Privacy and Security Notice

Target Measurements

Target Polarization Measurements


The polarization of the supermendur foils was measured by motor scanning of the magnetic flux through the foil.


Foil Reference

The following table contains the parameters of the foils considered. Some of these foils have been early installed at SLAC Moller polarimeter and were recalibrated. A detailed summary of the foil dimensions, weight, polarization values for different magnetizing fields are listed in Table.

Parameters of the foils
Foil Material Manufact Anneal. Size, mm
Weight Polariz. in center Plots Data
in use Comment
# name Type from where where
thick width length g % B, Gs % B, Gs exp now
1 Sa51m SM vacoflux48 KIPT KIPT
0.0498
30. 360. 4.383 8.148 553 7.797
91.9 1,2,3
1
E158 SLAC
Re-measured at JLab
2 S98 SM vacoflux48 KIPT KIPT
0.0979 30. 360.0 8.614 8.294 553 7.943
91.8 1,2,3
1
E158
SLAC
Re-measured at JLab
3 S96 SM vacoflux48 KIPT KIPT
0.0968 30.33 359.4 8.564 8.302 586 7.927 91.7 1,2,3
1
E158
SLAC
Re-measured at JLab
4
Scc701
SM
vacoflux48
KIPT
KIPT
0.0992
30.28
359.5
8.768
8.287
586
7.445
91.8
1,2,3
1
E158
JLab
Re-measured at JLab
5
S201*
SM
Germany
Germany
Germany
0.0194
30.02
352.0*
1.719?
8.183
586
8.090
91.9
1,2,3
1
E158
JLab
Re-measured at JLab
6 S20 SM Germany Germany Germany
0.0190
30.0 363.5 1.687 8.248
553 8.188
91.7 1,2,3
1

JLab Measured at JLab
7
S30 SM Germany Germany Germany
0.0294
30.0 363.5 2.612 8.246
549 8.236
91.1 1,2,3
1
- JLab Measured at JLab
8
S40 SM Germany Germany Germany
0.0401
30.0 363.5 3.567 8.343
578. 8.226
90.6 1,2,3
1
- JLab Measured at JLab
* S201 was cutted at SLAC. Now the foil length is 352mm instead of 363.5mm

Foil polarization in the beam position

#
Foil
P, %
B, Gs
P, %
B, Gs
P, %
B, Gs
1
Sa51m
7.901
91.9
8.069
195.8
8.172
553.5
2
S98
-
-
-
-
-
-
3
S96
7.841
91.7
8.201
195.8
8.297
585.9
4
Scc701
7.575
91.8
8.042
195.8
8.287
585.9
5
S201
8.083
91.9
8.138
195.8
8.162
586.2
6










Last modified: Mon Jul 14 11:06:28 EDT 2003