Privacy and Security Notice
Last revised 24-Jan-01
January 2001 H(e,e'K) Runplan
Preliminaries
-
Before
Starting: Before beginning
check the beam conditions. The OTR should be in (if possible). Fast
feedback should also be on, both energy and orbit locks and locked to
Hall A. The 15 cm LH2 target should be in, and the MCC should be told
to setup for 75 uA (but that we want to start at 25 uA first).
-
Beam Energy:
5.618 GeV. If different by more than 5 MeV (as measured by the Hall
A arc-integral B*dl or the Hall A ep), get an updated table of kinematics
from P. Markowitz. If there is any difficulty either with the energy or
the locks, contact A. Saha.
-
Beam position: Less than
0.100 mm for x and y for 3A and 3B
Raster size:
2.0x2.0mm in SPOT or smaller.
Beam Current:
Start at 25 microA on the 15 cm LH2. Expect singles rates of 40 Khz at
25 microA.
Target:
15cm LH2
First Setting
-
Kinematics:
We will start at the Q2=2.35 (GeV/c)2, W=1.80 GeV,
high epsilon setting.
Spectrometer settings
| Spectrometer |
Momentum |
Angle |
Collimator |
| Right |
-3.077 GeV/c |
21.14° |
6msr |
| Left |
+1.741 GeV/c |
22.40° |
6msr |
-
Data taking
Set the magnets first. The
electron arm (e.g., the right HRS) is CLOSE to the administrative maximum
momentum of 3.14 GeV/c. Pay attention as the dipole ramps up. Call John
LeRose if there is any difficulty. HALOG the magnet screen.
Change the angles simultaneously.
HALOG the angles and the vernier settings.
While the magnets
are ramping, perform a harp scan and a beam current calibration. HALOG
the results.
The trigger
setup needs to be set for a electron in the right arm and a kaon (of
momentum PK=1.741) in the left arm. Coincidence gate
width should be 50 ns.
The prescales for
T1,T2,T3 and T4 should be set to give less than 10 Hz trigger rate for
each. T5 should be set to 1. The T8 prescale should be set to
maximum. HALOG the prescale values.
Need to
check the header file : hdr_kaon1
The data
taking time is estimated to be 4.0 hours. Will need to update by doing
a simultaneous replay. Also check detector spectra with the detector
kumac.
Take a
short (15 minute) run at 25 uA then increase current to 75 uA and take
the rest of the data.
Take a
short (15 minute) run at 25 uA on the 15 cm empty
target.
Put in the
multifoil target and take a 5 minute mainly singles run. Remember to
change the prescales to 1 for T1 and T3. Keep T2 and T4 at less than
50 Hz. Use a beam current of 10 uA.
Second setting
Kinematics:
The second
setting is at the Q2=2.35 (GeV/c)2, W=1.85 GeV,
high epsilon setting.
Settings: Change the
electron arm first then take a 5 minute single arm run with the
multifoil targets. Then change the hadron arm and take another 5
minute single arm run with the multifoil target.
Beam and Target:
Double check that fast feedback locks on both energy and orbit are on.
Spot should give a raster of 2.0x2.0mm or smaller. Change to the LH2
target. Again start at 25 microA on the 15 cm LH2. Expect singles
rates of 40 Khz at 25 microA.
Spectrometer settings:
| Spectrometer |
Momentum |
Angle |
Collimator |
| Right |
-2.981 GeV/c |
21.48° |
6msr |
| Left |
+1.893 GeV/c |
21.38° |
6msr |
Data taking
Change the
prescales back to what they were (as a starting point). Be sure the
trigger is properly loaded (it should be the same).
HALOG the settings (magnets, angles, prescales).
The prescales for
T1,T2,T3 and T4 should be set to give less than 10 Hz trigger rate for
each. T5 should be set to 1. The T8 prescale should be set to
maximum. HALOG the prescale values.
Need to
modify the header file :: hdr_kaon2
The data
taking time is estimated to be 4.0 hours. Will need to update by doing
a simultaneous replay.
Take a
short (15 minute) run at 25 uA then increase current to 75 uA and take
the rest of the data.
Take a
short (15 minute) run at 25 uA on the 15 cm empty
target.
Third setting
Kinematics:
The third setting
is at the Q2=2.35 (GeV/c)2, W=1.98 GeV, high
epsilon setting.
Settings: Change the
electron arm first then take a 5 minute single arm run with the
multifoil targets. Then change the hadron arm and take another 5
minute single arm run with the multifoil target.
Beam and Target:
Double check that fast feedback locks on both energy and orbit are on.
Spot should give a raster of 2.0x2.0mm or smaller. Change to the LH2
target. Again start at 25 microA on the 15 cm LH2.
Spectrometer settings:
| Spectrometer |
Momentum |
Angle |
Collimator |
| Right |
-2.719 GeV/c |
22.51° |
6msr |
| Left |
+2.266 GeV/c |
18.83° |
6msr |
Data taking
Change the
prescales back to what they were (as a starting point). Be sure the
trigger is properly loaded (it should be the same).
HALOG the settings (magnets, angles, prescales).
The prescales for T1,T2,T3
and T4 should be set to give less than 10 Hz trigger rate for each. T5
should be set to 1. The T8 prescale should be set to maximum. HALOG the
prescale values.
Need to
modify the header file : : hdr_kaon3
The data
taking time is estimated to be 4.0 hours. Will need to update by doing
a simultaneous replay.
Take a
short (15 minute) run at 25 uA then increase current to 75 uA and take
the rest of the data.
Take a
short (15 minute) run at 25 uA on the 15 cm empty
target.
Fourth setting
Kinematics:
The fourth
setting is at the Q2=2.35 (GeV/c)2, W=2.08 GeV,
high epsilon setting.
Settings: Change the
electron arm first then take a 5 minute single arm run with the
multifoil targets. Then change the hadron arm and take another 5
minute single arm run with the multifoil target.
Beam and Target:
Double check that fast feedback locks on both energy and orbit are on.
Spot should give a raster of 2.0x2.0mm or smaller. Change to the LH2
target. Again start at 25 microA on the 15 cm LH2.
Spectrometer settings:
| Spectrometer |
Momentum |
Angle |
Collimator |
| Right |
-2.504 GeV/c |
23.46° |
6msr |
| Left |
+2.542 GeV/c |
16.98° |
6msr |
Data taking
Change the
prescales back to what they were (as a starting point). Be sure the
trigger is properly loaded (it should be the same).
HALOG the settings (magnets, angles, prescales).
The prescales for T1,T2,T3
and T4 should be set to give less than 10 Hz trigger rate for each. T5
should be set to 1. The T8 prescale should be set to maximum. HALOG the
prescale values.
Need to
modify the header file : hdr_kaon4
The data taking time
is estimated to be 4.0 hours. Will need to update by doing a simultaneous
replay.
Take a short (15 minute)
run at 25 uA then increase current to 75 uA and take the rest of the data.
Take a short (15 minute)
run at 25 uA on the 15 cm empty target.
Fifth setting
Kinematics:
The fifth
setting is at the Q2=1.90 (GeV/c)2, W=1.94 GeV,
high epsilon setting.
Settings: Change the
electron arm first then take a 5 minute single arm run with the
multifoil targets. Then change the hadron arm and take another 5
minute single arm run with the multifoil target.
Beam and Target:
Double check that fast feedback locks on both energy and orbit are on.
Spot should give a raster of 2.0x2.0mm or smaller. Change to the LH2
target. Again start at 25 microA on the 15 cm LH2.
Spectrometer settings:
| Spectrometer |
Momentum |
Angle |
Collimator |
| Right |
-3.039 GeV/c |
19.11° |
6msr |
| Left |
+1.986 GeV/c |
20.29° |
6msr |
Data taking
Change the
prescales back to what they were (as a starting point). Be sure the
trigger is properly loaded (it should be the same).
HALOG the settings (magnets, angles, prescales).
The prescales for T1,T2,T3
and T4 should be set to give less than 10 Hz trigger rate for each. T5
should be set to 1. The T8 prescale should be set to maximum. HALOG the
prescale values.
Need to
modify the header file : hdr_kaon4
The data taking time
is estimated to be 4.0 hours. Will need to update by doing a simultaneous
replay.
Take a short (15 minute)
run at 25 uA then increase current to 75 uA and take the rest of the data.
Take a short (15 minute)
run at 25 uA on the 15 cm empty target.
Sixth through the Ninth settings
Kinematics:
The sixth,
seventh, eighth and ninth settings are the LT-interfence part. Call
in the Hall A "tech on call" halfway through the sixth measurement
to prepare for the small angle. Here the electron will stay fixed and
the hadron momentum will be constant between 6th and 7th settings and
the 8th and 9th.
Settings: Change the
electron arm first then take a 5 minute single arm run with the
multifoil targets. Then change the hadron arm and take another 5
minute single arm run with the multifoil target.
Beam and Target:
Double check that fast feedback locks on both energy and orbit are on.
Spot should give a raster of 2.0x2.0mm or smaller. Change to the LH2
target. Again start at 25 microA on the 15 cm LH2.
Spectrometer settings:
| Spectrometer |
Momentum |
Angle |
Collimator |
| Right |
-3.039 GeV/c |
19.11° |
6msr |
| Left |
+1.930 GeV/c |
14.67/25.91° |
6msr |
| Left |
+1.890 GeV/c |
12.69/27.88° |
6msr |
Data taking
Change the
prescales back to what they were (as a starting point). Be sure the
trigger is properly loaded (it should be the same).
HALOG the settings (magnets, angles, prescales).
The prescales for T1,T2,T3
and T4 should be set to give less than 10 Hz trigger rate for each. T5
should be set to 1. The T8 prescale should be set to maximum. HALOG the
prescale values.
Need to
modify the header file : hdr_kaon5, hdr_kaon6,
hdr_kaon7 or hdr_kaon8
appropriately.
The data
taking time is estimated to be 4.0 hours each for settings 5, 6 7, and
8. Will need to update by doing a simultaneous
replay.
Take a
short (15 minute) run at 25 uA then increase current to 75 uA and take
the rest of the data.
Take a
short (15 minute) run at 25 uA on the 15 cm empty
target for each setting.
Change to
angle 6, take the hydrogen data (again 4 hours) then switch to the
multifoil target and take 5 minutes at 10 uA. Repeat for settings 7 and 8.
Tenth setting
Kinematics:
The tenth
setting is at the Q2=1.90 (GeV/c)2, W=2.14 GeV,
high epsilon setting.
Settings: Change the
electron arm first then take a 5 minute single arm run with the
multifoil targets. Then change the hadron arm and take another 5
minute single arm run with the multifoil target.
Beam and Target:
Double check that fast feedback locks on both energy and orbit are on.
Spot should give a raster of 2.0x2.0mm or smaller. Change to the LH2
target. Again start at 25 microA on the 15 cm LH2.
Spectrometer settings:
| Spectrometer |
Momentum |
Angle |
Collimator |
| Right |
-2.608 GeV/c |
20.64° |
6msr |
| Left |
+2.521 GeV/c |
16.41° |
6msr |
Data taking
Change the
prescales back to what they were (as a starting point). Be sure the
trigger is properly loaded (it should be the same).
HALOG the settings (magnets, angles, prescales).
The prescales for T1,T2,T3
and T4 should be set to give less than 10 Hz trigger rate for each. T5
should be set to 1. The T8 prescale should be set to maximum. HALOG the
prescale values.
Need to
modify the header file : hdr_kaon4
The data taking time
is estimated to be 4.0 hours. Will need to update by doing a simultaneous
replay.
Take a short (15 minute)
run at 25 uA then increase current to 75 uA and take the rest of the data.
Take a short (15 minute)
run at 25 uA on the 15 cm empty target.
Eleventh setting
Kinematics:
The eleventh
setting is at the Q2=1.90 (GeV/c)2, W=2.00 GeV,
high epsilon setting.
Settings: Change the
electron arm first then take a 5 minute single arm run with the
multifoil targets. Then change the hadron arm and take another 5
minute single arm run with the multifoil target.
Beam and Target:
Double check that fast feedback locks on both energy and orbit are on.
Spot should give a raster of 2.0x2.0mm or smaller. Change to the LH2
target. Again start at 25 microA on the 15 cm LH2.
Spectrometer settings:
| Spectrometer |
Momentum |
Angle |
Collimator |
| Right |
-2.925 GeV/c |
19.52° |
6msr |
| Left |
+2.147 GeV/c |
19.03° |
6msr |
Data taking
Change the
prescales back to what they were (as a starting point). Be sure the
trigger is properly loaded (it should be the same).
HALOG the settings (magnets, angles, prescales).
The prescales for T1,T2,T3
and T4 should be set to give less than 10 Hz trigger rate for each. T5
should be set to 1. The T8 prescale should be set to maximum. HALOG the
prescale values.
Need to
modify the header file : hdr_kaon4
The data taking time
is estimated to be 4.0 hours. Will need to update by doing a simultaneous
replay.
Take a short (15 minute)
run at 25 uA then increase current to 75 uA and take the rest of the data.
Take a short (15 minute)
run at 25 uA on the 15 cm empty target.
Twelfth setting
Kinematics:
The twelfth
setting is at the Q2=1.90 (GeV/c)2, W=1.905 GeV,
high epsilon setting. Note we are at the limit of the electron arm dipole here.
Settings: Change the
electron arm first then take a 5 minute single arm run with the
multifoil targets. If there is any trouble with the electron arm
dipole phone John LeRose for help. Remember, this is the maximum
momentum for the right dipole. Then change the hadron arm and take
another 5 minute single arm run with the multifoil target.
Beam and Target:
Double check that fast feedback locks on both energy and orbit are on.
Spot should give a raster of 2.0x2.0mm or smaller. Change to the LH2
target. Again start at 25 microA on the 15 cm LH2.
Spectrometer settings:
| Spectrometer |
Momentum |
Angle |
Collimator |
| Right |
-3.110 GeV/c |
18.89° |
6msr |
| Left |
+1.890 GeV/c |
21.02° |
6msr |
Data taking
Change the
prescales back to what they were (as a starting point). Be sure the
trigger is properly loaded (it should be the same).
HALOG the settings (magnets, angles, prescales).
The prescales for T1,T2,T3
and T4 should be set to give less than 10 Hz trigger rate for each. T5
should be set to 1. The T8 prescale should be set to maximum. HALOG the
prescale values.
Need to
modify the header file : hdr_kaon4
The data taking time
is estimated to be 4.0 hours. Will need to update by doing a simultaneous
replay.
Take a short (15 minute)
run at 25 uA then increase current to 75 uA and take the rest of the data.
Take a short (15 minute)
run at 25 uA on the 15 cm empty target.
Thirteenth through the Sixteenth settings
Kinematics:
The 13th,
14th, 15th and 16th settings are again the LT-interfence part. Here the
electron will stay fixed and the hadron momentum will be constant
between 13th and 14th settings and the 15th and 16th. Call
in the Hall A "tech on call" halfway through the thirteenth measurement
to prepare for the small angle.
Settings: Change the
electron arm first then take a 5 minute single arm run with the
multifoil targets. Then change the hadron arm and take another 5
minute single arm run with the multifoil target.
Beam and Target:
Double check that fast feedback locks on both energy and orbit are on.
Spot should give a raster of 2.0x2.0mm or smaller. Change to the LH2
target. Again start at 25 microA on the 15 cm LH2.
Spectrometer settings:
| Spectrometer |
Momentum |
Angle |
Collimator |
| Right |
-2.925 GeV/c |
19.52° |
6msr |
| Left |
+2.068 GeV/c |
12.55/25.59° |
6msr |
| Left |
+2.104 GeV/c |
14.27/23.88° |
6msr |
Data taking
Change the
prescales back to what they were (as a starting point). Be sure the
trigger is properly loaded (it should be the same).
HALOG the settings (magnets, angles, prescales).
The prescales for T1,T2,T3
and T4 should be set to give less than 10 Hz trigger rate for each. T5
should be set to 1. The T8 prescale should be set to maximum. HALOG the
prescale values.
Need to
modify the header file : hdr_kaon5, hdr_kaon6,
hdr_kaon7 or hdr_kaon8
appropriately.
The data
taking time is estimated to be 4.0 hours each for settings 5, 6 7, and
8. Will need to update by doing a simultaneous
replay.
Take a
short (15 minute) run at 25 uA then increase current to 75 uA and take
the rest of the data.
Take a
short (15 minute) run at 25 uA on the 15 cm empty
target for each setting.
Change to
angle 6, take the hydrogen data (again 4 hours) then switch to the
multifoil target and take 5 minutes at 10 uA. Repeat for settings 7 and 8.