The electronics and DAQ was installed in 1998 and used up to 2008 with only slight modifications. The lead glass calorimeter was replaced in 2000, by a SPACAL-type calorimeter.
| Step | Module | Signals | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| function | type | bandwidth | pulse | channels | comment | input | output | comment | ||||
| step | cable | max rate | pulse | max rate | ||||||||
| 1 | Linear fan-out | P/S 748 | 250 MHz | 8 | Cal 1-8 | - | - | 20 ns | - | |||
| 2 | Linear fan-out | P/S 740 | 250 MHz | 4 | 1 | 1 ns | - | 20 ns | - | 4L, 4R | ||
| 3 | Discriminator | Ortec TD8000 | 100 MHz | τ>5 ns | 8 | blocking mode | 2 | 8 ns | - | 8 ns | 1 MHz | ΣL, ΣR |
| Apert 1-2 | - | - | 8 ns | 3 MHz | ApL, ApR | |||||||
| 4 | Delay unit | LeCroy 4518 | 100 MHz | τ>5 ns | 16 | double >10 ns | 3 | 2 ns | 3 MHz | 8 ns | 3 MHz | ΣL, ΣR, ApL, ApR |
| 5 | PLU | LeCroy 2365 | 75 MHz | τ>7 ns | 16 | 8 outputs | 4 | 2 ns | 3 MHz | 8 ns | 1 MHz | Coincidences, BCM etc |
| 6 | Scaler | LeCroy 1151E | 80 MHz | τ>5 ns | 16 | 5 | 2 ns | 1 MHz | - | - | Coincidences, BCM etc | |
| 7 | TDC | LeCroy 2277 | 80 MHz | 1 ns bin | 32 | double >20 ns | 4 | 2 ns | 3 MHz | - | - | ΣL, ΣR, ApL, ApR |