Meeting No4 - Threshold Pi0 beam energy determination
Energy losses:
I had to re-estimate energy losses for all three targets because in previous calculatios I considered Ti target
window instead of the Al one. Here are corrected results:
Carbon target:
Material | Thickness [cm]
---------------------------------------------
Carbon target | 0.0419
Aluminium window | 0.04064
Air | 65.1
Kapton window | 0.03556
Tantalum target:
Material | Thickness [cm]
---------------------------------------------
Tantalum target | 0.001213
Aluminium window | 0.04064
Air | 65.1
Kapton window | 0.03556
Hydrogen target:
Material | Thickness [cm]
---------------------------------------------
Aluminium | 0.0127
Hydrogen target | 6.0
Aluminium | 0.0127
Aluminium window | 0.04064
Air | 65.1
Kapton window | 0.03556
In the end we got following estimations for the energy losses:
Target | Energy Loss [MeV]
------------------------------------
Hydrogen | 1.64 - 1.68
Carbon | 0.43
Tantalum | 0.35
DB - files
I have checked which DB are we using. At the moment we are using the DB from the
beginning of the Pi0 experiment: 20080402
Spectrometer Constant (pc) and Nilanga's formula
In this analysis we didn't use spectrometer constant from EPICS any more. We have calculated
it from magnetic field, using Nilanga's polynomial formula. Following plots show difference
between the central momenta from EPICS entries and Nilanga's formula:
Magnetic field:
Central Momentum:
Fitting Results:
Here are our latest fitting results. We have done two types of fits:
1.) we fitted elastic points as a function of the scattering angle at fixed mass.
2.) we fitted elastic points as a function of target mass at fixed scattering angle.
Here are the results:
Angle Fit:
Hydrogen:
NO. NAME VALUE ERROR NEGATIVE POSITIVE
-------------------------------------------------------------------------
1 E0 1.19199e+03 2.08205e-01
NO. NAME VALUE ERROR NEGATIVE POSITIVE
-------------------------------------------------------------------------
1 E0 1.19222e+03 5.59762e-02
Carbon:
NO. NAME VALUE ERROR NEGATIVE POSITIVE
-------------------------------------------------------------------------
1 E0 1.19315e+03 2.79028e-01
NO. NAME VALUE ERROR NEGATIVE POSITIVE
-------------------------------------------------------------------------
1 E0 1.19309e+03 1.17873e-01
Tantalum:
NO. NAME VALUE ERROR NEGATIVE POSITIVE
-------------------------------------------------------------------------
1 E0 1.19336e+03 1.60159e-01
Mass Fit:
1st Series:
NO. NAME VALUE ERROR NEGATIVE POSITIVE
---------------------------------------------------------------------------
1 E0 1.19373e+03 1.91058e-01
2nd Series:
NO. NAME VALUE ERROR NEGATIVE POSITIVE
---------------------------------------------------------------------------
1 E0 1.19452e+03 2.60247e-01
3rd Series:
NO. NAME VALUE ERROR NEGATIVE POSITIVE
---------------------------------------------------------------------------
1 E0 1.19256e+03 3.22166e-01
Analyzed data:
Here are momentum distribution plots (variable L.gold.dp) for all the analyzed runs.
1.) Tantalum Runs:
2356:
2874:
2875:
2876:
2877:
2883:
3108:
3109:
3111:
4388:
4517:
4644:
4671:
4672:
4755:
2.) Carbon Runs:
2884:
3112 + 3113 + 3130:
4389:
4391:
4518:
3.) Hydrogen Runs:
2360:
2361:
2885:
3135:
3136:
4392:
4395:
4519:
4646:
4647:
4674:
4756:
4757:
Last modified: 08/04/09