now the delta matrix is used unchanged. There are no T000 nor Y000 terms for electron optics in this database. 4. The database db_840_dp_h_rikki has hadron arm delta optimized by Rikki Roche for Dec 1999 12C elastic data. 5. The database db3500_e_zwchai is an improved version of db_ndelta_3.5 for electron arm optics. 6. The database db845_e_zwchai has the electron arm theta,phi and ytgt optimized using the Dec 1999 845 data. 7. The database db845_h_zwchai has the hadron arm theta,phi and ytgt optimized using the Dec 1999 845 data. 8. The database db700_1400_h_zwchai has the hadron arm the ytgt and y000,p000,t000 optimized using 700MeV, 1.0GeV 1.3GeV ndelta pointing data 9. The database db_ndelta_e4000_h840_nilanga has improved delta for electron and hadron. The electron D000,D100 and D200 were changed to improve the resolution for 12C and 3He(e,ep) data at 4 GeV. The hadron 10. After new collimator survey Zhengwei optimized the detector offsets. There are in db_ndelta_pd1_new_zwchai 11. The database db_ndelta_period1 has a) the beta,scint adc and vdc from db_ndelta_1765_vdc_opt b) the bpm coefficients from db_ndelta_1765_vdc_opt c) electron theta,phi and y from db3500_e_zwchai d) electron delta from db_ndelta_e4000_h840_nilanga e) hadron delta from db_ndelta_e4000_h840_nilanga f) hadron phi,theta from db845_h_zwchai g) hadron ytgt from db700_1400_h_zwchai h) t000,y000,p000 from db_ndelta_pd1_new_zwchai for electron and hadron. 11. On 1/3/01, Nilanga did the determination of the gamma for the spectrometers using 800 MeV 12C elastics. I added the gammas to db_ndelta_period1 . When I calculate spectrometer constants for 89044 (12/99), ndelta (05/00) and 97111 (10/00) optics data, this is what I get 89044 ndelta 97111 Gamma_e 270.2 270.2 270.3 Gamma_h 269.8 269.8 269.9 Each with an uncertainty of about 0.15 I used only the EP measurements for these, There is an ARC measurement for the 89044 setting, and if I use that the numbers become 270.1 and 269.7 respectively. So I think it is safe to use Gamma_e=270.2 +/- 0.15 and Gamma_h=269.8 +/- 0.15 In addition Nilanga looked at the dependence of gamma on the central field by looking at the missing mass peak in 12C(e,ep) inelastic for electron arm between 500 and 4000 MeV/c . He found a dependence starting around 2500 MeV/c so Left: 0.0000E-01 2.702E+02 0.0000E-01 -1.57E-03 Right: 0.0000E-01 2.698E+02 0.0000E-01 -1.57E-03 These changes were added to the database db_ndelta_period1 So for example pcent (MeV/c) = 270.2*B - 1.57e-3*B^3 where B is dipole field in kG. 12. Zhengwei determined ytgt from 700,1.0,1.3 data. Is this the best way to do it? Should we optimize at each.