Privacy and Security Notice

 
 

Jefferson Lab Experiment E91-016

H2(e,e'K+), +15% delta scan

Item Task Log Entry
  For a beam energy of 3.245 GeV set the spectrometers to:
  Momentum (GeV/c) Angle (degree) Trigger Collimator Prescaling
HMS -1.425 15.00 e--PID pion PS1=
SOS +1.290 13.30 K+-PID large PS2=
Follow the proper prodecures for setting the magnets (if not done yet):
  • HMS current&field settings: 
    •  cdaqs1> ~cdaq/FIELD/field99
       Input HMS momentum in GeV, electron is negative.
      -1.425
       Set current for Q1 =     185.00952510844 amps
       Set current for Q2 =    -147.00558385297 amps
       Set current for Q3 =     72.196281624747 amps
       Set NMR for Dipole =   -0.39049801783945 Tesla


    Set HMS Quads 200 A above required setting and then go down to nominal setting

  • Degauss SOS for protons and then go up to nominal setting
 
  Ask for 10 uA beam. Determine SOS 3/4 rate and then increase current such as to give 600kHz SOS 3/4 rate. 30 uA should be possible.  
  Take a short run. Adjust prescale factors such that HMS and SOS singles rates are approx. 5% each. Determine deadtime for this setting.  
Take runs with 1M triggers.  
Hall C Operating Manual
Last updated 11/19/99
By Jörg Reinhold(reinhold@fiu.edu)