Privacy and Security Notice
Bending of the electron beam in the Moller polarimeter because of Helmholtz coils rotation .
Moller Quads are Turned ON : Q1=1.46 Q2=0 Q3=0.29 Dipole=1.49
| Coils | Beam | Beam shift at the distance from target | Beam shift at the distance from target |
| Rotation | Shift | 5.5m | 9.0m | 14.0m | 5.5m | 9.0m | 14.0m |
| around | direction | cm/mrad | cm/mrad | cm/mrad | cm/m*mrad | cm/m*mrad | cm/m*mrad |
| X | X | +0.09 | +0.14 | +0.22 | +0.016 | +0.016 | +0.016 |
| X | Y | +0.07 | +0.11 | +0.17 | +0.013 | +0.012 | +0.012 |
| Y | X | +0.03 | +0.06 | +0.09 | +0.006 | +0.007 | +0.006 |
| Y | Y | -0.23 | -0.40 | -0.65 | -0.042 | -0.044 | -0.046 |
Bending of the electron beam in the Moller polarimeter because of Helmholtz coils shift .
Moller Quads are Turned ON : Q1=1.46 Q2=0 Q3=0.29 Dipole=1.49
| Coils | Beam | Beam shift at the distance from target | Beam shift at the distance from target |
| Shift | Shift | 5.5m | 9.0m | 14.0m | 5.5m | 9.0m | 14.0m |
| along | direction | cm/mm | cm/mm | cm/mm | cm/m*mm | cm/m*mm | cm/m*mm |
| X | X | +0.04 | +0.07 | +0.12 | +0.007 | +0.008 | +0.009 |
| X | Y | +0.18 | +0.31 | +0.50 | +0.033 | +0.034 | +0.038 |
| Y | X | -0.11 | -0.19 | -0.32 | -0.020 | -0.021 | -0.023 |
| Y | Y | +0.10 | +0.17 | +0.26 | +0.018 | +0.019 | +0.019 |
| X+Y | X | -0.09 | -0.17 | -0.28 | -0.016 | -0.019 | -0.020 |
| X+Y | Y | +0.24 | +0.42 | +0.68 | +0.044 | +0.046 | +0.049 |
Bending of the electron beam in the Moller polarimeter because of Helmholtz coils rotation .
Moller Quads are Turned OFF
| Coils | Beam | Beam shift at the distance from target | Beam shift at the distance from target |
| Rotation | Shift | 5.5m | 9.0m | 14.0m | 5.5m | 9.0m | 14.0m |
| around | direction | cm/mrad | cm/mrad | cm/mrad | cm/m*mrad | cm/m*mrad | cm/m*mrad |
| X | X | +0.14 | +0.23 | +0.35 | +0.02 | +0.026 | +0.025 |
| X | Y | +0.03 | +0.04 | +0.07 | +0.055 | +0.0044 | +0.005 |
| Y | X | +0.03 | +0.04 | +0.07 | +0.0055 | 0.0044 | 0.005 |
| Y | Y | -0.14 | -0.23 | -0.35 | -0.02 | -0.026 | -0.025 |
Bending of the electron beam in the Moller polarimeter because of Helmholtz coils shift .
Moller Quads are Turned OFF
| Coils | Beam | Beam shift at the distance from target | Beam shift at the distance from target |
| Shift | Shift | 5.5m | 9.0m | 14.0m | 5.5m | 9.0m | 14.0m |
| along | direction | cm/mm | cm/mm | cm/mm | cm/m*mm | cm/m*mm | cm/m*mm |
| X | X | +0.055 | +0.08 | +0.12 | +0.010 | +0.009 | +0.009 |
| X | Y | +0.125 | +0.22 | +0.35 | +0.023 | +0.024 | +0.025 |
| Y | X | -0.125 | -0.22 | -0.35 | -0.023 | -0.024 | -0.025 |
| Y | Y | +0.055 | +0.08 | +0.12 | +0.010 | +0.009 | +0.009 |
| X+Y | X | -0.09 | -0.16 | -0.23 | -0.016 | -0.017 | -0.016 |
| X+Y | Y | +0.17 | +0.28 | +0.44 | +0.031 | +0.031 | +0.031 |
| X+Y | X for 1Tl | -0.035 | -0.055 | -0.085 | -0.006 | -0.006 | -0.006 |
| X+Y | Y for 1Tl | +0.040 | +0.060 | +0.095 | +0.007 | +0.007 | +0.007 |