Basic Components
6.5 l LH2 cell & re-circulation loop
Re-circulation fan/pump (30 Hz)
500 W (max) heater (on PID) to replace Pbeam
500 W (Helium) heat exchanger
He Supply ~ 15K, 15 atm
He Return ~ 19K, 3 atm
JT controller on He Supply
T&P instrumentation
Control System
Gas Panel, Ballast tank, Electronics