Privacy and Security Notice

Target Measurements

Target Polarization Measurements


The polarization of the target foils was measured by measuring the magnetic flux through the foil.


Foil Reference

The following table contains the parameters of the foils considered. Some of these foils have been characterized. A detailed summary of the foil dimensions, weights etc can be found in this PS file

Parameters of the foils
Foil Material Manufactured Annealed Sizes, mm Weight Mean Pol plots in use Comment
# name Type from where how where toC time, h thick width length g % B Gs % B Gs exp when now
1 SA51M SM vacoflux48 KIPT roll KIPT ? ? ~0.050 30. 360 4.383 8.205 530 8.017 92.7 1 2 3 E158 01-07, 2002 JLab Re-measured at JLab
2 SLAC201 SM vacoflux? Vacofl roll SLAC ? ? 0.01938 30.02 364 1.719 8.239 530 8.191 92.7 1 2 E158 01-12, 2002 JLab Re-measured at JLab
3 S96 SM vacoflux48 KIPT roll KIPT 880 3+4 0.09675 30.33 359.4 8.564 8.343 530 8.096 92.7 1 2 3 4 5 6 E158 01-07, 2002 JLab Re-measured at JLab
4 SLAC401 SM vacoflux? Vacofl roll SLAC ? ? 0.03939 30.2 364 3.516 8.216 530 8.147 94 1 2 3 4 E158 07-__, 2002 SLAC -
5 SCC701 SM vacoflux48 KIPT roll KIPT 880 3+4 0.09921 30.28 359.5 8.768 8.296 530 7.680 92.7 1 2 3 3a 4 E158 07-12, 2002 JLab Re-measured at JLab
6 S20 SM Germany Germany roll Germany ? ? ~0.020 30.0 363.5 1.687 8.160 586. 8.117 90 1 2 E158 01-12, 2003 JLab Measured at JLab
7 S98 SM vacoflux48 KIPT roll KIPT ? ? 0.098 30 360 8.614 8.290 586 8.077 90.0 1 2 E158 01-12, 2003 JLab Measured at JLab
8 SLAC402 SM vacoflux? ? roll ? ? ? ~0.0403 30.1 363.95 3.585 8.29 530 8.09 100 1 2 3 4 - - JLab -


Last modified: Thu Jun 5 17:51:43 EDT 2003
E-Mail: Eugene Chudakov